background image

3

4.  Converting LP to NG, remove bracket/gasket as-

sembly by unfastening the screw which secures the 
bracket to the burner tray base. Discard bracket and 
refasten the screw into the hole. (Fig. 9)

  Converting NG to LP, assemble the bracket/gas-

ket assembly to the burner tray assembly base by 
unfastening the screw on the tray to the right side of 
the orifice. Slide the bracket/gasket assembly over 
the fitting on the manifold toward the back with the 
gasket to the right. Secure the bracket/gasket as-
sembly using the screw removed earlier. (Fig. 9)

�����
����������
����

LP Bracket/Gas-

ket Assembly - in 

place for use with 

LP Gas; remove 

for use with Natu-

ral Gas

Screw

CO132

Fig. 9

  LP bracket/gasket assembly.

5.  Replace the orifices according to the table on Page 

4.

6.  Replace the mixing tube on the burner housing by 

removing the two (2) screws that secure the mixing 
tube to the burner housing assembly. Remove the 
old gasket behind the mixing tube. (Fig. 10) 

NOTE: 

The mixing tube for propane gas has only two 
bimetallic springs that are in the closed position 
at cold start. The mixing tube for natural gas has 
two spring/shutter collar assemblies that are in 
the closed position at cold start. Make sure the 
correct mixing tube is used for conversion.

7.  Use the new gasket supplied in the conversion kit 

and proper mixing tube and replace in reverse order.

8.  Reassemble the burner housing assembly, the 

burner tube assembly and the fettle in reverse orde

Pilot Orifice Conversion - R Models 

NOTE:

 It is not necessary to remove the pilot tube for 

conversion.
1.  Remove pilot hood by lifting up. (Fig. 11)
2.  Remove pilot orifice with Allen wrench. (Fig. 12)
3.  Install conversion pilot orifice.
4.  Re-install pilot hood and be sure to align with index 

tab. Installation is complete.

�����
�����������
���������

Burner Housing

Gasket

Mixing Tube

CO131

Fig. 10

  Replace mixing tube and gasket.

Natural

Propane

CO105a

DV360/580

Gas Conversion

Pilot

1/28/00   djt

Pilot Hood

Pilot 

Bracket

CO105a

Fig. 11

  Remove pilot hood.

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00   djt

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 12

  Remove pilot orifice.

Pilot Orifice Conversion - RF Models

NOTE:

 It is not necessary to remove the pilot tube for 

conversion.

1.  Loosen pilot hood turning counterclockwise using a 

7/16” wrench. (Fig. 13)

2.  Remove pilot orifice with needlenose pliers. (Fig. 14)
3.  Install conversion pilot orifice.
4.  Reinstall pilot hood. Be sure to align pilot hood with 

index marks.

5.  Turn the gas supply valve and gas valve on and test 

for leaks. Use a 50/50 solution of liquid soap and 
water to test for leaks at gas fittings and joints. Apply 
water/soap solution with brush only - 

do not over ap-

ply. 

NEVER test with an open flame.

6.  Follow procedure on rating plate to light the pilot. 

Check for leaks.

Summary of Contents for 20010751

Page 1: ...emove logs if previously installed Honeywell Valve 1 Remove cap from HI LO knob This can be accom plished by lifting the plastic cap off the screw Fig 2 2 Remove the screw from center of HI LO knob with small screwdriver turning counterclockwise Fig 2 20010843 3 08 Rev 4 CO100 Gas conversion HI LO knob 3 15 99 djt L O H I L O H I Cap Hi Lo Knob Lift Open Remove Center Screw CO100 Fig 2 Remove cent...

Page 2: ...MOTE O N PILOT OFF L E D Motor Top Cap Piezo Ignitor LED Local Remote Switch Pilotstat Knob Plug Antenna FP1037 Fig 5 Comfort control valve FP1037b comfort valve convert 3 6 01 djt LOCAL REMOTE O N PILOT OFF L E D Motor Top Cap Center Plunger Blue NG Red LP FP1037b Fig 6 Depress and turn center plunger Burner Orifice Conversion 1 Remove the screws that secure the fettle and the burner tube assembly...

Page 3: ... in the conversion kit and proper mixing tube and replace in reverse order 8 Reassemble the burner housing assembly the burner tube assembly and the fettle in reverse orde Pilot Orifice Conversion R Models NOTE It is not necessary to remove the pilot tube for conversion 1 Remove pilot hood by lifting up Fig 11 2 Remove pilot orifice with Allen wrench Fig 12 3 Install conversion pilot orifice 4 Re ins...

Page 4: ...g 14 Remove pilot orifice Conversion to Natural Gas Burner Orifice Input BTU hr Kit Model Front Part Rear Part Minimum Maximum 20010751 DV360RP RFP 53 20007347 43 30000512 18 500 30 000 0595 089 Conversion to LP Burner Orifice Input BTU hr Kit Model Front Part Rear Part Minimum Maximum 20010752 DV360RN RFN 64 20010935 54 20000130 17 000 30 000 20011025 DV360EN 036 055 Table 1 Injector Orifice Size Mat...