background image

22

GBR Series B-Vent Gas Fireplace

7412955

* Must order Honeywell Valve 30000030

GBR36

 

(continued)

 

Ref.  Description 

GBR36

 

3d.  Burner Orifice - LP (Model #F35B0B) 

20005251 

  4a.  Pilot Orifice - Natural (Up to and including F34A0B) 

54273

  4b.  Pilot Orifice - LP (Up to and including F34B0B) 

54272

  4c.  Pilot Orifice - Natural (Model #F35A0B) 

10002268

  4d.  Pilot Orifice - LP (Model #F35B0B) 

10002269

  5a.  Pilot Assembly Nova - Natural 

52445

  5b.  Pilot Assembly Nova - LP 

52446

 

6.  Piezo Ignitor 

52464

 

7.  Wire Assembly 

7522432

 

8.  Electrode Ignitor Nova 

52465

 

9.  Pilot Tubing 

7549346

  10.  Thermocouple 24” - Lead 

7531137

  11.  Thermogenerator 

7533113

  12a.  Valve Nova - Natural 

7529141

  12b.  Valve Nova - LP 

7529142

  13.  Ceramic Panel - Back 

2124102

  14.  Ceramic Panel - Left/Right Side 

2124103

  16.  Glass Panel (1 of 4) 

7540637

  17.  Door Track 

3061104

  18.  Remote Switch Kit 

53875

  19.  Lava Rock Package 

20000376

  20.  Bag of Embers 

7060109

  21.  Valve Cover 

3078116

  22a.  Electronic Valve - Natural 

57884

  22b.  Electronic Valve - LP 

57883

  23a.  Electronic Pilot Assembly - Natural 4 Way 

54219

  23b.  Electronic Pilot Assembly - LP 4 Way 

54221

  24.  Transformer 

7522409

  25.  Ignition Module / Honeywell 

20000005

  26.  Sensing Electrode 

57885

  27a.  Valve Honeywell - Natural 

20000541

  27b.  Valve Honeywell - LP 

30000030

  28.  Piezo Ignitor 

20000062

  29.  Thermodisk 

20001558

  30.  O.S.A. Assy. 

20003076    

  31.  Conversion Kit - Natural  

20002051 

 

 

 

 

Serial #'s F32B0B 99359900 and Above) 

20003037

  32.  Conversion Kit - LP (Serial #'s F32A0B99319875 through F33A0B99449956)* 

20002053 

 

 

 

 

For Serial #'s F33A0B99449957 

20003036

  33.  Conversion Kit - Natural Model #F35B0B 

20005244

  34.  Conversion Kit - LP Model #F35A0B 

20005243

  35.  Pilot Top Convertible 

10002266 

  36a.  Regulator Head (Nat.) 

10001006

  36b.  Regulator Head (LP) 

10001007

  37.  Screen Assembly 

3030117

  38.  Screen Rod Assembly 

3030126

  39.  Screen Assembly (2 per fireplace) 

7554338

  40.  Screen Pulls 

7554239

Summary of Contents for GBR36 Series

Page 1: ...YOUR SAFETY Installation and service must be per formed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of...

Page 2: ...bustibles 5 Mantels 5 Mantel Chart 5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Ga...

Page 3: ...any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal or wood panel extending the full...

Page 4: ...m 140mm 40 1016mm 36 914mm 3 76mm 1 6 m m 37 953mm 13mm 1 3 7 2 m m 502mm 533mm 40 1029mm 191mm 165mm 191mm 191mm Outside Air Electrical Access Gas Line Access WFP623 GBR36 2 11 98 Rough Opening Heigh...

Page 5: ...M L K J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta Black Surround Face Side of Combustion Chamber CFM170 CFM164 Hearth Extension A hearth extension in front of appliance is recommend ed...

Page 6: ...obstruct or modify the air inlet outlet grilles in any manner Finish the wall with the material of your choice Refer to Figures 2a and 2b for speci c clearances when install ing a combustible mantel o...

Page 7: ...nient to bring the gas line in from the right side as this allows fan installation or removal without disconnecting the gas line NOTE The gas line connection can be made with 3 8 copper tubing 1 2 rig...

Page 8: ...to a conveniently located wall receptacle box 2 Attach wire to switch and install switch into recep tacle box Attach cover plate to switch 3 Connect wiring to gas valve Refer to Figure 6 or 7 dependin...

Page 9: ...tion excess wire completely within the EB1 Attach the cov erplate to the replace Fig 8 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Front Of Unit Inside Front Of Unit FP580 F...

Page 10: ...run can be installed within the vent system using a maximum of two 45 degree elbows B FP567a Fig 11 Venting con gurations when installing 36GSKBB FP567 Fig 10 Venting con gurations Venting Runs 40 38...

Page 11: ...hold cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean gla...

Page 12: ...s valve standing pilot only FP390 L O H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Flame Characteristics It is important...

Page 13: ...smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace D...

Page 14: ...ll not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re or explosion D Do not use this appliance if any part has been un...

Page 15: ...eded All wiring connections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple need...

Page 16: ...ight All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Thermodisk Pilot Lights with Piezo Ig...

Page 17: ...n cable for signs of melting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check elect...

Page 18: ...ner tube 7 Reinstall burner tube and retaining bracket Burner ori ce and air shutter conversion complete FC102 Air shutter 7 21 99 djt Burner Tube Retaining Screw Air Shutter Air Shutter Gap FC102 Fig...

Page 19: ...the main burner ON check for leaks around the burner ori ce Be careful of the burner ame Tighten ori ce if necessary 5 With the main burner ON rotate the HI LO knob and verify proper burner operation...

Page 20: ...y a quali ed technician In order to properly clean the burner and pilot assem bly turn off the gas to the unit open the glass door if used remove logs exposing the burner and pilot assembly Clean all...

Page 21: ...the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice GBR36 Units F35A0B F34H0B Ref Description GBR36 1 Log Set Assembly 200...

Page 22: ...Kit 53875 19 Lava Rock Package 20000376 20 Bag of Embers 7060109 21 Valve Cover 3078116 22a Electronic Valve Natural 57884 22b Electronic Valve LP 57883 23a Electronic Pilot Assembly Natural 4 Way 542...

Page 23: ...appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Corporation 2695 Meadowvale Blvd Mississau...

Page 24: ...NOTE Not for use in Canada Remote Controls Optional remote control units are available to control different functions of the appliance Model Function s Controlled RC1 ON OFF RC2 ON OFF and Temperature...

Page 25: ...25 GBR Series B Vent Gas Fireplace 7412955...

Page 26: ...26 GBR Series B Vent Gas Fireplace 7412955...

Page 27: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions o...

Page 28: ...cy Ratings Model EnerGuide Ratings Fireplace Ef ciency GBR36RN 15 5 GBR36RP 15 5 GBR36EN 11 6 GBR36EP 11 6 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corp...

Reviews: