 NVB Series B-Vent

7412950

Optional Accessories

Fan Kit

The FK12 fan kit is available for use on the NVBC36
and NBVC42 model appliances only.

Auxiliary fan systems increase the efficiency of the
circulation of the heating air. The FK12 fan assembly is
a fixed speed fan system and does not allow for vari-
able speed control.

Installation

Remove the 2 ceramic fiber refractory panels by
carefully lifting them out of the fireplace. Next, remove
the access panel by  pulling it up and out from the side
edge of the panel. Use caution — the panel edges may
be sharp.

Center the fan assembly over the mounting location
and secure it with the Velcro

®

 strips at the back of the

fireplace.

Insert the plug into the receptacle (EB1) located
against the lower right side wall of the fireplace.

Caution: Be sure that no wires are pinched.

Prior to reinstalling the access panel and the hearth
brick, it is advisable to operate the wall switch on and
off to assure fan operation.  If the fan does not operate
and you are assured that 115 VAC power is present at
the receptacle, contact your Dealer.

Reinstall the access panel and hearth brick by revers-
ing Step 1.

WARNING: Never contact blower wheels during
operation.

Speed Control

The SCVS variable speed control is available to allow
speed adjustment of the fan.

Electrical Connection

The EB-1 electrical junction box is available for use with
the fan kits. The EB-1 is standard on the electronic
ignition models.

Glass Doors

Bi-fold and single panel glass doors are available to
enhance the viewing of the fireplace.

Appliance Models

Glass Doors

NVBR36/NVBC36

36GSKBB

36GDKBB
36GDKBK
36GDKDP

36GDKS

Appliance Models

Glass Doors

NVBR42/NVBC42

42GSKBB

42GDKBB
42GDKBK

42GDKDP

42GDKS

Outside Air Kit

The Model AK-MST Outside Air Kit is designed to bring
additional combustion air directly from the outside to
the fireplace. Refer to installation instructions provided
with the Outside Air Kit.

Thermal Vent Damper

Installing the TVD6/7 Thermal Vent Damper reduces
cold air infiltration when fireplace is not in use by
opening and closing automatically.

Attach the  thermal vent damper to the combustion
dome with 2 screws. Be sure the tab points down. (Fig.
21)

Start the appliance and operate it for approximately 5
minutes. Turn the unit off and check if the vent damper
is in the open position (blades down from the horizontal
position). If the damper has not opened, check installa-
tion.

Fig. 21  Attach the thermal vent damper.

FP577

Tab

Thermal Vent Damper

Screws

Remote Controls

Optional remote control units are available to control
different functions of the appliance.

Model

Function/s Controlled

MRC1

“ON/OFF”

MRC2

“ON/OFF” and Temperature

MRC3

“ON/OFF” and Temperature control
with a digital and a programmable 24
hour clock

Summary of Contents for NVBC42

Page 1: ...service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance...

Page 2: ...to Combustibles 6 Mantels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Specifications 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Id...

Page 3: ...lled directly on carpet ing vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 12 This...

Page 4: ...521mm 22 559mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series specification and framing dimensions NVBC36 Series Gas Appliance Circul...

Page 5: ...lectrical Access Gas Line Access Rough Opening Height 16mm 8 213mm 20 508mm 20 521mm 28 711mm Recessed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig...

Page 6: ...Opening F 14 356mm K 14 356mm G 12 305mm L 12 305mm H 10 254mm M 10 254mm I 8 203mm N 8 203mm J 1 38mm O 1 38mm Black Surround Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installation Sid...

Page 7: ...ivolt Hi Lo 30 000 21 500 NVBR36RP Propane Millivolt Hi Lo 30 000 22 000 NVBC36RP Propane Millivolt Hi Lo 30 000 22 000 NVBR36EN Natural Electronic Ignition 30 000 21 500 NVBC36EN Natural Electronic I...

Page 8: ...ts individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa If gas piping from the so...

Page 9: ...easily disconnected for burner or fan servicing See gas specification for pressure details and ratings NOTE If flex connector is used it must be kept inside of the appliance Fig 8 FP598 Fig 8 Typical...

Page 10: ...e of the EB1 while being careful to position excess wire completely within the EB1 Attach the coverplate to the fireplace Fig 11 Fig 11 Junction box EB 1 hook up FP580 Outside Electrical Box Front Of...

Page 11: ...tem using a maximum of two 45 degree elbows B Acceptable venting configuration Unacceptable venting configuration FP567a Fig 14 Venting configurations when installing 36GSKBB 40 38 36 34 32 30 28 26 2...

Page 12: ...deposit a slight film on the glass It is therefore recommended that the glass be cleaned two or three times with a non ammonia household cleaner and warm water we recommend gas fireplace glass cleane...

Page 13: ...ss this moisture disappears in a few minutes of burning Flame Adjustment For units equipped with Hi Lo valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the ce...

Page 14: ...these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF...

Page 15: ...the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempting repair may result in a fire or explos...

Page 16: ...nections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV...

Page 17: ...Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas...

Page 18: ...ost of these components may require only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a qualified technician In order to proper...

Page 19: ...3867 20003909 2 Lava Rock Package 20000376 20000376 3 Bag of Embers 7060109 7060109 4 Burner Housing w Tile 20003791 20003953 5 Ceramic Tile single 57803 57803 6a Burner Orifice Natural Manifold Orifi...

Page 20: ...ot Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 A...

Page 21: ...speed adjustment of the fan Electrical Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic ignition models Glass Doors Bi fold an...

Page 22: ...c Fireplaces NVB Series B Vent 7412950 Shrouds Decorative shrouds are available to enhance the appearance of the termination cap Square Shroud SSKDKU Pagoda Shroud PSKDKU Bishop Shroud BSKDKU TT Shrou...

Page 23: ...f upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provis...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic Products...

Reviews: