background image

Maipu Confidential & Proprietary Information

Page 1 of 24

SM4200-28FC(52FC)

SM4200-28FC(52FC)

SM4200-28FC(52FC)

SM4200-28FC(52FC) Install

Install

Install

Install Manual

Manual

Manual

Manual

V2.0

Maipu Communication Technology Co., Ltd

No. 16, Jiuxing Avenue
Hi-Tech Park
Chengdu, Sichuan Province
P. R. China
610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http://

www.maipu.com

Mail:

[email protected]

Summary of Contents for SM4200-28FC

Page 1: ...2FC SM4200 28FC 52FC Install Install Install Install Manual Manual Manual Manual V2 0 Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue Hi Tech Park Chengdu Sichuan Province P R China 610041...

Page 2: ...disclaims any implied warranties of merchantability or fitness for any specific purpose Further Maipu reserves the right to revise this document and to make changes from time to time in its content w...

Page 3: ...rial Editorial Language vocabulary readability clarity technical accuracy content Good Fair Average Poor Your Your Your Your suggestions suggestions suggestions suggestions to to to to improve improve...

Page 4: ...ption 10 SM42 2XFP SM42 2XGEF SM42 2GEF Extended Module Description 11 Device Device Device Device Installation Installation Installation Installation 14 14 14 14 Installation Notice 14 Installation E...

Page 5: ...28FC 12 optical ports 12 Combo two extended cards DC power supply SM4200 52FC 44 optical ports 4 Combo two extended cards DC power supply Product Introduction Overview The front panel of SM4200 28FC...

Page 6: ...ports 802 1d w s 802 1Q 802 1p 802 3ad 802 3x GVRP DHCP and SNTP multicast protocols such as IGMP DVMRP and PIM routing protocols such as RIPv1 2 OSPF and IPv6 including RIPng OSPFv3 BGP4 routing prot...

Page 7: ...ork network network network management management management management The switch supports SNMP out band and in band management CLI and WEB interfaces and RMON It adopts SMTP protocol to automaticall...

Page 8: ...one 48V DC power input interface and one 220V AC power input interface from left to right as shown in the following figure Figure 1 3 SM4200 28FC back panel The back panel of SM4200 52FC is the same a...

Page 9: ...Meaning Meaning Meaning Meaning Green On The port is linked Off The port is not linked Flash Data sending and receiving Table 1 3 Description of SFP port indicators Indicator Indicator Indicator Indic...

Page 10: ...card M1 is linked Green flashing Port 2 of the extended card M1 has data sending and receiving Off Port 2 of the extended card M1 is not linked Orange on Port 2 of extended card M1 is not linked but t...

Page 11: ...9 125um single mode fiber 120km SFP GT SFP GT module 1000Base T SFP interface card module RJ 45 interface SM42 2XFP SM42 2XGEF SM42 2GEF Extended Module Description The back panel of the switch provid...

Page 12: ...re 1 9 SM42 2GEF panel diagram The back panel diagram after the switch is installed with the extended module is as follows Figure 1 10 Back panel after SM4200 28FC SM4200 52FC is installed with the ex...

Page 13: ...scription Specifications Specifications Specifications Specifications XFP XFP SR transceiver 10GBase SR XFP multi mode fiber transceiver 850nm 62 5 m MMF 32m 50 m 500MHz km MMF 85m 50 m 2000MHz km MMF...

Page 14: ...for good air circulation The switch should work in the power AC 90V 264VAC 50Hz DC 40 60VDC Ground the switch properly to avoid ESD damage and physical injury Avoid direct sunlight on the switch Keep...

Page 15: ...loose Meanwhile in dry environment static electricity appears easily which harms the circuits on the switch If the temperature is too high the reliability of the switch reduces greatly The long time...

Page 16: ...erature and humidity Wear an ESD wrist strap and antistatic uniform when in contact with circuit boards Anti Interference All sources of interference whether from the device or outside environment aff...

Page 17: ...tallation it is required to use the brackets and screws provided in the accessory kit and proper tools to ensure stability and reliability Users should always wear antistatic uniforms and ESD wrist st...

Page 18: ...ecurity Place the emergency power switch in the working site so that the power can be cut off immediately if any accident occurs Caution Caution Caution Caution The potential dangers include electric...

Page 19: ...of the switch with screws provided in the accessory kit 2 Put the bracket mounted switch onto a standard 19 rack Fasten it at a proper location with the screws provided leaving enough space around the...

Page 20: ...it optical interface on the switch provides multiple SFP Gigabit fiber ports The steps for installing SFP Gigabit fiber transceiver Step Step Step Step 1 1 1 1 Put on ESD wrist strap or antistatic glo...

Page 21: ...swappable Install SM42 2XGEF Extended Module The switch provides 10G slot The steps for installing SM42 2XGEF module and the SFP 10G fiber transceiver on the module are as follows 1 Put on ESD wrist s...

Page 22: ...Insert one end of the Ethernet cable to the RJ 45 Ethernet interface of the switch electrical interface Step Step Step Step 2 2 2 2 Insert other end of the Ethernet cable to the RJ 45 Ethernet port of...

Page 23: ...the power cable as follows 1 Insert one end of the power cable provided in the accessory kit into the AC power slot on the back panel of the switch and the other end to power socket with overload and...

Page 24: ...witch is on 3 After the switch is powered on it automatically executes self check and startups Caution Caution Caution Caution The input voltage should be within the required range or switch can be da...