background image

Installation Manual

©

2011

Maipu Communication Technology Co., Ltd,

All Rights Reserved

16

Chapter

Chapter

Chapter

Chapter 5

5

5

5

Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting

5.1

5.1

5.1

5.1 Power

Power

Power

Power S

S

S

System

ystem

ystem

ystem F

F

F

Failure

ailure

ailure

ailure

SM 3100-9TP-AC Fast Ethernet Switch can check the power system failure according to

the power indicator on the front board: when the power system works normally, the power

indicator keeps on; if it is off, please examine as following:

The

The

The

The correct

correct

correct

correct connection

connection

connection

connection of

of

of

of power

power

power

power wire.

wire.

wire.

wire.

The

The

The

The matching

matching

matching

matching of

of

of

of power

power

power

power supply

supply

supply

supply of

of

of

of switch

switch

switch

switch and

and

and

and power

power

power

power required.

required.

required.

required.

5.2

5.2

5.2

5.2 Configuration

Configuration

Configuration

Configuration S

S

S

System

ystem

ystem

ystem F

F

F

Failure

ailure

ailure

ailure

After The power of

SM 3100-9TP-AC Fast Ethernet Switch is on, if the system works

normally, the booting information will be displayed in configuration terminal; if there is

failure in configuration system, it will display nothing or illegible characters.

5.3

5.3

5.3

5.3 Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting on

on

on

on N

N

N

No

o

o

o D

D

D

Displaying

isplaying

isplaying

isplaying

After the power is on, if the configuration terminal displays nothing, please examine the

device as following:

The

The

The

The power

power

power

power works

works

works

works normally.

normally.

normally.

normally.

The

The

The

The correct

correct

correct

correct connection

connection

connection

connection of

of

of

of Console

Console

Console

Console cable

cable

cable

cable

If there is no problem in above examination, maybe there is something wrong with the

parameter configuration of the terminal (such as hyper terminal) or the configuration

cable.

5.4

5.4

5.4

5.4 Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting on

on

on

on D

D

D

Displaying

isplaying

isplaying

isplaying IIIIllegible

llegible

llegible

llegible C

C

C

Characters

haracters

haracters

haracters

If illegible characters are displayed, parameter configuration of terminal (such as hyper

terminal) is incorrect. Please affirm parameter

Summary of Contents for SM 3100-9TP-AC

Page 1: ...Manual 2011 Maipu Communication Technology Co Ltd All Rights Reserved 1 SM SM SM SM 3100 9TP AC 3100 9TP AC 3100 9TP AC 3100 9TP AC Installation Installation Installation Installation Manual Manual M...

Page 2: ...to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose Further Maipu reserves the right to revise this document and to make...

Page 3: ...2 3 2 3 2 3 2 3 Check Check Check Check Device Device Device Device and and and and Accessories Accessories Accessories Accessories 10 10 10 10 2 4 2 4 2 4 2 4 Tools Tools Tools Tools for for for for...

Page 4: ...re Failure Failure 16 16 16 16 5 2 5 2 5 2 5 2 Configuration Configuration Configuration Configuration System System System System Failure Failure Failure Failure 16 16 16 16 5 3 5 3 5 3 5 3 Troublesh...

Page 5: ...r switching switching switching switching SM 3100 9TP AC series switches fulfills the enterprise customers requirement of designing and implementing unified highly resilient networks 2 2 2 2 Comprehen...

Page 6: ...maintenance maintenance maintenance and and and and management management management management Supports a variety of maintenance and management as SNMP SSH TACACS cluster management RMON and CLI whic...

Page 7: ...m Flicker System operation normal Always on off System operation abnormal Combo indicator 9X On Normal connection Off Disconnection Flicker Sending receiving data LINK indicator Off Disconnection On N...

Page 8: ...Service Service F F F Features eatures eatures eatures Table1 3 Table1 3 Table1 3 Table1 3 Service Service Service Service features features features features of of of of SM SM SM SM 3100 9TP AC 3100...

Page 9: ...ng available on CPU queues Programmable priority to CoS queue mapping Provide two levels of drop precedence per queue SP WRR DRR Upgrading Support Xmodem FTP and TFTP protocol to realize upgrading Man...

Page 10: ...Installation Manual 2011 Maipu Communication Technology Co Ltd All Rights Reserved 6 Maintenance Supports debug information output Support PING Supports system log...

Page 11: ...of of the the the the room room room room and and and and the the the the switch switch switch switch Switch Switch Switch Switch can can can can work work work work normally normally normally normall...

Page 12: ...emperature temperature and and and and humidity humidity humidity humidity when when when when there there there there is is is is no no no no air conditional air conditional air conditional air condi...

Page 13: ...gs AC AC AC AC power power power power supply supply supply supply uses uses uses uses TN TN TN TN system system system system and and and and the the the the plug plug plug plug adopts adopts adopts...

Page 14: ...uired Installation environment you can open the box However before the formal installation you need to carefully check the packing list of the device within the box of equipment and accessories are co...

Page 15: ...le reticle Device needed Configuration Configuration Configuration Configuration terminal terminal terminal terminal can can can can be be be be PC PC PC PC 3 1 2 3 1 2 3 1 2 3 1 2 Check Check Check C...

Page 16: ...cooling cooling there there there there should should should should be be be be 1U 1U 1U 1U distance distance distance distance between between between between two two two two installed installed inst...

Page 17: ...ightning voltage ground can provide protection Use a thick wire and connect the points with the earth grounding resistance is less than 4 ohms If the switch is installed in the cabinet the cabinet als...

Page 18: ...RJ45 RJ45 RJ45 Descripition Descripition Descripition Descripition Length Length Length Length 1 TX0 1 1 twisted pair 2m 2 TX0 2 3 RX0 3 2 twisted pair 6 RX0 6 4 48V 4 3 twisted pair 5 48V 5 7 0V 7 4...

Page 19: ...s crimped RJ 45 connector which is inserted to Console interface the other end is a connector with DB 9 holes The Console cable is as the following picture The picture of Console cable Table 5 3 Conne...

Page 20: ...C Fast Ethernet Switch is on if the system works normally the booting information will be displayed in configuration terminal if there is failure in configuration system it will display nothing or ill...

Page 21: ...nication Technology Co Ltd All Rights Reserved 17 configuration of terminal such as hyper terminal baud rate is 9600 data bit is 8 and parity check is none stop bit is 1 flow control is none and choos...

Reviews: