Majestic fireplaces NVBC42 Installation & Operation Instructions Download Page 1

Decorative Gas Appliances

INSTALLER: DO NOT DISCARD THIS MANUAL - Leave in fireplace for homeowner.

PLEASE READ THIS MANUAL

BEFORE INSTALLING AND

USING APPLIANCE.

IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation.
Failure to follow these instruc-
tions may result in a possible
fire hazard and will void the
warranty.

WARNING: If the information in
this manual is not followed
exactly, a fire or explosion may
result causing property dam-
age, personal injury or loss of
life.

FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency, or the
gas supplier. Do not store or
use gasoline or other flam-
mable vapors and liquids in the
vicinity of this or any other
appliance.

FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Do not touch electrical

switches.

3. Do not try to light any appli-

ance.

4. Extinguish any open flame.
5. Do not use the phone in

your building.

6. Immediately call your gas

supplier from a neighbor's
phone.

7. Follow your gas supplier's

instructions.

8. If you cannot reach your gas

supplier, call the fire depart-
ment.

INSTALLER/CONSUMER

SAFETY INFORMATION

Models: NVBR36, NVBC36

NVBR42, NVBC42

Homeowner's Installation and

Operating Manual

DESIGN

CER

TIFIE D

7412950  9/03  Rev.  12

NVBR36

NVBC42

950

Summary of Contents for NVBC42

Page 1: ...service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance...

Page 2: ...to Combustibles 6 Mantels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Specifications 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Id...

Page 3: ...lled directly on carpet ing vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 12 This...

Page 4: ...521mm 22 559mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series specification and framing dimensions NVBC36 Series Gas Appliance Circul...

Page 5: ...lectrical Access Gas Line Access Rough Opening Height 16mm 8 213mm 20 508mm 20 521mm 28 711mm Recessed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig...

Page 6: ...Opening F 14 356mm K 14 356mm G 12 305mm L 12 305mm H 10 254mm M 10 254mm I 8 203mm N 8 203mm J 1 38mm O 1 38mm Black Surround Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installation Sid...

Page 7: ...ivolt Hi Lo 30 000 21 500 NVBR36RP Propane Millivolt Hi Lo 30 000 22 000 NVBC36RP Propane Millivolt Hi Lo 30 000 22 000 NVBR36EN Natural Electronic Ignition 30 000 21 500 NVBC36EN Natural Electronic I...

Page 8: ...ts individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa If gas piping from the so...

Page 9: ...easily disconnected for burner or fan servicing See gas specification for pressure details and ratings NOTE If flex connector is used it must be kept inside of the appliance Fig 8 FP598 Fig 8 Typical...

Page 10: ...e of the EB1 while being careful to position excess wire completely within the EB1 Attach the coverplate to the fireplace Fig 11 Fig 11 Junction box EB 1 hook up FP580 Outside Electrical Box Front Of...

Page 11: ...tem using a maximum of two 45 degree elbows B Acceptable venting configuration Unacceptable venting configuration FP567a Fig 14 Venting configurations when installing 36GSKBB 40 38 36 34 32 30 28 26 2...

Page 12: ...deposit a slight film on the glass It is therefore recommended that the glass be cleaned two or three times with a non ammonia household cleaner and warm water we recommend gas fireplace glass cleane...

Page 13: ...ss this moisture disappears in a few minutes of burning Flame Adjustment For units equipped with Hi Lo valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the ce...

Page 14: ...these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF...

Page 15: ...the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempting repair may result in a fire or explos...

Page 16: ...nections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV...

Page 17: ...Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas...

Page 18: ...ost of these components may require only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a qualified technician In order to proper...

Page 19: ...3867 20003909 2 Lava Rock Package 20000376 20000376 3 Bag of Embers 7060109 7060109 4 Burner Housing w Tile 20003791 20003953 5 Ceramic Tile single 57803 57803 6a Burner Orifice Natural Manifold Orifi...

Page 20: ...ot Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 A...

Page 21: ...speed adjustment of the fan Electrical Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic ignition models Glass Doors Bi fold an...

Page 22: ...c Fireplaces NVB Series B Vent 7412950 Shrouds Decorative shrouds are available to enhance the appearance of the termination cap Square Shroud SSKDKU Pagoda Shroud PSKDKU Bishop Shroud BSKDKU TT Shrou...

Page 23: ...f upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provis...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic Products...