25
7.3 Flooring
The boiler room floor must be flat and level and must be able to support boiler gross weight. The floor must
comply with the requirements of NFPA 31.
Generally the boiler should be placed on non-combustible floors. However, a shielding material can be placed
underneath the boiler and the chimney connector in the case of a combustible floor like shown on the follo-
wing drawing.
1
Boiler base plate
2
Spacer
3
Shielding material
The spacer must be able to support the weight of the boiler and has to be non combustable. The shielding
material must be equivalent to a R-value of 0.3 Km2/W or greater. For more information contact Maine Ener-
gy Systems.
R
Riissk
k o
off ffiirre
e::
The non-combustible flooring needs to extend out to
the clearances shown on the chart below.
Minimum clearances of shielding material required for
floor protection
Min. clearance of the shielding material
from the boiler back – Note also the local
restrictions in your area (a)
inch
17
Min. clearance of the shielding material
from the boilers left side panel (b)
inch
8
Min. clearance of the shielding material
from the boilers front panel (c)
inch
20
Min. clearance of the shielding material
from the boilers right side panel (d)
inch
12
Note:
The floor protection must extend under the chimney connector, at least 2 inches on either side.
Installation Manual AutoPellet Air Furnace 17 — 28
Summary of Contents for AutoPellet Air TOUCH 17
Page 42: ...42 Cable routing PE 603 USA_FA 1 0...
Page 43: ...Cable routing 43 Installation Manual AutoPellet Air Furnace 17 28...
Page 45: ...Wiring diagrams 45 Installation Manual AutoPellet Air Furnace 17 28...
Page 46: ...46 Wiring diagrams PE 603 USA_FA 1 0...
Page 47: ...Wiring diagrams 47 Installation Manual AutoPellet Air Furnace 17 28...
Page 70: ...70 Pellet Furnace cautionary markings PE 603 USA_FA 1 0...
Page 71: ...Pellet Furnace cautionary markings 71 Installation Manual AutoPellet Air Furnace 17 28...
Page 72: ...72 Pellet Furnace cautionary markings Labeling 105x74 PE 603 USA_FA 1 0...
Page 73: ...Pellet Furnace cautionary markings 73 Installation Manual AutoPellet Air Furnace 17 28...
Page 74: ......
Page 75: ......