background image

 

 

MP2800 Series Router

Installation Manual 

Version 1.0

Maipu Communication Technology Co., Ltd 

No. 16, Jiuxing Avenue 
Hi-tech Park 
Chengdu, Sichuan Province 
People’s Republic of China - 610041 

Tel:

 (86) 28-85148850, 85148041 

Fax:

 (86) 28-85148948, 85148139 

URL:

 http:// 

www.maipu.com

Email:

 

[email protected]

 

Maipu Confidential & Proprietary Information 

      Page 

of 

55 

 

 

Summary of Contents for MP2801

Page 1: ...n Technology Co Ltd No 16 Jiuxing Avenue Hi tech Park Chengdu Sichuan Province People s Republic of China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 URL http www maipu com Email overseas maipu com Maipu Confidential Proprietary Information Page 1 of 55 ...

Page 2: ...ime in its content without being obligated to notify any person of such revisions or changes Maipu values and appreciates comments you may have concerning our products or this document Please address comments to Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue Hi tech Park Chengdu Sichuan Province People s Republic of China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 U...

Page 3: ...bility Contents index headings numbering Good Fair Average Poor Evaluate this document Editorial Language vocabulary readability clarity technical accuracy content Good Fair Average Poor Please check suggestions to improve this document Your suggestions to Improve introduction Make more concise improve the Improve Contents Add more step by step procedures tutorials document Improve arrangement Add...

Page 4: ... E1 Module CE1 Series 21 1 port Channelized E1 Module 1CE1 22 Non channelized E1 Module E1 Series 22 11 port Non channelized E1 Module 1E1 23 Frequency band MODEM M336 Series 23 11 port 33 6K Frequency band MODEM 1M336 25 ISDN U Series 1 port ISDN U Module 1U 25 26 IP Module VOP VOS Series 26 1 port IP Phone Module 1VOP 27 2 port IP Phone Module 2VOP 28 1 port Switch IP Phone Module 1VOS 29 2 port...

Page 5: ...rs Accessories 39 Tools Equipment 40 System Installation 40 Preparations 40 Tools 40 Checking Cabinet 42 Checking Routers Accessories 42 Installing Router 44 Main Control Board Cable Connection 44 Console Port Connection 44 Grounding Wire Connection 45 Connecting Power Supply 47 Module Installation 47 Module Installation Steps 48 Module Interface Cable Connection 53 Cables 53 Ethernet Interface Ca...

Page 6: ... have problems or questions regarding your product please contact us by e mail at overseas mail maipu com You can also call our Overseas Business Department over 86 28 85148850 85148041 85148050 85148750 and 85148997 Documentation Support Maipu Communication Technology Co Ltd welcomes comments and suggestions on the document usefulness For further queries or suggestions contact us by e mail overse...

Page 7: ...ng capacity from LAN to WAN It can be used to access multi Ethernet nodes such as network ends PC and video monitor in finance securities insurance and government industries The router provides many software features such as SNA DLSw VoIP VPN MPLS multicast MAC address binding and access control and bandwidth restriction The series provides backup schemes and QoS features It can be applied to mult...

Page 8: ...rt and asynchronous port to access large capacity Ethernet devices and traditional terminals Hierarchical QoS ensures that the priorities of various services can be realized on specified bandwidth of MSTP 100M port Supports MPLS and L2TPv3 to provide strict network area division for a single line bearing multiple services Integrates routing switching security voice transmission storage and wireles...

Page 9: ... diagnosing router faults to realize Zero spot service Inbuilt dial up modem console port is connected to an external dial up modem for remote login Switch to remote configuration mode via button Then users and manufacturers can maintain devices anywhere via telephone line dial up to realize Zero spot service MP2800 supports Maipu intelligent NMS for diagnosing and fixing router faults automatical...

Page 10: ...nals and large capacity Ethernet devices in network nodes branch offices Hierarchical QoS The priorities of various services can be realized on specified bandwidth of MSTP 100M port MP2800 supports narrowband lines and MSTP MPLS broadband lines For MSTP MPLS the lines are for 100M interfaces but in fact the bandwidth applied by users is only a part such as 2M 5M 10M 20M and 50M Inconsistency betwe...

Page 11: ...d with inbuilt 802 1X and firewall The series provides access authentication of users and network devices in branch offices and supports ACL packet filtering NAT certification audit routing verification callback and refusing service protection The router is the first in China to realize SNA DLSw and LLC2 protocols It is compatible with network devices of main manufacturers in the industry Structur...

Page 12: ...Configuration AUX port data receiving indicator FE0 WAN Ethernet 0 100M 10 100M Ethernet interface data rate indicator On 100M Off 10M ACT Ethernet interface data receiving sending indicator FE1 WAN Ethernet 1 100M 10 100M Ethernet interface data rate indicator On 100M Off 10M ACT Ethernet interface data receiving sending indicator LAN Ethernet 0 23 Yellow left 10 100M Ethernet interface data rate...

Page 13: ...MP2800 Series Router Installation Manual Version 1 0 MP2800 Router Back Panel MP2800 series router back panel interface configuration Maipu Confidential Proprietary Information Page 14 of 55 ...

Page 14: ...lti functional slot MP2806 MP2816 S2 S5 Decided by interface module VOP VOS 8AX 1STA modules Private slots ON OFF Power supply switch right OFF left ON INPUT AC 100 240V 1A input MP2818 S0 S7 Decided by interface module Multi functional module Multi functional slot For the slots of MP2806 and MP2816 only VOP VOS series voice card module 8AX and 1STA modules can be inserted The multi functional slo...

Page 15: ...816 8 MP2818 0 MP2804 4 MP2806 Private slot 4 MP2816 0 MP2818 0 MP2804 0 MP2806 AIM slot 0 MP2816 1 MP2818 Processor High speed RISC processor MONITOR 512Kbytes 32Mbytes MP2804 32Mbytes MP2806 FLASH 64Mbytes MP2816 64Mbytes MP2818 SDRAM 64Mbytes 128Mbytes 256Mbytes optional Dimension 444mm 320mm 44 5mm W D H Maximum weight 5 7KG Power supply input AC 100 240V 50 60Hz voltage AC 40V 57V 0 40 Enviro...

Page 16: ...witching HDLC LAPB ISDN Virtual Ethernet bridge Bridge PPPoE LAN is Ethernet supporting two kinds of link layer frame Ethernet II Ethernet SNAP Dialup network MODEM dialup calling callout CALLBACK Dial on demand Dialup backup Routing protocol Static routing Dynamic routing RIPv1 RIPv2 OSPF BGP IS IS IRMP Policy routing Multicast IGMP PIM SM PIM SSM PIM DM DVMRP Hot backup VRRP VBRP compatible with...

Page 17: ... Chinese English prompt and help information Detailed debugging information for network malfunction elimination Log in and manage other products by Telnet Download and upload configuration file and application program via FTP Download and upload configuration file and application program via TFTP Colorful debugging information support Support log function Security IP packet filter firewall Configu...

Page 18: ...rface Module SAE Series 11 port High speed V 24 V 35 Serial Module 1SAE 1SAE module is used for MP2800 router Its main function is to complete data flow receiving sending and processing For sync port 2 048Mbps in DCE mode and 8 Mbps in DTE mode For async port 115 2Kbps The working mode by default is in sync mode In DTE mode it uses clock from external DCE equipment such as external Maipu Confident...

Page 19: ...able 1SAE module connected cable is V35 DTE and V24 DTE 1SAE Interface Attributes 1 port high speed V 24 V 35 serial module 1SAE interface attributes Description Attributes Sync Async Tie in DB25 DB25 DB25 DB25 V 24 V 35 EIA TIA 232 Interface standard working mode DTE DTE DCE DCE Minimum BR bps 1200 1200 300 Maximum BR bps 128K 8M 115 2K Dialup Backup Protocol Service X25 HDLC PPP HDLC SLIP PPP FR...

Page 20: ...s CE1 interface it can be divided into 1 31 timeslots and each group works an interface after binding 1CE1 Interface Module Indicator 1CE1 interface module 1 port channelized E1 module 1CE1 1 port channelized E1 module 1CE1 indicator LOS Lost indicator On Cannot check sync signal Off After sync 1CE1 Module Connected Cable Coaxial line with BNC pin and RJ45 RJ45 connected twisted pair Maipu Confide...

Page 21: ...on channelized E1 Module E1 Series 11 port Non channelized E1 Module 1E1 The 1 port non channelized E1 module provides 2 048 Mbit s data transmission port E1 is same as CE1 interface which can be divided into 32 timeslots physically The timeslot 0 of E1 can be used for data transmission in unframed mode for 2M transparent transmissions 1E1 Module Indicator 1E1 module 1 port non channelized E1 modu...

Page 22: ...nterface BNC RJ45 cannot be used together One group for each Number of interfaces Interface standard G 703 Supported service X 25 FR Supported protocol PPP HDLC Frequency band MODEM M336 Series 11 port 33 6K Frequency band MODEM 1M336 The 1 port 33 6K frequency band MODEM supports sync or async mode It can work in private line or dialup line mode The modem can serve as the caller and callee In syn...

Page 23: ...ace mode Console port mode ON OFF LINE port is used as CONSOLE port Configure router via dialup remote login 1M336 Interface Module Connected Cable 1M336 module connected cable is RJ45 4 5 signal wire or RJ11 telephone line 1M336 Interface Attributes 1M336 interface attributes 1 port 33 6K frequency band MODEM 1M336 attributes Attributes Description Tie in RJ45 Number of 1 interfaces Supported lin...

Page 24: ...cator and it is on when running normally B1 B1 channel indicator and it is on when using channel B1 with the rate of B1 64K or B1 B2 128K B2 B2 channel indicator and it is on when using channel B2 with the rate of B2 64K or B1 B2 128K 1 port ISDN U module 1U DIP switch DIP switch configuration Mode 1 Description 2 Loopback ON Reserved 1U Module Connected Cable 1U module connected cable is RJ45 4 5...

Page 25: ...an access any telephone in IP network through dialup You can easily make a free phone call by using the set IP network constructing value added network 1VOP Module Indicator 1VOP interface module 1 port IP phone module 1VOP indicator V1 IP phone module indicator The light is on during the call V2 1VOP module may not have this light If it has the light will be not on 1VOP Module Connected Cable 1VO...

Page 26: ...ess any telephone in IP network through dialup You can easily make a free phone call by using the set IP network constructing value added network 2VOP Module Indicator 2VOP module 2 port IP phone module 2VOP 2 port IP phone module 2VOP indicator V1 IP phone module indicator Light on After pickup during the call V2 IP phone module indicator Light on After pickup during the call 2VOP Module Connecte...

Page 27: ...can access any telephone in IP network through dialup You can easily make a free phone call by using the set IP network constructing value added network 1VOS Module Indicator 1 port switch IP phone module 1VOS 1 port switch IP phone module 1VOS indicator V1 IP phone module indicator Light on during the phone call V2 1VOS module may not have this lamp Otherwise the lamp will never be on 1VOS Module...

Page 28: ...ule 2VOS The 2 port switch IP phone module can access any telephone in IP network through dialup You can easily make a free phone call by using the set IP network constructing value added network 2VOS Module Indicator 2VOS module 2 port switch IP phone module 2VOS 2 port switch IP phone module 2VOS indicator V1 IP phone module indicator Light on During the phone call V2 IP phone module indicator L...

Page 29: ...2VOS interface attributes Attributes Description Interface RJ45 jack two RJ11 plugs Number of 2 RJ11 interfaces Supported protocols H 225 H 245 RTP RTCP G 711 G 723 G 729 Ethernet Module ETE Series 1 port Ethernet Module 1ETE 1 port Ethernet module realizes Ethernet connection 1ETE Module Indicator 1ETE module 1 port Ethernet module 1ETE Maipu Confidential Proprietary Information Page 30 of 55 ...

Page 30: ...5 twisted pair 1ETE Module Interface Attributes 1ETE module interface attributes 1 port Ethernet port 1ETE attributes Attributes Description Tie in RJ45 Number of tie ins 1 Supported protocol 802 3 ISDN S T Module ST Series 11 port ISDN S T Module 1ST 1 port ISDN S T 1ST module provides 64K or 128K high speed access and backup 1ST Module Indicator 1ST module 1 port ISDN S T module 1ST Maipu Confid...

Page 31: ...erface Attributes 1 port ISDN S T module 1ST interface attributes Attributes Description Tie in RJ45 Number of tie ins 1 Supported protocol PPP ISDN S T Module STA Series 1 port ISDN S T Module 1STA 1 port ISDN S T 1STA module provides 64K or 128K high speed access and backup It is the hardware upgrade version of 1 port ISDN S T 1ST module with great slot compatibility and can be inserted to all t...

Page 32: ... 1STA Module Connected Cable 1STA cable is RJ45 straight through cable 1STA Module Interface Attributes 1 port ISDN S T module 1STA interface attributes Attributes Description Tie in RJ45 Number of tie ins 1 Supported protocol PPP Asynchronous Serial Module A Series 8 async Serial Module 8AX The 8 async module main function is to complete its data flow receiving and sending only in asynchronous mo...

Page 33: ...erface attributes Attributes Description Tie in DB60 Interface standard RS 232 Minimum BR bps 300 Maximum BR bps 115 2K Supported services Terminal with terminal number fixed function ATM PC working station Router Frequency band or base band modem PC or router dialup Other serial equipment Supported protocols X 25 HDLC PPP SLIP Maipu Confidential Proprietary Information Page 34 of 55 ...

Page 34: ...wap interface modules and interface cards of routers Do not hot swap cables Connect the interface cables of routers correctly especially do not connect phone lines including ISDN lines to serial ports Pay attention to the laser use security for example do not keep eyes open at the optical emitting mouth of LASER or the fiber connecter Use Uninterrupted Power Supply UPS Router AC power supply is so...

Page 35: ...ricity appears easily which harms the circuits on the router If the temperature is too high the reliability of the router reduces greatly The long time high temperature affects the life and speeds up the aging of insulation materials The recommended temperature and humidity in computer room Temperature Relevant humidity Long term Short term Long term Short term 15 30 0 40 40 65 10 90 Measuring poi...

Page 36: ...armful gases speed up the eroding of metals and the aging of some components The specific limitations are as follows Gas Maximum value mg m 3 SO 0 2 2 H S 0 006 2 NH 0 05 3 Cl 0 01 2 Anti static MP2800 router takes lots of measures in anti static but when the static exceeds a certain volume the circuits even the whole monitor are damaged For router communication static electricity originates from ...

Page 37: ...output lines Therefore pay attention to the following Take anti electric network interference for power system The router working place had better not be used with the grounding settings of power devices or anti thunder grounding settings and the distance between them had better be as long as possible Be away from the strong power radio transmitters radar transmitter and high frequency high curren...

Page 38: ... the input end of signal lines Check Routers Accessories After ensuring the installation environment requirements are met you can open the package However before installation check whether the router and the accessories are complete according to the purchase order Tools Equipment Tools Slotted point screwdriver cross point screwdriver Level ruler or tapeline Anti static equipment Connected cables ...

Page 39: ...ent Checking Cabinet Maipu devices are designed according to the dimension of 19 inch standard cabinet so they can be installed and fixed normally on 19 inch standard cabinet Before installation reserve enough slot room for installing the device Center distance of the horizontal installation hole and net horizontal direction installation space of the cabinet Maipu Confidential Proprietary Informat...

Page 40: ...t be installed on the pallets or trays used in pairs of the cabinet Therefore install the pallets or trays on the cabinet before installing the device as follows Use the level to check whether the pallets or trays are horizontal If not adjust the fixed bolt of pallet or tray to make the pallet or tray horizontal and then fasten it Check whether the floating nut for fixing the device is installed i...

Page 41: ...ar away from the places with liquids toxic gases and dust to avoid damages on the router When moving or checking the device wear gloves to avoid the corrosion of metal parts caused by perspiration Keep all packaging materials for later use during transporting Installing Router Install MP2800 router to the cabinet as follows Step 1 Wear gloves and anti static wrist and make the anti static reliable...

Page 42: ...talled on the bracket fixedly and straight Step 7 Check the space between the installed devices Choose the desired cabinet baffle board it is the standard accessory of the shelf to be placed in the space between the devices Use the screws to fix baffle board on the shelf Installation suggestions When installing various devices on a cabinet consider installing heavy devices at the bottom of the cab...

Page 43: ...tter is more common Step 2 Ensure that router or terminal is out of power supply and connect RS 232 serial and console port with cables During the connection make sure about the ID on the interface to avoid inserting to other interfaces Grounding Wire Connection The normal connection of MP2800 ground wire is the first guarantee of anti thunder and anti interference of the router It is required tha...

Page 44: ... a low requirement for input AC In China adopt 220V and 50Hz AC which is a civilian electricity standard Different areas have different power supply systems MP2800 router input power supply requirements are as follows AC input power supply 100 240V 50 60Hz DC input power supply 40 57V Maximum power 27W 10 MP2804 35W 10 MP2806 42W 10 MP2816 52W 10 MP2818 When connecting power supply use the below s...

Page 45: ...220V 50Hz 60Hz and use the clip to lock the cable for DC router connect the power line to the post according to the description of panel silk screen on the interface The cross sectional area of the lead of the selected power line must be larger or equal to 2 mm2 Step 2 Put power supply switch to ON Step 3 Check whether the power supply indicator of the front panel is on If not repeat step 1 and 2 ...

Page 46: ...ient as follows Installing MP2800 series modules Steps for installing modules Choose the desired modules and interfaces for the corresponding relationship of modules and slots refer to the interface table of the back panel of MP2800 router Insert the module to slot Insert the module circuit board into interface card slot Push in the module close to back panel Tighten the screw According to the con...

Page 47: ...the DCE side provides the synchronization clock and specifies the communication rate while DTE device receives the synchronization clock and communicate according to the specified baud rate The router usually serves as DTE For the type of the device connected to the router refer to the manual of the device The following table can also help you determine the device type Typical DTE and DCE equipmen...

Page 48: ...r 64Kbps Connect the cables of synchronous asynchronous modules as follows Step 1 Insert one side of DB 25 to the DB 25 interface of 1SAE module and screw down fixed knob Step 2 Connect another DB25 interface to V 24 V 35 DB 25 M 34 cable and then connect the following equipment If WAN is DDN line connect V 35 cable to digital Modem V 35 interface If WAN is dialup line connect V 24 cable to analog...

Page 49: ...5 straight twisted pair to connect BNC and RJ45 interface cannot be used together During the connection make sure about the ID on the interface to avoid inserting to other interfaces which causes the damage of modules and router host For E1 module asynchronous indicator is always on in transparent 2M mode in non transparent mode the indicator is on when frame synchronous signals are not checked Af...

Page 50: ...When having the phone call pay attention to the indicator of 1VOP 2VOP card back panel The indicator and Active light should be on During the connection make sure about the ID on the interface to avoid inserting to other interfaces which causes the damage of modules and router host 1VOS 2VOS Module Interface Cable Connection Inset telephone line to RJ11 RJ45 interface of 1VOS 2VOS and another side...

Page 51: ... and router host 1ST 1STA Module Interface Cable Connection Inset RJ45 plug of 1ST 1STA cable to RJ45 jack Connect another side of RJ45 plug to equipment wire 8AX Module Interface Cable Connection Inset DB60 plug of 8AX cable to 8AX jack Screw down the fixed knob Connect another side of RJ45 plug to equipment wire During the connection make sure about the ID on the interface to avoid inserting to ...

Page 52: ...5 twisted pair connection relation RJ45 Signal Direction RJ45 Description Length 1 TX0 1 Twisted pair 1 2 TX0 2 3 RX0 3 Twisted pair 2 6 RX0 6 4 4 2m Twisted pair 3 5 5 7 7 Twisted pair 4 8 8 RJ45 cross cable type 5 twisted pair connection relation RJ45 Signal Direction RJ45 Description Length 1 TX 3 2 TX 6 Twisted pair 1 3 RX 1 6 RX 2 Twisted pair 2 4 7 2m 5 8 Twisted pair 3 7 4 8 5 Twisted pair ...

Page 53: ...al jack and it is 8 core non screen cable One side is RJ45 plug and another is DB9 hole 5 4 3 2 1 9 8 7 6 RJ45 jack Standard DB9 interface Console port cable connection relation RJ45 Signal Direction DB9 Length 1 CTS 8 2 DSR 6 3 RXD 2 4 GND 5 5 6 TXD 3 7 DTR 4 8 RTS 7 1 3m 9 Maipu Confidential Proprietary Information Page 54 of 55 ...

Page 54: ...ing RJ45 interface of E1 card use RJ45 RJ45 cross twisted pair Make the cables according to the cable sequence described in the following table E1 and CE1 using RJ45 RJ45 cross twisted pair RJ45 Signal Direction RJ45 1 RX 4 2 RX 5 3 7 6 8 4 TX 1 5 TX 2 7 3 8 6 Maipu Confidential Proprietary Information Page 55 of 55 ...

Reviews: