S3100 Install Manual (For S3100-9/18/26TC (TP)) V5.0
Figure 2-1 Fasten the brackets to the switch
2.
Put the bracket-mounted switch smoothly into a standard 19’’ rack.
Fasten the S3100 switch to the
rack with the screws provided. Leave
enough
space
around the switch for good air circulation.
Figure 2-2 Fasten the Switch to the
Rack
Caution
The brackets are used to fix the switch on the rack. They can’t serve as a
bearing. Please place a rack shelf under the switch. Do not place anything
on top of the switch. Do not block the blowholes on the switch to ensure
the proper operation of the switch.
Connecting Console
MyPower S3100 series switch
provide a RJ45 serial console port.
Figure 2-3 Connecting Console to S3100
The connection procedure is listed below: