Item

Item

Item

Item

Description

Description

Description

Description

Console

RJ45, EIA/TIA-232

100M Ethernet interface

100M Ethernet interface(RJ45);support POE

GE SFP

1000M (SFP)

FLASH

8Mbytes

SDRAM

64Mbytes

Size (W×D×H)

250×180×44mm

Weight

1.74Kg

Input voltage

AC:100-240V, 50/60Hz

Temperature

0-50

Humidity

5-95%

Rated power supply

20W (3.3V Output power)

150W (-48V PSE output power)

Max power consumption

10W

1.3

1.3

1.3

1.3

Service

Service

Service

Service F

F

F

Features

eatures

eatures

eatures

Table1-3

Table1-3

Table1-3

Table1-3 Service

Service

Service

Service features

features

features

features of

of

of

of SM

SM

SM

SM 3100-9TP-AC

3100-9TP-AC

3100-9TP-AC

3100-9TP-AC

Service

Service

Service

Service

Realization

Realization

Realization

Realization

VLAN

4K VLAN entries.

Port-based and MAC-based VLAN

Private VLAN

Port-isolation in a VLAN

Port QinQ and selective QinQ

1:1 and N:1 VLAN switching

MAC

8K MAC address

Aging time and add/remove static MAC

MAC Black Hole

Port MAC Limit

Disable MAC address learning on port or

channel-group

Multicast

1K L2 multicast groups

IGMPv1/v2/v3 Snooping

IGMP Filter/Fast leave/cross-VLAN

duplication

MLDv2/MLDv2 Snooping

Summary of Contents for SM 3100-9TP-AC

Page 1: ...Manual 2011 Maipu Communication Technology Co Ltd All Rights Reserved 1 SM SM SM SM 3100 9TP AC 3100 9TP AC 3100 9TP AC 3100 9TP AC Installation Installation Installation Installation Manual Manual M...

Page 2: ...to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose Further Maipu reserves the right to revise this document and to make...

Page 3: ...2 3 2 3 2 3 2 3 Check Check Check Check Device Device Device Device and and and and Accessories Accessories Accessories Accessories 10 10 10 10 2 4 2 4 2 4 2 4 Tools Tools Tools Tools for for for for...

Page 4: ...re Failure Failure 16 16 16 16 5 2 5 2 5 2 5 2 Configuration Configuration Configuration Configuration System System System System Failure Failure Failure Failure 16 16 16 16 5 3 5 3 5 3 5 3 Troublesh...

Page 5: ...r switching switching switching switching SM 3100 9TP AC series switches fulfills the enterprise customers requirement of designing and implementing unified highly resilient networks 2 2 2 2 Comprehen...

Page 6: ...maintenance maintenance maintenance and and and and management management management management Supports a variety of maintenance and management as SNMP SSH TACACS cluster management RMON and CLI whic...

Page 7: ...m Flicker System operation normal Always on off System operation abnormal Combo indicator 9X On Normal connection Off Disconnection Flicker Sending receiving data LINK indicator Off Disconnection On N...

Page 8: ...Service Service F F F Features eatures eatures eatures Table1 3 Table1 3 Table1 3 Table1 3 Service Service Service Service features features features features of of of of SM SM SM SM 3100 9TP AC 3100...

Page 9: ...ng available on CPU queues Programmable priority to CoS queue mapping Provide two levels of drop precedence per queue SP WRR DRR Upgrading Support Xmodem FTP and TFTP protocol to realize upgrading Man...

Page 10: ...Installation Manual 2011 Maipu Communication Technology Co Ltd All Rights Reserved 6 Maintenance Supports debug information output Support PING Supports system log...

Page 11: ...of of the the the the room room room room and and and and the the the the switch switch switch switch Switch Switch Switch Switch can can can can work work work work normally normally normally normall...

Page 12: ...emperature temperature and and and and humidity humidity humidity humidity when when when when there there there there is is is is no no no no air conditional air conditional air conditional air condi...

Page 13: ...gs AC AC AC AC power power power power supply supply supply supply uses uses uses uses TN TN TN TN system system system system and and and and the the the the plug plug plug plug adopts adopts adopts...

Page 14: ...uired Installation environment you can open the box However before the formal installation you need to carefully check the packing list of the device within the box of equipment and accessories are co...

Page 15: ...le reticle Device needed Configuration Configuration Configuration Configuration terminal terminal terminal terminal can can can can be be be be PC PC PC PC 3 1 2 3 1 2 3 1 2 3 1 2 Check Check Check C...

Page 16: ...cooling cooling there there there there should should should should be be be be 1U 1U 1U 1U distance distance distance distance between between between between two two two two installed installed inst...

Page 17: ...ightning voltage ground can provide protection Use a thick wire and connect the points with the earth grounding resistance is less than 4 ohms If the switch is installed in the cabinet the cabinet als...

Page 18: ...RJ45 RJ45 RJ45 Descripition Descripition Descripition Descripition Length Length Length Length 1 TX0 1 1 twisted pair 2m 2 TX0 2 3 RX0 3 2 twisted pair 6 RX0 6 4 48V 4 3 twisted pair 5 48V 5 7 0V 7 4...

Page 19: ...s crimped RJ 45 connector which is inserted to Console interface the other end is a connector with DB 9 holes The Console cable is as the following picture The picture of Console cable Table 5 3 Conne...

Page 20: ...C Fast Ethernet Switch is on if the system works normally the booting information will be displayed in configuration terminal if there is failure in configuration system it will display nothing or ill...

Page 21: ...nication Technology Co Ltd All Rights Reserved 17 configuration of terminal such as hyper terminal baud rate is 9600 data bit is 8 and parity check is none stop bit is 1 flow control is none and choos...

Reviews: