24
DVRTSB Bay Window Fireplace
10003848
LG298
Fig. 39
DVRTSB logs.
B105
B110
B106
B108
B109
B107
LG299
Ceramic Ember Rock Location
Fig. 40
Location of log cradle prongs in relation to assembled logs.
Flame & Temperature Adjustment
RN/RP Models
For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustments knob located near the center of the gas
control valve. (Figs. 41 & 42)
��
��
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99 djt
Fig. 41
Flame adjustment knob for Honeywell valve.
LO
HI
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 42
Flame adjustment knob for SIT valve.
Lava Rock & Ember Material
Your log set contains two types of “Lava Rocks”.
The placement of this material is best done after the
logs have been installed.
Ceramic Ember Rocks
(Pt. # 57897)
Remove these ‘rocks’ from the packaging and spread
them over the burner tiles in a random fashion to fill
up the spaces between the logs. (Fig. 40) Only place
ceramic embers in areas shown in Figure 40.
Lava Rock
(Pt.# 10001454)
Remove this material from the packaging and spread
it over the ceramic floor panels outside the log stack.
DO NOT PLACE THIS MATERIAL ON THE BURNER
TILES.