Maintronic Casambi CRD400 INS Manual Download Page 26

MTC maintronic GmbH - Schweinfurt | Germany - www.maintronic.com

CRD400 INS - Manual

Date: 09.07.2021

Page 
25

WARNING

The signal word "WARNING" indicates a possibly imminent danger. If it is not avoided, death or very serious injuries may 
result.

CAUTION

The signal word "CAUTION" indicates a possibly imminent danger. If it is not avoided, slight or minor injuries may result.

ATTENTION

The signal word "CAUTION" indicates a situation that can lead to material damage. Either to the product itself or to other 
objects in the environment.

NOTE

The signal word "NOTE" indicates tips and recommendations to help you get the most out of the product.

Safety information

WARNUNG

For your own safety, read all instructions and information in this manual carefully before initial operation. Keep this 
manual for future reference.

The instructions are an integral part of the product and must be handed to the end customer.

All information and instructions in this manual must be observed completely and in detail. The manufactuer is not 

responsible for any direct or consequential damage that results from disregarding any information in this manual.

Summary of Contents for Casambi CRD400 INS

Page 1: ...trofit Dimmer Document date 09 07 2021 Document name 10273_MA_en_A4_CRD400_20210709 Manual english Carl Zeiss Str 10 14 97424 Schweinfurt Germany Tel 49 0 9721 7766 0 Fax 49 0 9721 7766 18 www maintro...

Page 2: ...rocedure 9 1 5 Commissioning 11 1 6 Operation 12 1 7 Configure push button input 14 1 8 Dimming characteristics 15 1 9 Dimming curve 16 1 10 Casambi Sensors and Parameters 18 1 11 Reset to factory def...

Page 3: ...nfurt Germany www maintronic com CRD400 INS Manual Date 09 07 2021 Page 2 Manual English CRD400 Casambi LED Retrofit Dimmer Technical Features Product Item number Valid from version Hardware Firmware...

Page 4: ...istics Dimming curve Operation Reset to factory default settings Product description Quick set up Connections and elements Calibration procedure FAQ Determining the number of luminaires which can be c...

Page 5: ...www maintronic com CRD400 INS Manual Date 09 07 2021 Page 4 Quick set up STEPS for a quick set up Step 1 Product description Step 2 Connection Step 3 Calibration procedure Step 4 Commisioning Step 5 O...

Page 6: ...with the Casambi APP Casambi App automatically identifies the device and can be integrated into existing networks All functions triggered by the buttons are individually configurable As soon as the de...

Page 7: ...MTC maintronic GmbH Schweinfurt Germany www maintronic com CRD400 INS Manual Date 09 07 2021 Page 6 With the integrated strain relief the installation in a junction box is not necessary...

Page 8: ...n input L Wiring 0 2 4mm starr single wire 0 2 2 5mm flexibel fine wire 0 5 2 5mm flexibel mit Aderendh lse fine wire with ferrule 6mm Connection diagram Elements Content of this page Connections Wiri...

Page 9: ...MTC maintronic GmbH Schweinfurt Germany www maintronic com CRD400 INS Manual Date 09 07 2021 Page 8 1 Device button 2 Status LED...

Page 10: ...wird nur der Phasenanschnittmodusverwendet und die Messung f r die Parameter der LED Lastkurve angewendet Wenn die Last mit Phasenanschnitt nicht dimmbar ist dann wird der Modus Zero Cross Switch ange...

Page 11: ...ce is used a new calibration can be started in the app via the Measure mode parameter and a calibration method is selected If the load used is not compatible with the selected load type the system swi...

Page 12: ...omatically identifies the device and can be integrated into existing networks All functions triggered by the buttons are individually configurable The following steps are necessary for this purpose Op...

Page 13: ...es Dr cken Function device button keystroke Switch On Off Dim the last stored brightness short press Dimming Up and Down Start at Min Level long press Switching to Max Level 2x short press The device...

Page 14: ...the button inputs may be configured Push button style Through the parameter Push button style the functionality of the button inputs are defined To change the push button style proceed as shown below...

Page 15: ...For example program switch with single function Select the item Controls a luminaire Tap on Luminaire Choose CRD400 By default the push button is configured to itself If another device or scene shoul...

Page 16: ...uit In case of a short circuit the unit switches off the output Every 30 seconds the unit tests whether the short circuit has been eliminated If it has the unit restarts automatically If the fault is...

Page 17: ...rs from different manufacturers are operated together Mode Dimming curve Value Type linear 0 linear curve default LED Picture added soon 1 maintronic custom curve incandescent Picture added soon 2 mai...

Page 18: ...MTC maintronic GmbH Schweinfurt Germany www maintronic com CRD400 INS Manual Date 09 07 2021 Page 17 Casambi Log 4 Casambi Compatibility mode...

Page 19: ...imming output 0 Load is switched off 1 179 Phase cut is applied 180 Load is switched permanently on 0 180 degree 360 System Status System Status Error Code From this error code the System Info is deri...

Page 20: ...hest priority is displayed Error Text Value Priority No error O K 0 Load output is open Open 1 1 Over temperature is active Overtemp 2 2 Load output has overvoltage Overvolt 4 3 Load output has a shor...

Page 21: ...ll flash After the reset an automatic calibration takes place Content of this page Step by step guide Related content Commissioning Operation Configure push button input Dimming characteristics Dimmin...

Page 22: ...eichnung Bedeutung Beispiele Typ Sensoren zeigen statatistische Werte oder technisch phy Seite CBA UP Casambi Jalousieaktor Link zur Produkthomepage des Moduls https casambi maintronic de casambi casa...

Page 23: ...andbuch Deutsch I J K Startseite Knowledge Base knowledgeBase Header png H ufig gestellte Fragen Ben tigen Sie weitere Hilfe Andere Ressourcen Nach Thema durchsuchen K rzlich aktualisierte Artikel Sei...

Page 24: ...te Test das ist ein Test https confluence maintronic com pages editpage action pageId XXX ID 144834619 U V W Seite Was ist der Unterschied zwischen den Fixtures Absolute shutter und Absolute shutter m...

Page 25: ...information onlinehelp as well as downloads for the product on our website Contact us if you have any problems or questions about your device Legals The division building automation and all associated...

Page 26: ...o the product itself or to other objects in the environment NOTE The signal word NOTE indicates tips and recommendations to help you get the most out of the product Safety information WARNUNG For your...

Page 27: ...nd accident prevention directives of the country Be sure that the existing mains voltage corresponds with the specified operating voltage before operating the device Risk of electric shock Do not oper...

Page 28: ...s C kapazitive Lasten elektronische Trafos capacitive loads electronic transformers Icon Beschreibung Description Astro Funktion steuert Szenen nach Sonnen Auf und Untergang Astro function control sce...

Page 29: ...e feste Sapnnung oder einen Arbeitsbereich z B 10 bis 24 V DC Powersupply DC Spannungsversorgung DC Batteriebetrieb m glich Powersupply DC battery possible Spannungsversorgung Versorgung ber DALI Powe...

Page 30: ...ese Symbole befinden sich in der Technischen Dokumenation des jeweiligen Ger tes The symbols explained here show the technical data of the devices These symbols can be found in the technical documenta...

Reviews: