Majestic fireplaces NVCVR36 Installation And Operating Manual Download Page 14

NVSTR/ NVCVR Series 

14

7412958

Lighting and Operating Instructions

     

 

 

For Fireplaces equipped with SIT822 Gas Valve (EN or EP)

A.  This fireplace is equipped with an ignition device 

which automatically lights the pilot. 

DO NOT

 try to 

light the pilot by hand.

B. BEFORE OPERATING,

 smell all around the  

appliance area for gas. Be sure to smell next to  
the floor because some gas is heavier than the air  
and will settle on the floor.

What to do if you smell gas

• 

Do not try to light any appliance

• 

Do not operate any electrical switch.

• 

Do not use any phone in your building.

• 

Immediately call your gas supplier from a  

FOR YOUR SAFETY READ THE FOLLOWING WARNINGS 

BEFORE LIGHTING THE APPLIANCE

1.  STOP! 

Read the safety information above before 

continuing.

2.  Turn off all electrical power to the appliance.
3.  This appliance is equipped with an ignition device 

which  automatically lights the pilot. 

DO NOT

 try to 

light the pilot by hand.

4.  Access the gas control by lowering the lower 

access door (louvre assembly).

neighbor’s phone. 

Follow the gas suppliers instructions.

• 

If you cannot contact your gas supplier call 
the Fire Department

C. Use only your hand to push in or turn the gas control 

knob. Never use tools. If the knob will not push in 
or turn by hand do not try to repair it, call a qualified 
service technician. Force or attempting repair may 
result in a fire or explosion.

D. Do not use this appliance  if any part has been under 

water. Immediately call a qualified service technician 
to inspect the appliance and replace any part of the 
control system and any gas control that has been 
under water.

5.  Turn the remote switch, if used, OFF. Turn the 

wireless remote, if used, OFF.

6.  Wait five (5) minutes to clear out any gas. Then 

smell for gas, including near the floor. If you smell 
gas STOP. Follow instructions B in the safety 
warnings above. If you do not smell gas go onto the 
next step.

7.  Close the access door.
8.  Turn ON all electrical power to the appliance.
9.  Turn remote switch or wireless remote to “ON”.
10. If the appliance will not operate, follow the 

instructions TURNING OFF THE GAS TO THE  
APPLIANCE and call your service technician or  
gas supplier.

1.  Turn the remote switch to the “OFF” position.
2.  Turn OFF all electrical power to the fireplace if  

service is required.

3  Open the lower access panel.
4.  Turn the shut-off valve on the flexible gas line to the 

“OFF” position.

Warning:If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury and loss of life.

Lighting Instructions

Turning Off the Gas to the Appliance

HI

LO

Valve in the "ON" position

GF598

nvb GAS SUPPLY INSTALL

12/4/97

1/2" Gas Supply

1/2" x 3/8" Shut-off Valve

3/8" Nipple

3/8" Union

3/8" 
Nipple

Summary of Contents for NVCVR36

Page 1: ...y a quali ed installer service agency or the gas supplier Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY if you smell...

Page 2: ...sion 5 Insulating for Cold Climates 5 Framing and Finishing 6 Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Gas Line Ins...

Page 3: ...combustion and ventilation air must not be obstructed in any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appliance must...

Page 4: ...Flange 6 DIA Rough Opening Width 41 1041mm Rough Opening Depth 3 90mm NVSTR36 Series Gas Appliance See Through Model 36 914mm 36 914mm 40 1029mm 3 79mm 21 533mm 40 1029mm 191mm 165mm 191mm 8 203mm Ou...

Page 5: ...533 mm Y 8 203 mm D 19 483 mm Z 1 38 mm E 15 381 mm Top of Combustion Chamber CFM146a Fig 3a Combustible mantel minimum installation J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta CFM170 D...

Page 6: ...supplied with the NVSTR replace found on the replace hearth Four 4 nailing anges are supplied with the NVCVR replace To level the box and secure it rmly in place remove the nailing anges from the hear...

Page 7: ...p Storm Collar Pan Flashing Draftstop Batt Insulation cut out around restop Firestop Ceiling Level Header Standoff Surround Screen Grate Firebox Valve Cover Plate Electrical Access Outside Air Cover P...

Page 8: ...ci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside of the appliance Fig 6 Remote Wall Switch 1 Thread wire through the electrical knockout located on side o...

Page 9: ...letely within the EB1 Attach the cov erplate to the replace Fig 9 Install the Venting System Flashing and Termination See venting installation instructions provided by the B Vent manufacturer Refer to...

Page 10: ...the vent system using a maximum of two 45 degree elbows FP567a Fig 12 Venting con gurations when installing 36GSKBB FP567 NVBR NVBC VENTING RUNS 11 12 97 rev 8 21 02 rjs Venting Runs 40 38 36 34 32 30...

Page 11: ...plastic items these logs are not toys and should be kept away from children and infants 3 Place rear log on back bracket Ensure that log is rmly positioned and there is no side to side move ment 4 Pl...

Page 12: ...g the Venting System The appliance venting system was designed and con structed to develop a positive ow adequate to remove ue gases to the outside atmosphere Any foreign objects in the venting system...

Page 13: ...ostat to desired setting 14 Turn on all electrical power to the replace WARNING If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or...

Page 14: ...by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re or explosion D Do not use this appliance if any part has been under water Immediately...

Page 15: ...rmodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot met...

Page 16: ...ions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay rep...

Page 17: ...top of the burner Check to make sure that burner parts are clean Visually inspect pilot Brush or blow away any dust or lint accumulation If pilot ori ce is plugged disassembly may be required to remo...

Page 18: ...R36 from FP397 FP578 replacement parts 4 30 98 rev 9 23 02 new name rjs 12a b 24a b 25a b 26 28 THTP TP TH 8 5a b 21 20 23 22 MV MVPV PV GND BURNER 24V 24V SENSE SPARK 29 30 27 7 10 6 9 11 4a b 3a b 2...

Page 19: ...080123 16 Ceramic Panel Left 3080122 16a Ceramic Panel Left 3079139 17 Ceramic Panel Right 3080121 17a Ceramic Panel Right 3079138 18 Ceramic Panel 3080125 19 Ceramic Panel 3080124 20 Door Track Black...

Page 20: ...nce model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Corporation 410 Admiral Blvd Mississauga Ontario...

Page 21: ...o installation instructions provided with the Outside Air Kit Thermal Vent Damper Installing the TVD6 7 Thermal Vent Damper reduces cold air in ltration when replace is not in use by open ing and clos...

Page 22: ...NVSTR NVCVR Series 22 7412958...

Page 23: ...age is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: