Majestic BR36 Operating Manual Download Page 1

BR/BC Series

Woodburning Fireplace

For Models:

  BR36
  BR42
  BC36
  BC42

For use in U.S./Canada
Underwriter's Laboratories Report No. MH6018

DO NOT DISCARD THIS MANUAL:  Retain for future use.

Homeowner's Installation and Operating Manual

7412944  5/04  Rev. 15

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

CFM Specialty Home Products

Summary of Contents for BR36

Page 1: ...riter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use Homeowner s Installation and Operating Manual 7412944 5 04 Rev 15 410 Admiral Blvd Mississauga Ontario Canada L5T...

Page 2: ...t manufactured or approved by CFM Spe cialty Home Products in combination or assem bly with a Majestic Fireplaces fireplace system notwithstanding any independent testing laboratory or other third par...

Page 3: ...8 Dia 203mm 3 2 8 2 2 m m If elbows are offset to the back of the unit chase depth will be 22 575mm FP527 Fig 2 BC36 Series specifications and framing BC36 Series Woodburning Fireplace Circulating Mod...

Page 4: ...r Gas Line Access Electrical Access 1194mm 8 Dia 203mm 3 5 8 9 5 m m If elbows are offset to the back of the unit chase depth will be 22 575mm BR42 Series Woodburning Fireplace Fig 3 BR42 Series speci...

Page 5: ...g 5 Fireplace and chase parts identification Termination Cap Storm Collar Pan Flashing Draftstop Standoff Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips...

Page 6: ...y exit BR BC36 BR BC42 Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return to...

Page 7: ...e the reference point but never less than 3 914mm in height above the highest point where it passes through the roof Determine how the chimney will be run length of run and chimney components required...

Page 8: ...place location or how the chimney system should be run contact your Majestic Fireplaces dealer for assistance If you live in a cold climate it is not required but highly recommended that you insulate...

Page 9: ...cured complete wiring the fan kit Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately 6 159mm of...

Page 10: ...he ceiling joists this is a requirement at attic level Offset Installation In order to clear an obstruction it may be necessary to offset chimney from vertical This is accomplished by using CFM Corpor...

Page 11: ...ngth to the metals strips provided with the fireplace Note Safety strips are not required over noncombus tible floors where all supports at the base of the fire place are noncombustible Four 4 nailing...

Page 12: ...re 13 for angled firestop spac ers provide minimum required air space to chimney pipe for ceiling thickness up to 8 203mm When combined thickness of ceiling material ceiling joists and flooring materi...

Page 13: ...ncounter additional ceilings repeat same steps required for first ceiling installation See firestop illustration on Page 12 Figure 18 Penetrating the Roof Run pipe to roofline Since chimney system mus...

Page 14: ...Wall Finish the wall with material of your choice Do not install a combustible mantel shelf less than 12 305mm from the top of the fireplace opening for radiant models and 12 305mm from top of grille...

Page 15: ...59mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Material...

Page 16: ...sion material Fig 23 Secure the hearth extension to the floor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the fireplace hearth and hearth ex...

Page 17: ...ctors are related by the formula K 1 R Fig 24 T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided th...

Page 18: ...rough opening After gas pipe installation is complete use insulation that was removed from gas line tube to repack space around the pipe Material should be inserted from outside of the fireplace and p...

Page 19: ...3032103 or 20007496 6b Firebrick Rear 3030102 or 20007495 3032102 or 20007497 6c Firebrick Rt Side 3030160 or 20007492 3030160 or 20007492 6d Firebrick Lt Side 3030104 or 20007493 3030104 or 20007493...

Page 20: ...ty In addition such action may void the coverage provided by the owner s insur ance Accessories Contact your Majestic Fireplaces distributor or dealer for finishing Marble and Mantels available in a w...

Page 21: ...imney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid sty...

Page 22: ...tion Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chi...

Page 23: ...ect to the following conditions and limita tions 1 This warranty is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fi...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...