Version
:
V1.0
(
2020.02
)
Copyright © 2020 Mainlink All Rights Reserved
18
Open
Mission Planner
,
select UDP
,
click the “connect” button, it will bring up a new
window ‘Listen port’
,
change the port to 14550
(
If the UDP port number has been changed
on the web page, please fill in the new number. For more information, please go to the web
page configuration
)
.Then click “OK”, Mission Planner will get flight data
。
5.2
Get data from TCP port.
Open
Mission Planner
,select TCP,click the “connect” button, it will bring up a
new
window ‘Listen port’
,
fill in the blank with IP: 192.168.1.236, remote port is 5760
(
If the IP address and TCP port number has been changed on the web page,
please fill in the new IP and port number. For more information, please go to the web page
configuration
)
.Then click “OK”, Mission Planner will get flight data.
5.3
Get data from UART(COM)
;
Connect the ground unit UART1 with a UART
(
TTL
)
to USB converter to the computer. Before this, please
install the driver in the computer.