![MAIMAN ELECTRONICS SF6060 Datasheet And User Manual Download Page 15](http://html1.mh-extra.com/html/maiman-electronics/sf6060/sf6060_datasheet-and-user-manual_3698169015.webp)
Maiman Electronics
SF6060
14
Available parameters and its description
Action
R/W
HEX-
number of
parameters
Frequency
(0.1 Hz)
Value
R/W
0100
Minimum
R
0101
Maximum
R
0102
Duration
(0.1 ms)
Value
R/W
0200
Minimum
R
0201
Maximum
R
0202
Current
(0.01 A)
Value
R/W
0300
Minimum
R
0301
Maximum
R
0302
Measured value (0.1A)
R
0307
Current set calibration
(0.01%)
2
Value
R/W
030E
Voltage (0.1 V)
Measured value
R
0407
State of the device
Start (Enable)
0008h
W
0700
Stop (Disable)
0010h
Internal current set
0020h
External current set
0040h
External Enable
0200h
Internal Enable
0400h
Allow Interlock
1000h
Deny Interlock
2000h
Deny NTC Interlock
4000h
Allow NTC Interlock
8000h
State of the device (bit
mask)
0 bit
1 – Device is powered on
(always = 1)
R
0700
1
st
bit
0 – Stopped; 1 – Started
2
nd
bit
Current set:
0 – External; 1 – Internal
4
th
bit
Enable:
0 – External; 1 – Internal
6
th
bit
External NTC Interlock:
0 – Allowed; 1 – Denied
7
th
bit
Interlock:
0 – Allowed; 1 – Denied
Serial number
Return the hex-value of the serial number
R
0701
2
Default – 100.00% (2710h), calibration range is from 95.00% (251Ch) to 105.00% (2904h).