background image

WAN

switch

HARDWARE

guide

WAN

switch

/W2358D

SL

LINKS

1

2

3

4

5

6

7

8

analyzer A
analyzer B

daisy A
daisy B

WAN

switch

/W2358D

SL

DATACOMsystems

Empowering Network Professionals

DATACOM

SYSTEMS INC

Summary of Contents for WANswitch W2358DSL

Page 1: ...WANswitch HARDWAREguide WANswitch W2358DSL LINKS 1 2 3 4 5 6 7 8 analyzer A analyzer B daisy A daisy B WANswitch W2358DSL DATACOMsystems Empowering Network Professionals DATACOM SYSTEMS INC ...

Page 2: ......

Page 3: ...i March 2002 W2358DSL Part Number 541 0052 C 01 WANswitch HARDWAREguide ...

Page 4: ...ii ...

Page 5: ... you do not agree to all of the terms set forth therein do not install the software If applicable you may return the product to the place of purchase for a full refund Proprietary Notice This document contains proprietary information about the WANswitch and is not to be disclosed or used except as autho rized by written contract with Datacom Systems Inc Trademark Attribution DS3 ACTIVEtap DS3switc...

Page 6: ...ic 4 Specs General Electrical Environmental Mechanical A1 Panel Description Front Panel B1 Rear Panel B3 Daisy Chain Daisy Chain Addressing Connection Instructions C1 Hardware Installation LM 2000 NIC C3 Hardware Installation WANic C5 Troubleshooting General No Power D1 Control Function D3 Access Function D5 Warranty Warranty Limitation On Liability E1 iv TABLE OF C CO ON NT TE EN NT TS S ...

Page 7: ...RDWAREguide is organized Section Appendix Contents Preface HARDWAREguide Purpose and Scope Introduction Product Overview Hardware Installation of Switch Specifications Switch Information Panel Description Front Rear Details Daisy Chain Multiple Switches Troubleshooting Solving Common Problems Warranty Our Guarantee to You Audience This HARDWAREguide is written for the person who must install and c...

Page 8: ...Eastern time weekdays Customer Service is avail able via telephone facsimile and Internet E mail Outside of support hours please leave a voice message and our Customer Service Staff will return your call as soon as possible Mail Datacom Systems Inc Customer Service 9 Adler Drive East Syracuse NY 13057 1290 Tel 315 463 9541 FAX 315 463 9557 E mail support datacomsystems com World Wide Web You can o...

Page 9: ...may have Like many network managers you have an urgent need to provide easy connectivity between an Analyzer and an array of attached Wide Area Networks The Datacom WANswitch is capable of providing connectivity for V 35 RS232 RS422 RS423 RS530 X 21 V 10 and V 11 Wide Area Networks The WANswitch is capable of moving Wide Area Network protocol analyzers transparently from one net work link to anoth...

Page 10: ...he DRL341 3 3 Control Y cable DB9 Male lead labeled A to the COM 1 port of one of the DSS Analyzers NOTE For single DSS Analyzer installations the DB9 Male lead labeled B has been factory tie wrapped into a 2 inch coil approximately 8 inches from the common connector so it can be easily stored above below or hang innocuously behind the DSI switch To install two Analyzers the DB9 Male lead labeled ...

Page 11: ...inks Common B Daisy B X length in feet standard cable X 3 feet Network Associates DSS Analyzer Sniffer Technologies DSS Analyzer Network Associates DSS Analyzer Sniffer Technologies DSS Analyzer DRL341 3 3 Control Y cable DRL312 3 Common Cables 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B Network Associates DSS Analyzer Sniffer Technologies DSS Analyzer Network Associ...

Page 12: ...60 Male lead to the MONITOR port of the DSS Analyzer Step 2 Connect the DRL 459 3 3 Common Cable DB15 Female lead labeled A to the Common A port of the WANswitch Step 3 Connect the DRL 459 3 3 Common Cable DB15 Female lead labeled B to the Common B port of the WANswitch Step 3 Connect the DRL341 3 3 Control Y cable DB9 Male lead labeled A to the COM 1 port of the DSS Analyzer NOTE For single DSS A...

Page 13: ... 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B Network Associates DSS Analyzer Sniffer Technologies DSS Analyzer DRL341 3 3 Control Y cable DRL459 3 3 Common Cable CSU DSU Bridge Router DRL311 2 4 Y cable Bridge Router CSU DSU DRL311 2 4 Y cable A B ...

Page 14: ...equirements Table A1 shows the WANswitch capacity network type network connectivity product weight and shipping weight Electrical Nominal Power Requirements The WANswitch has been provided with an external power supply requiring 100 240 Volts AC at 50 60 Hertz This supply is provided as a stan dard no charge accessory The DC voltage and current out put ratings are 5 Volts DC at 4 0 Amperes 12 Volt...

Page 15: ...A2 Table A1 WANswitch Specifications WANswitch SWITCH CAPACITY NETWORK TYPE NETWORK CONNECTIVITY PRODUCT WEIGHT SHIPPING WEIGHT W2358DSL 2x8 WAN DB15 13 20 ...

Page 16: ...below a number legend indicates a completed connection has been made from that WAN link to the Common A port A red light below a number legend indicates a completed connection has been made from that WAN link to the Common B port Daisy A A green light next to the Daisy A legend indicates that the Daisy A port is connected to the next WANswitch Common A port Daisy B A red light next to the Daisy B ...

Page 17: ...B2 Figure B1 W2358DSL Front Panel LINKS 1 2 3 4 5 6 7 8 analyzer A analyzer B daisy A daisy B WANswitch W2358DSL DATACOMsystems ...

Page 18: ... the WANswitch is daisy chained Common B This connector port is a shielded DB15 Male and is cabled to the MONITOR port of a second DSS or previous switch Daisy B port if daisy chained The WANswitch connects the selected network link port 1 8 to Common B port Control This connector port is a shielded DB9 Female and is cabled to the COM 1 port of both DSS s or to the previous switch Link port if dai...

Page 19: ...B4 Figure B2 W2358DSL Rear Panel 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B ...

Page 20: ...t a time with the ATTACHit program as described in the DATACOMswitch SOFTWAREguide Connection Instructions The typical daisy chain addressing installation described herein will be for a WANswitch Step 1 Connect the COM1 port of the computer platform to the Control port of the WANswitch using a DRL341 3 3 cable as shown Figure C1 Step 2 Connect the Power Supply 5 pin DIN Male connector into the Pow...

Page 21: ...C2 Figure C1 Connectivity for Daisy Chain Addressing DRL341 3 3 Control Y cable 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B Server or PC A B ...

Page 22: ...ep 2 Connect the DRL341 3 3 Control Y cable DB9 Male lead labeled A to the COM 1 port of one of the DSS Analyzers NOTE For single DSS Analyzer or daisy chain installations the DB9 Male lead labeled B has been factory tie wrapped into a 2 inch coil approximately 8 inches from the common connector so it can be easily stored above below or hang innocuously behind the DSI switch To install two Analyze...

Page 23: ... A Daisy A Link Control Power Links Common B Daisy B 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B DRL312 3 Common Cables DRL312 3 Common Cables DRL312 3 Common Cables Address 0 Address 1 Address 2 Address 3 Up to 32 Segments B A DRL341 3 3 Control Y cable DRL341 3 3 Control Y cable DRL341 3 3 C...

Page 24: ...ts connected to the Common A and Common B ports respectively of the next WANswitch using a DRL312 3 cable Step 5 Connect the DRL341 3 3 Control Y cable DB9 Male lead labeled A to the COM 1 port of one of the DSS Analyzers NOTE For single DSS Analyzer or daisy chain installations the DB9 Male lead labeled B has been factory tie wrapped into a 2 inch coil approximately 8 inches from the common conne...

Page 25: ...ontrol Power Links Common B Daisy B 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B DRL312 3 Common Cables DRL312 3 Common Cables DRL312 3 Common Cables Address 0 Address 1 Address 2 Address 3 Up to 32 Segments DRL341 3 3 Control Y cable DRL341 3 3 Control Y cable DRL341 3 3 Control Y cable B A B ...

Page 26: ...vice D1 PROBLEM TROUBLESHOOTING SUGGESTIONS Please check the obvious Ensure that the Power Supply 5 pin DIN Male connector is inserted into position in the POWER port Check that the power cord is properly attached Verify that the external power source wall receptacle has power available Try plug ging another device into the outlet to see if it works If you have a known good power supply or power c...

Page 27: ...D2 ...

Page 28: ...gies SniffMaster Console software If a communications time out has occurred confirm that the proper Control Cable is in use A DRL341 3 3 Control Y cable must be used because the Control port is a modified RS232 that will work only with the Datacom supplied cables If the proper cable has been used sub stitute a known good DRL341 3 3 Control Y cable The DSS Analyzer from which you are trying to cont...

Page 29: ...D4 ...

Page 30: ...he cable not the switch Disconnect a patch cable from a switch port that is functioning properly and reconnect it to the suspect port If the suspect port still fails the problem is in the switch Contact Datacom Systems Inc Customer Service If the problem occurs consistently on all ports of the switch and the cables have been verified and checked try connecting the hub or MUX directly to the DSS Se...

Page 31: ...D6 ...

Page 32: ... NUMBER FROM DATACOM CUSTOMER SERVICE AT 315 463 9541 ITEMS WITHOUT AN RMA WILL BE REFUSED OR RETURNED FREIGHT COLLECT DSI shall have no responsibility for any deficiency resulting from accidents misuse modifications power disturbances e g lighten ing ESD use of a power supply not specified by DSI etc or var ious other forms of disaster e g earthquakes floods etc If returned equipment is found to ...

Page 33: ...E2 ...

Page 34: ...IVITY FS4MSL 4 100FX OC3 OC12 Gigabit Dual SC FS4SSL 4 OC3 OC12 Gigabit Dual SC FS8MSL 8 100FX OC3 OC12 Gigabit Dual SC FS8SSL 8 OC3 OC12 Gigabit Dual SC INSERTswitch MODEL PORTS TOPOLOGY CONNECTIVITY RT3216FDSL 1x16 10 100 Full Duplex RJ45 LANswitch MODEL PORTS TOPOLOGY CONNECTIVITY MX16100E TSL 2x16 10 100BaseT or RJ45 4 16 Token Ring MULTINETswitch MODEL PORTS TOPOLOGY CONNECTIVITY D28100BTSL 1...

Page 35: ......

Page 36: ...Datacom Systems Inc 9 Adler Drive East Syracuse New York 13057 TEL 315 463 9541 FAX 315 463 9557 http www datacomsystems com Empowering Network Professionals DATACOM SYSTEMS INC ...