Mainstreet Equipment 829BMR23R User Manual Download Page 5

5

Mainstreet Equipment

User Manual

Adjusting the temperature changes the minimum temperature your unit will run at . Your unit will not 
run constantly at this setting . To change it, follow these instructions:

•  Hold “SET” for 1 sec . The display will flash the current minimum temperature .
•  Use the arrow buttons to adjust the minimum temperature you want it to run at .
•  Press “SET” again to save your settings . 

Always remember to calculate the differential if you change the minimum temperature setting . The cabinet temperature 
will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs and shuts off . Setting the 
temperature too high will result in unsafe maximum temperatures and possible health code violations .  

 
Controller: 

set

mute

Freezer controllers are signified by a worded marking to the right of the screen .

RUNNING A MANUAL DEFROST CYCLE

This unit is pre-programmed to run automatic defrost cycles at preset intervals . However, if you would like to run a manual 
defrost cycle at any time, please follow the steps below: 
 
Refrigerators:
Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds . Repeat to stop the  
defrost cycle .

DEFROST SYSTEM

Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit) . During compressor down-time, the evaporator 
fan continues to circulate air through the evaporator coil . This air circulation raises the coil temperature above the freezing 
point, melting any accumulated frost . Run-off water is drained into the evaporator pan and evaporated . Freezer coils 
are defrosted electrically . Automatic defrost timers automatically initiate at pre-set intervals and for a pre-determined 
duration . 