1M336 Module Cable Connection  

ƒ

 

Inset RJ11 plug of 1M336 module cable to LINE jack.  

1M128 Module Cable Connection  

ƒ

 

Inset RJ11 plug of 1M336 module cable to LINE jack, and another side 
with external wire.  

 

ƒ

 

After power on, check ACT status of 1M128 module, and if indicator is 
not on, check the circuit.  

Connecting 1STA Module Cable 

 

ƒ

 

Inset RJ45 plug of 1STA module cable to RJ45 jack 

 

ƒ

 

Connect another side of RJ45 plug to equipment wire

 

1U Module Cable Connection 

ƒ

 

Inset RJ11 plug of 1U module cable to LINE jack, and another side with 
external wire  

 

ƒ

 

After power on, check ACT status of 1U module, and if indicator is not 
on, check the circuit.

 

Connecting 1VOP/2VOP Module Cable 

 

ƒ

 

Inset telephone line to RJ11/RJ45 interface of 1VOP/2VOP, and another 
side to telephone.  

 

ƒ

 

When having the phone call, pay attention to the indicator of 
1VOP/2VOP card back panel. The indicator and Active light should be 
on.  

 

Summary of Contents for MP1800-3

Page 1: ...57 MP1800 3 Router Installation Manual Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue Hi Tech Park Chengdu Sichuan Province P R China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 URL http www maipu com Mail overseas maipu com ...

Page 2: ...this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes Maipu values and appreciates comments you may have concerning our products or this document address comments to Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue Hi Tech Park Chengdu Sichuan Province P R China 610041 Tel 86 28 85148850 85148041 Fax 8...

Page 3: ...ement appearance Good Fair Average Poor Accessibility Contents index headings numbering Good Fair Average Poor Evaluate this document Editorial Language vocabulary readability clarity technical accuracy content Good Fair Average Poor Your suggestions to improve the document check suggestions to improve this document Improve introduction Make more concise Improve Contents Add more step by step proc...

Page 4: ...nelized E1 Module CE1 Series 20 1 port Channelized E1 Module 1CE1 20 Non channelized E1 Module E1 Series 21 1 port Non channelized E1 Module 1E1 21 Frequency band MODEM M336 Series 23 1 port 33 6K Frequency band MODEM 1M336 23 Base band MODEM M128 Series 25 1 port 128K Base band MODEM 1M128 25 ISDN S T Module STA Series 27 1 port ISDN S T Module 1 STA 27 ISDN U Series 28 1 port ISDN U Module 1U 28...

Page 5: ...g Wire Connection 48 Module Installation 48 Connecting Back Panel 49 Hardware Installation 49 Module Interface Cable Connection 50 1SAE Module Interface Cable Connection 50 Connecting 1CE1 1E1 Module Cable 52 1M336 Module Cable Connection 53 1M128 Module Cable Connection 53 Connecting 1STA Module Cable 53 1U Module Cable Connection 53 Connecting 1VOP 2VOP Module Cable 53 Connecting 1VOS 2VOS Modul...

Page 6: ...cumentation and Maipu products Customer Support If you have problems or questions regarding your product contact us by e mail at overseas maipu com You can also call our Overseas Business Division over 86 28 85148850 85148041 85148050 85148750 and 85148997 Documentation Support Maipu Communication Technology Co Ltd welcomes comments and suggestions on the document usefulness For further queries or...

Page 7: ...AN It can be used to access multi Ethernet nodes such as network ends PC and video monitor in finance stocks insurance and public sector industries MP1800 3 8FE router provides software features such as VoIP VPN MPLS multicast MAC address binding and access control and bandwidth restriction It provides backup schemes and QoS features It can be widely applied to multiple services such as data video...

Page 8: ...e narrowband access MP1800 3 8FE router integrates the features of previous narrowband routers and provides two high speed MIMs and one VoIP slot to realize the expansion of private leased line dialing backup and VoIP The router provides multi Ethernet access for expansion of broadband It realizes the high bandwidth access of multi Ethernet nodes such as network ends PC and video monitor so that u...

Page 9: ...MPLS protocols It supports L2TP and IPsec The router adopts technologies to deploy different VPN networks from L2 to L3 The router is inbuilt with firewall and provides advanced security features such as ACL packet filtering NAT authentication audit route verification callback and refusing service protection It provides integrated services and distinguished services and supports ACR FIFO PQ CQ FQ ...

Page 10: ...Page 10 of 57 Hardware Appearance MP1800 series router appearance ...

Page 11: ...ower on FAN Fan indicator On Normal working Off Malfunction SLOT2 Slot 2 status indicator ACT Data receiving sending indicator RDY On on line SLOT1 Slot 1 status indicator ACT Data receiving sending indicator RDY On on line SLOT 0 Slot 0 status indicator ACT Data receiving sending indicator RDY on on line CONSOLE console port TXD console port data sending indicator RXD console port data receiving ...

Page 12: ...ernet interface data rate indicator On 100M Off 10M ACT Ethernet interface data receiving sending indicator FETH0 WAN Ethernet 0 100M 10 100M Ethernet interface data rate indicator On 100M Off 10M ACT Ethernet interface data receiving sending indicator ...

Page 13: ... Power supply switch right OFF left ON INPUT AC 100 240V 1A input DC 40 57V 27W SLOT2 special Bus slot VOP VOS VoIP module SLOT1 Decided by interface module Bus slot MIM module SLOT0 Decided by interface module Bus slot MIM module SLOT2 is VoIP module slot It has inset VOP VOS series VoIP card module SLOT1 and SLOT0 are MIM slots with modular design MP1800 3 Router Front Panel Interface ...

Page 14: ...hernet interfaces RJ45 MIM slot Two MIM slots Special slot One VOP VOS slot Processor High speed RISC processor FLASH 32Mbyte MP1800 SDRAM 128Mbyte MP1800 Dimension W D H 444mm 318mm 44 5mm Weight 4 5 Kg Power supply input voltage DC 40 57V Environment temperature 0 40 Environment humidity 10 90 Non condensing Maximum power 27W 10 MP1800 ...

Page 15: ...ernet SNAP Dialup network MODEM dialup calling callout CALLBACK Dial on demand Dialup backup Routing protocol Static routing Dynamic routing RIPv1 RIPv2 OSPF BGP IRMP compatible with CISCO EIGRP SNSP compatible with CISCO ODR Dial on demand DDR Policy routing Multicast IGMP PIM SM PIM DM DVMRP Hot backup VRRP VBRP compatible with CISCO HSRP Network service ARP Proxy ARP L2TP Configuration command ...

Page 16: ...mote login via local Telnet Configuration command security isolation function Chinese English prompt and help information Detailed debugging information for network malfunction elimination Login and manage other products by Telnet Download and upload configuration file and application program via FTP Download and upload configuration file and application program via TFTP Colorful debugging informa...

Page 17: ...800 3 Router Installation Manual Page 17 of 57 Modules MP1800 3 router is a modular router with three slots The current interface module provides 1SAE 1CE1 1E1 1M336 1M128 1U 1VOP 2VOP 1VOS 2VOS 1ETE 1STA ...

Page 18: ...in sync mode In DTE mode it uses clock from external DCE equipment such as external sync modem But in DCE mode router provides clock 1SAE Interface Module 1SAE interface module 1 port high speed V 24 V 35 serial module 1SAE 1SAE Module Connected Cable 1SAE module connected cable is V35 DTE and V24 DTE 1SAE Interface Attributes 1SAE module interface attributes is as table 2 1 Table 2 1 1 port high ...

Page 19: ...MP1800 3 Router Installation Manual Page 19 of 57 mode DTE DCE DTE DCE Minimum BR bps 1200 1200 300 Maximum BR bps 128K 8M 115 2K Dialup Backup Protocol Service X25 HDLC PPP SLIP FR LAPB HDLC PPP SLIP ...

Page 20: ...sion rate 1984K When used as CE1 interface it can be divided into 1 31 timeslots and each group works an interface after binding 1CE1 Interface Module Indicator 1CE1 interface module 1 port channelized E1 module 1CE1 1 port channelized E1 module 1CE1 indicator LOS Lost indicator On Cannot check sync signal Off After sync 1CE1 Module Connected Cable 1CE1 BNC pin coaxial line and RJ45 RJ45 connected...

Page 21: ...h Interface standard G 703 Protocol PPP X 25 HDLC FR Non channelized E1 Module E1 Series 1 port Non channelized E1 Module 1E1 The 1 port non channelized E1 module provides 2 048Mbit s data transmission port E1 is same as CE1 interface which can be divided into 32 timeslots physically The timeslot 0 of E1 can be used for data transmission in unframed mode for 2M transparent transmissions ...

Page 22: ... On Non transparent and cannot check frame sync signal Off After sync 1E1 Interface Connected Cable 1E1 and BNC pin coaxial cable and RJ45 RJ45 connected twisted pair 1E1 Interface Attributes 1 port non channelized E1 1E1 attributes Attributes Description Interface BNC RJ45 cannot be used together Interface number 1 group Interface standard G 703 Supported service X 25 FR Supported protocol PPP HD...

Page 23: ...ync mode 1M336 Interface Dialup DIP 1M336 interface module 1 port 33 6K frequency band MODEM 1M336 1 port 33 6K frequency band MODEM 1M336 DIP DIP switch configuration Mode 1 2 Description Frequency band MODEM mode OFF OFF LINE port is used as inbuilt frequency band MODEM interface Console port mode ON OFF LINE port is used as CONSOLE port Configure router via dialup remote login ...

Page 24: ... connected cable is RJ45 4 5 signal wire or RJ11 telephone line 1M336 Interface Attributes 1M336 interface attributes 1 port 33 6K frequency band MODEM 1M336 attributes Attributes Description Tie in RJ45 Interface number 1 Supported link protocol PPP Frame relay X 25 HDLC Supported network protocol IP ...

Page 25: ...and MODEM 1M128 Indicators 1 port 128K base band MODEM 1M128 indicator ACT On Link established B1 B1 channel indicator Light on When using channel B1 and rate is 64K B2 B2 channel indicator Light on When using channel B2 and the rate is 128K DIP switch description is as table 2 9 1 port 128K base band MODEM 1M128 DIP DIP switch configuration Mode 1 2 Description Loopback ON Reservation ...

Page 26: ...ule connected cable is RJ45 4 5 signal cable or RJ11 line 1M128 Interface Attributes 1M128 interface attributes 1 port 128K base band MODEM 1M128 interface Attributes Description Tie in RJ45 Interface number 1 Supported link protocol PPP Frame relay X 25 HDLC Supported network protocol IP ...

Page 27: ...r ACT Activated indicator and it is on when operates normally B1 B1 channel indicator and it is on when using channel B1 with the rate of B1 64K or B1 B2 128K B2 B2 channel indicator and it is on when using channel B2 with the rate of B2 64K or B1 B2 128K 1 STA Module Connected Cable 1 STA cable is RJ45 connected Ethernet cable 1 STA Module Interface Attributes 1 port ISDN S T module 1 STA interfa...

Page 28: ...ter Installation Manual Page 28 of 57 ISDN U Series 1 port ISDN U Module 1U 1 port ISDN U module connects DDN network and ISDN network It will not connect modem 1U Module Indicator 1U module 1 port ISDN U module 1U ...

Page 29: ...Light on When using channel B2 and the rate is 128K 1 port ISDN U module 1U DIP switch DIP switch configuration Mode 1 2 Description Loopback ON Reservation 1U Module Connected Cable 1U module connected cable RJ45 4 5 signal cable or RJ11 line 1U Interface Attributes 1 port ISDN U module 1U interface attributes Attributes Description Tie in RJ45 Interface number 1 Supported link protocol PPP Suppo...

Page 30: ...rk You can easily make a free phone call via IP network 1VOP Module Indicator 1VOP interface module 1 port IP phone module 1VOP indicator V1 IP phone module indicator The light is on during the call V2 1VOP module may not have this light If it has the light will be not on 1VOP Module Connected Cable 1VOP module connected cable is RJ45 4 5 signal cable and RJ11 line ...

Page 31: ... H 245 RTP RTCP G 711 G 723 G 729 2 port IP Phone Module 2VOP The 2 port IP phone module accesses any call in IP network via dialup You can make free phone call via IP network 2VOP Module Indicator 2VOP module 2 port IP phone module 2VOP 2 port IP phone module 2VOP indicator V1 IP phone module indicator Light on After pickup during the call V2 IP phone module indicator Light on After pickup during...

Page 32: ...erface attributes Attributes Description Interface RJ45 jack two RJ11 plugs Interface No 2 RJ11 Supported protocol H 225 H 245 RTP RTCP G 711 G 723 G 729 1 port Switch IP Phone Module 1VOS The 1 port switch IP phone module accesses any phone in IP network via dialup or second dialup You can easily make free phone calls via IP network 1 1VOS Module Indicator 1 port switch IP phone module 1VOS ...

Page 33: ...during the phone call V2 1VOS module may not have this lamp Otherwise the lamp will never be on 1VOS Module Connected Cable 1VOS module connected cable is RJ45 4 5 signal cable and RJ11 line 1VOS Interface Attributes 1 port switch IP phone module 1VOS interface attributes Attributes Description Interface RJ45 jack Interface No 1 Supported protocol H 225 H 245 RTP RTCP G 711 G 723 G 729 ...

Page 34: ...port switch IP phone module 2VOS 2 port switch IP phone module 2VOS indicator V1 IP phone module indicator Lamp on During the phone call V2 IP phone module indicator Lamp on During the phone call 2VOS Module Connected Cable 2VOS module connected is RJ45 2VOS Module Interface Attributes 2 port switch IP phone module 2VOS interface attributes Attributes Description Interface RJ45 jack Interface numb...

Page 35: ...nterface Module Connected Cable The cables of 8AX module adopt 8 port asynchronous serial port cable 8AX Module Interface Attributes 8AX module interface attributes is as follows Attributes Description Tie in DB60 Interface standard RS 232 Minimum Baud rate bps 300 Maximum Baud rate bps 115 2K Supported services Connect to terminals with the function of fixing terminal numbers Connect to ATM Conne...

Page 36: ...MP1800 3 Router Installation Manual Page 36 of 57 PPP SLIP ...

Page 37: ...router maintain stable temperature and humidity in the equipment room MP1800 3 router must be used indoor The requirements for the indoor environment are as follows Environment temperature 0 40 C Humidity 10 90 non condensing MP1800 3 router is configured with the cooling fan The cooling theory is With the effect of the fan the cold air enters the device from the right of the chassis and drawn out...

Page 38: ...ads shrink which causes the fastened screws loose Meanwhile in dry environment static electricity appears easily which harms the circuits on the router If the temperature is too high the reliability of the router reduces greatly The long time high temperature affects the life and speeds up the aging of insulation materials The recommended temperature and humidity in equipment room Temperature Rele...

Page 39: ...ch as floor material and chassis structure To prevent the damage caused by the static do as follows Ensure proper equipment grounding Maintain dustproof room Keep suitable temperature humidity Wear anti static equipment Place the disassembled circuit board on the anti static workstation and keep the face upturned or in the anti static bag When viewing or removing the disassembled circuit board tou...

Page 40: ...ters Accessories After ensuring the installation environment requirements are met you can open the package However before installation check whether the router and the accessories are complete according to the purchase order If some goods are lost or damaged please contact the dealer or salesman at once During the check place the device and accessories in the safe place to prevent the device from ...

Page 41: ...cuments 1 Installation manual and configuration manual CD Installation accessories 1 A pair of brackets and a set of screws Product packaging 1 Including foam anti shocking material and external packing box plastic bag etc Chassis Installation Tools Equipment Tools Screwdriver Anti static wear Glove Connected cable Console port cable Ethernet cable MP1800 3 Ethernet cable is configured according t...

Page 42: ... Machine Installation MP1800 3 dimensions 444mm 318mm 44 5mm W D H Check the rack Give enough empty slot space for equipment before installation Use ruler or tapeline to measure space between installation hole center distance and horizontal direction ...

Page 43: ...d nut and empty baffle Install equipment on rank splint and bracket Install splint and bracket in rank Splint or bracket installation Check whether floating nut is installed If not inset it into hole Note One device should be put on one splint or bracket Do not keep several devices together ...

Page 44: ...stalling equipment on bracket MP1800 3 installing to bracket Wear gloves and ensure proper grounding Put device on flat surface and aim at bracket installation hole to the side hole and then use bolt to fix Check whether the bracket is fixed and straight ...

Page 45: ...ation hole to the side hole and then use bolt to fix Operator should face the equipment to keep the device level with both hands Push device inside with hands Use fixed bolt to install device on the rack Check whether device is fixed and straight Check the space between installed devices choose rack baffle to put among the devices and then use bolt to fix To guarantee the radiation space among dev...

Page 46: ...aximum power consumption 27W 10 MP1800 Use the following power supply jack or multi functional PC power supply The following is the suggested power supply jack Ground wire Live wire Naught wire Connecting power supply Switch off MP1800 and connect one side of power supply cable to the entry of back panel of router and another side to power supply jack Switch power supply on Check whether power sup...

Page 47: ... power supply grounding Connecting Main Control Board Cable This section explains the method of connecting MP1800 3 router control board cable to network including connecting router console port Connecting Console Port MP1800 3 provides one EIA TIA 232 async serial console port The user configures router via this port by adopting RS 232 serial character terminal normally it is a PC Step 1 Find a c...

Page 48: ...le protects PSTN Connect this point and ground it by a thick cable with resistance not more than 4Ω If the router is installed on 19 inch standard rack ground the rack Module Installation The router adopts modular system structure and different kinds of interface configuration Module installation Choose the module and interface Inset module to slot The module circuit board should inset to interfac...

Page 49: ...of router power supply and another side to power supply jack Configure the router via console port after first power on Inset one side of configuration cable to console port and another side to PC or terminal serial Inset one side of Ethernet cable to LAN interface and another side to LAN Connect sync async communication cable to router WAN Interface MP1800 3 sync async interface works in the mode...

Page 50: ...rface Cable Connection This section explains important points in 1SAE module and cable connection Before connecting sync async serial ensure the type of equipment connecting sync async serial which is sync async DTE DCE Access the equipment required signal standard baud rate and sync clock DTE DCE Sync async serial usually accesses external Modem or TA terminal adapter as dialup interface Sync ser...

Page 51: ...tandards and baud rate in different working modes Choose cables according to prevailing conditions V 24 cable rate and transmission distance BR bps Maximum transmission distance m 2400 60 4800 60 9600 30 19200 30 38400 20 64000 20 115200 10 V 35 cable rate and transmission distance BR bps Maximum transmission distance m 2400 1250 4800 625 9600 312 19200 156 38400 78 56000 60 64000 50 2048000 30 Wh...

Page 52: ...35 interface If WAN is dialup line connect V 24 cable to analog Modem serial Connecting 1CE1 1E1 Module Cable Connect one side of BNC plug to BNC interface of 1CE1 E1 module Connect another side to relevant equipment TX should be connected with the RX equipment and RX should be connected with TX line Switch power on and check LOS status of 1CE1 E1 module If lamp is on there is malfunction and sign...

Page 53: ...le Cable Inset RJ45 plug of 1STA module cable to RJ45 jack Connect another side of RJ45 plug to equipment wire 1U Module Cable Connection Inset RJ11 plug of 1U module cable to LINE jack and another side with external wire After power on check ACT status of 1U module and if indicator is not on check the circuit Connecting 1VOP 2VOP Module Cable Inset telephone line to RJ11 RJ45 interface of 1VOP 2V...

Page 54: ...le Inset the DB60 plug of 8AX module cable to the socket Pay attention to the positive and negative directions Screw down the cable fixing button to fix the cable on the 8AX module socket Connect another RJ45 interface of the cable to relevant equipment wire Interface Cable Signal Ethernet Cable MP1800 3 Ethernet interface cable is 8 core non screen twisted pair Port1 2 is sending end and port 3 6...

Page 55: ...air 2 4 4 5 5 Twisted pair 3 7 7 8 8 Twisted pair 4 Table A 2 RJ45 crossing cable type 5 twisted pair connection relation RJ45 Signal Direction RJ45 Description Length 1 TX 3 2 TX 6 Twisted pair 1 3 RX 1 6 RX 2 Twisted pair 2 4 7 5 8 Twisted pair 3 7 4 8 5 Twisted pair 4 2m ...

Page 56: ...connected with PC 9 core serial jack and it is 8 core non screen cable One side is RJ45 plug and another is DB9 hole RJ45 jack Standard DB9 interface Console port cable connection relation RJ45 Signal Direction DB9 Length 1 CTS 8 2 DSR 6 3 RXD 2 4 GND 5 5 6 TXD 3 7 DTR 4 8 RTS 7 1 9 3m 4 3 2 1 8 7 6 5 ...

Page 57: ... 57 RM2 1E1 RM2 1CE1 Using RJ45 RJ45 Crossing Twisted pair When using E1 card RJ45 interface use RJ45 RJ45 crossing twisted pair E1 and CE1 using RJ45 RJ45 crossing twisted pair RJ45 Signal Direction RJ45 1 RX 4 2 RX 5 3 7 6 8 4 TX 1 5 TX 2 7 3 8 6 ...