Main Combi 25 Eco Elite User'S Manual And Important Warranty Information Download Page 9

6.0 Care of the Boiler

9

© Baxi Heating UK Ltd 2009

6.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. 

DO NOT USE ABRASIVE

CLEANING AGENTS.

6.2

Protection & Precaution

1. The boiler incorporates an integral frost protection feature

that will operate in both modes. If the boiler temperature falls

below 5° C, then the boiler will operate until the water

temperature has been raised.

2. If a system frost thermostat has been fitted (your installer

will be able to advise you), then to operate correctly and

protect your system, the gas and electricity must be left on and

the appliance set in the central heating mode.

3. The boiler incorporates an integral pump protection feature

which continually monitors the time since the pump last

operated. To prevent seizure, the pump will operate for

approximately 1 minute if it has not run in the last 24 hours.

6.3

Fault Indication

1. If a fault occurs on the boiler an error code may be shown

on the facia display (Fig. 9).

2. The codes are either two or three digit, preceded by the

letter 'E'. For example, code E133 will be displayed by 'E1'

alternating with '33'. E50 is shown as 'E' then '50'.

3. E20, E28, E50 & E160 indicate faulty components. You

should make a note of the displayed error code and contact

your installer or service engineer.

4. If E110 is displayed overheat of the primary water or flue

system has occurred. Turn the selector switch to the reset

position and hold for at least 5 seconds. If the boiler does not

relight, or the code is displayed regularly contact your installer

or service engineer.

5. E119 is displayed when the primary water pressure is less

than 0.5 bar. After repressurising the system the boiler should

operate. Your installer will be able to advise you about the

method of repressurising. See page 6 for further details. 

6. E133 indicates that the gas supply has been interrupted,

ignition has failed or the flame has not been detected. Ensure

that the gas supply has not been turned off, and turn the

selector switch to the reset position and hold for at least 5

seconds. If the boiler does not relight, or the code is displayed

regularly contact your installer or service engineer.

Central Heating NTC Fault

PCB Fault

Hot Water NTC Fault 

Safety Thermostat Operated

Water Pressure Switch Not Operated

Interruption Of Gas Supply or Flame Failure

Fan or Fan Wiring Fault

E20

E28

E50

E110

E119

E133

E160

Table of Error Codes

Reset

bar

0

1

2

3

4

Display

Then

Fig. 9

Summary of Contents for Combi 25 Eco Elite

Page 1: ...Baxi Heating UK Ltd 2009 User s Guide and Important Warranty Information Combi Eco Range Please keep these instructions in a safe place If you move house please hand them over to the next occupier...

Page 2: ...must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubl...

Page 3: ...ating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired an...

Page 4: ...on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN sec...

Page 5: ...itted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the...

Page 6: ...Fig 3 or on pipework near to the boiler 4 If you are unsure of its position or cannot identify it consult the installer who fitted the boiler 5 The filling loop consists of two taps and a separate fle...

Page 7: ...at 7 00 AM there is no hot water demand there will be no pre heat on Wednesday at this time 5 The feature also operates for one hour after each demand to maintain the temperature of the boiler 6 There...

Page 8: ...clearances for Safety and Maintenance Figs 7 8 Top 200mm 300mm for 80 125mm flueing system Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is ins...

Page 9: ...ng with 33 E50 is shown as E then 50 3 E20 E28 E50 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 is displa...

Page 10: ...or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Bodies 0086 For GB IE only 7 2 Benchmark Commissioning Checklist 1 Plea...

Page 11: ...used until the fault has been corrected by a competent person Warning Gas Tap Heating Flow Heating Return and Mains Water Inlet Isolating Valves Fig 10 In an Emergency If a water or gas leak occurs or...

Page 12: ...isit or for any general advice that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heatea...

Reviews: