BFC36 Balance Flue Heat-Circulating Fireplace

7412647

LIMITED WARRANTY & 30 YEAR PROTECTION PLAN

For MAJESTIC FIREPLACES

®

 PRE-ENGINEERED Fireplace Systems

CFM Corporation warrants its MAJESTIC FIREPLACES® Pre-
Engineered  Fireplace  (“Fireplace”)  and  the  CFM  Corporation 
supplied firegrate, glass doors, outside air system, fan motor, 
and liners to be free from defects in material or workmanship, 
as follows:

A. Fireplace and Chimney Components:

 (exclusive of CFM 

Corporation-supplied firegrate, glass doors, outside air system, 
fan motor, and liners all of which are covered by separate war-
ranties under paragraphs B through D below): At its option for a 
period of thirty (30) years from the date the Fireplace is installed, 
CFM Corporation will;
1.  For a period of five (5) years from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter,  through  the  10th  year  after  the  date  the  Fire-

place is installed, if replacement parts are available, CFM 
Corporation will provide a replacement for any defective part 
without charge for the part itself.  The consumer must pay 
for everything else other than the part.

3.  Thereafter, through the 30th year after the date the Fireplace 

is installed, if replacement parts are available,CFM Corpora-
tion will provide a replacement for any defective part at a cost 
to the consumer of CFM Corporation then current list price, 
FOB CFM Corporation factory.

B. Firegrate, Glass Doors, Outside Air System:

For a period of 90 days from the date the Fireplace is installed 
CFM Corporation, at its option, will provide a replacement for 
any defective part, without charge for the part itself, FOB CFM 
Corporation factory, (The consumer must pay for everything else 
other than the part,).

C. Fan Motor:

1.  For a period of one (1) year from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter, through the 30th year after the date the Fireplace 

is  installed  CFM  Corporation,  at  its  option,  if  replacement 
parts are available, will provide a replacement for any defec-
tive part at a cost to the consumer of CFM Corporation then 
current list price, FOB CFM Corporation factory.

D. Liners (Refractory or Metal):

1.  For a period of two (2) years from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter, through the 30th year after the date the Fireplace 

is installed CFM Corporation, if replacement parts are avail-
able, will provide a replacement for any defective part at a 
cost to the consumer of CFM Corporation then current list 
price, FOB CFM Corporation factory.

This warranty is subject to the following conditions and limita-
tions:
1.  This warranty is extended only to a Fireplace installed in the 

continental United States, the state of Alaska and Canada; 
only if and so long as the Fireplace is installed or serviced by a 
qualified installer, preferably NFI or WETT (Canada) certified, 
and according to the installation instructions furnished with 

the Fireplace, and operated at all times under normal condi-
tions, use and service according to the operative instructions 
furnished with the Fireplace, and only if and so long as the 
Fireplace is not removed from its original installation.

2.  This warranty is non-transferrable, and is made to the original 

owner,  provided  that  the  purchase  was  made  through  an 
authorized supplier of the Company.

3.  The sole and exclusive remedies for breach of any warranties 

hereunder shall be for the repair, replacement or provision 
of a replacement part at CFM Corporation then current list 
price, FOB CFM Corporation  factory, for any defective part 
as specified in paragraphs A through D.

4.  CFM Corporation shall not be liable for damage from any 

smoking  of  a  MAJESTIC  FIREPLACES  Pre-Engineered 
Fireplace  System  related  to  environmental  geographic 
conditions (such as, for example, nearby structures or roof 
peaks, trees, hills, or mountains), inadequate ventilation, or 
negative air pressure in the place where the Fireplace system 
is installed, related to any mechanical system (such as, for 
example,  furnaces,  fans,  air  conditioners,  clothes  dryers, 
etc.)

5.  Except  as  otherwise  expressly  specified  in  paragraphs A 

through D, NONE OF THESE WARRANTIES COVER, AND  
CFM CORPORATION SHALL NOT BE RESPONSIBLE FOR, 
ANY CONSTRUCTION, INSTALLATION, LABOR, TRANS-
PORTATION OR OTHER COSTS OR EXPENSES ARISING 
FROM A DEFECTIVE PART, ITS REPAIR OR REPLACE-
MENT OR OTHERWISE, NOR SHALL CFM CORPORATION 
IN ANY EVENT BE RESPONSIBLE FOR ANY INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT 
TO THE EXTENT REQUIRED BY LAW.  Some states do not 
allow the exclusion or limitation of incidental or consequential 
damages,  so  this  exclusion  or  limitation  may  not  apply  to 
you.

NO  IMPLIED  WARRANTIES,  INCLUDING  THE  IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE, SHALL REMAIN IN EFFECT AF-
TER THE EXPIRATION OF THE WARRANTIES SET FORTH 
IN PARAGRAPHS A THROUGH D.  Some states do not allow 
limitations on how long an implied warranty lasts, so this limita-
tion may not apply to you.
In  order  to  obtain  performance  of  any  of  the  above  warranty 
obligations write to CFM Corporation at this address:
   

CFM Corporation

   

410 Admiral Blvd.

   

Mississauga, Ontario, Canada L5T 2N6

   

Attention: Director of Warranty Services

Since local building requirements may vary greatly throughout 
the country, users of CFM Corporation products should deter-
mine in advance whether there are any building code restrictions 
on the use of a specific product. CFM CORPORATION MAKES 
NO REPRESENTATION OR WARRANTY REGARDING, AND 
SHALL NOT BE RESPONSIBLE FOR, ANY BUILDING CODE 
COMPLIANCE.
The foregoing warranties give you specific legal rights and you 
may also have other rights which vary from state to state.

Summary of Contents for Monarch BFC36

Page 1: ...Closed Combustion Heat Circulating Fireplace Model BFC36 For use in the U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 7412647 4 07 Rev 13 Hom...

Page 2: ...d or approved by CFM Corpo ration in combination or assembly with a CFM Corporation replace system notwithstand ing any independent testing laboratory or other third party approval of such component p...

Page 3: ...ge 647 BFC36 specs 8 18 00 djt 13 Dia 343mm Rough Opening Width 43 Rough Opening Height Rough Opening Depth Gas Line Access 51 1297mm 51 1297mm 1 8 3 4 m m 197mm 23 584mm 610mm 624mm 39 997mm 246mm 35...

Page 4: ...tstop Standoff Surround Trim Ledge Standoff Glass Door Romex Pigtail Gas Line Access Knock out Each Side Air Inlet Basket Grate Bottom Grille Metal Safety Strip s Shown not inplace 1 2 or 3 pieces Nai...

Page 5: ...et of angled run of chimney Chimney supports are required for every 30 feet and 60 feet of vertical chimney height above the hearth Determine the offset distance of your chimney arrangement from the c...

Page 6: ...2 total 45 elbows in Canada per replace may be used 6 A guy wire stabilizer is required for chimneys extend ing more than 6 1 8m above a roof line The Ten Foot Rule Major U S building codes specify a...

Page 7: ...w the chimney system should be run contact your Ver mont Castings Majestic Products dealer for assistance Installation Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate it...

Page 8: ...ts must be tight NOTE Check local building codes to determine if junction box is required at the romex pigtail house wire connection Also check junction box and speed control SCVS installation instruc...

Page 9: ...ut Check to see where existing ceiling joists and other possible obstructions are located i e wiring plumbing etc If necessary re position chimney and or replace to avoid obstructions Cutting the Hole...

Page 10: ...in front of the replace This Z shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1 38mm wide and equal in length to the metals strips provided with...

Page 11: ...ness up to 8 203mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203mm adjustments must be made in framing to assure that minimum air spaces to chimney are m...

Page 12: ...y adjacent combustible surfaces Combustible surfaces include burnable materials such as ceiling members joists ooring combustible insulation and roof structures WARNING Do not pack required air spaces...

Page 13: ...ns are not a substitute for local building codes You must check your local building codes to determine speci c requirements for your city or state NOTE Other building materials may be required in addi...

Page 14: ...antel clearances 12 from top of grille opening 6 from top of grille opening Face Plate FP531b mantel clearances 9 03 djt 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Fig 19 Mantel clearance Combustibl...

Page 15: ...protect hearth extension material Fig 21 Secure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hear...

Page 16: ...mine the thickness required for any new mate rial NEW K of new material per inch thickness required X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 45...

Page 17: ...tub to the right and up Close the door and turn the handle stub to the left and down to secure door Fig 26 Left Handle is Stationary Turn Counter clockwise to Open FP1596 Fig 26 Turn right door handle...

Page 18: ...d 2 complying with the Standard for Decorative Gas Appliances for Installa tion in Vented Fireplaces ANSI Z21 60 or CSA draft requirements for Gas Fired Log Lighters for Woodburn ing Fireplaces Draft...

Page 19: ...20008275 5 Right Door Assembly Complete 20008276 6 Rear Firebrick 2353145 7 Side Firebrick two per replace 2353146 8 Hearth Firebrick 2353140 9 Nailing Flange four per replace 2422198 10 Fiberglas Rop...

Page 20: ...Balance Flue Heat Circulating Fireplace 7412647 BFC Balanced Flue Fireplace continued 25 Stud 3 8 16 x 1 20009776 26 Nut Hex Jam 3 8 16 Toplk 1203290 27 Black Fall Away Handle 20006382 Ref Descriptio...

Page 21: ...such must be oper ated only with CFM Corporation approved components If you use an unapproved component to make any modi cations you may create a possible re hazard and will void the CFM Corporation...

Page 22: ...ng is not included TT200C Adapter Kit TT8CB is required Chase Top Housing Used with chase terminations to prevent rain entry FL88 8 ue Contemporary Flashing 8 6 12 with 8 ue Required for Contemporary...

Page 23: ...place installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a quali ed installer preferably NFI or WETT Canada cert...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: