74D3001
9
DVBL7
Series Gas Fireplace
cLearanceS
cLearanceS to comBuStIBLeS
Figure 4 -
Clearances From The Mantel, Ceiling,
and Side Wall
w
arn
In
G
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
the appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
71” Minimum
Ceiling
13” Min.
From Opening
12” Max.
Depth
6”
Min.
FP2333
BLDV mantel clear
FP333
45°
1”
2
56O
”
3”
5”
1
56O
”
6”
3
56O
”
4
56O
”
FP2334a
BLDV side leg clear
Figure 4a -
Mantel Clearances
Side of Fire-
place Opening
Wall
Combustible
Material Area
FP334a
top View
2
56M
” Max.
1
56O
” Max.
7
56O
”
Min.
13”
Min.
12” Max.
FP2904
mantel w eyebrow
Combustible
Breastplate
3/4" Marble
Eyebrow Canopy
Figure 4b -
Mantel Clearance with Eyebrow Canopy
note:
When eyebrow canopy is used, minimum clearance
to combustibles is
Z\v
" maximum out from fireplace front
at 7
Z\x
" minimum from opening.
Figure 4b.
When eyebrow
is not used, clearances to combustibles is 1" maximum
out from fireplace front at 13" minimum from opening.
Figure 4