background image

 INSTRUCTION MANUAL FOR DISHWASHERS

 

Page 6 of 12

 

 

UK 

 

 

3.4

 

Water circuit hookup 

The appliance must be connected to its water supply with a flexible hose. A 
shut  off  valve  (cock) must  be  installed  between  the  water  supply  line  and 
the appliance's solenoid valve. The cock must be close to the appliance. 

 

The water supply, temperature and pressure 

must be compatible

 with the ratings shown on the 

technical data plate on the machine.

 

 

Make sure that the water supply flow rate is no less than 20 l/min

 

 

If the water hardness is greater than 14 °f (8 °dH), we recommend using an internal water softener. 
If the water hardness is greater than 35 °f (19.5 °dH), install an  external water softener upline of 
the solenoid valve

 

  For machines without water softener: if the water hardness is greater than 14 °f (8 °dH), install an 

external water softener upline of the solenoid valve. 

  If the  water  has  a  very  high  residual  concentration  of  high  conductivity  minerals,  we  recommend 

installing a demineralisation system. 

  Machines  intended  for  use  with  desalinated  water  or  in  any  case  with  high  sodium  chloride 

concentration must be ordered specifically, as they require specific construction materials 

  Do not supply fully demineralised water to machines with a heat recovery unit with batteries with 

copper pipes. In this case, request the version with batteries with stainless steel pipes. 

 

 

 

Free drain 

3.5

 

Connection to the drain line 

 

  The drain line must  consist of a free drain sump with siphon suited to 

the  flow  capacity  of  the  drain  hose  supplied  with  the  appliance.  The 
hose  must  be  able  to  reach  the  sump  without  stretching,  restriction, 
folding, crushing, pressing or forcing in any way. 

  The tub drains under gravity, so the drain sump must be lower than the 

machine's base. 

 

Max. 

1 m 

 

 

With pump (available on request)

 

  if the drain is not lower than the base of the appliance, you can use the 

version with drain pump (available on request). 

  In this case, the drain connection may be no higher than 1 m. 

  Always check that the drain works properly and is not blocked. 

  Any other solution must be approved by the manufacturer in advance. 

3.6

 

Rinse aid and detergent 

  The  rinse  aid  and  detergent  are  dispensed  by  the  machine's  integral  dispenser  (depending  on 

model). 

  The dose is set by the installer in relation to the hardness of the water, and he also calibrates the 

dispensers themselves. 

 

Before calibrating them, fill the dispenser supply tubes with their respective product.

 

 

The units are calibrated with the adjuster screws, or directly with the control panel (as applicable).

 

  The level of fluid in the container must be sufficient for priming; do not allow it to drain completely 

or top it up with corrosive or impure product. 

NEVER use CHLORINE or HYPOCHLORITE based detergents. 

We recommend installing an automatic detergent dispenser. 

 
 
 
 

Summary of Contents for AMH50D

Page 1: ...ww caterparts com All spares available from Copyright Notice All rights reserved No parts of this manual may be reproduced in any form without express written permission of Maidaid Halcyon A trading n...

Page 2: ......

Page 3: ......

Page 4: ...OVING THE INTEGRAL FILTER 8 4 6 EMPTYING THE DISHWASHER 8 4 6 1 Appliances with no drain pump 8 4 6 2 Appliances with drain cycle optional 8 4 7 TURNING THE DISHWASHER OFF 8 4 8 RESIN REGENERATION OPT...

Page 5: ...or mental capacities or with no experience or knowledge provided they are supervised or after they have received training in the safe use of the appliance Children must not play with the appliance Cl...

Page 6: ...ional At the end of testing the installer must issue a written declaration stating that the machine has been installed and tested in accordance with established legislation and good practice DO NOT ch...

Page 7: ...e cover page of this manual The appliance may only be installed by qualified persons authorised to do so For Australia and New Zealand this machine must be installed in accordance with AS NZS3500 1 3...

Page 8: ...en the user s supply system and the public system The installer or appliance user is responsible for checking that the appliance is connected exclusively to a supply with system impedance Zsys less th...

Page 9: ...request the version with batteries with stainless steel pipes Free drain 3 5 Connection to the drain line The drain line must consist of a free drain sump with siphon suited to the flow capacity of th...

Page 10: ...ys wipe the dishes before placing in the dishwasher do not put dishes with dry or solid residues in the washer Place the empty dishes in the rack facing downwards Place plates and the like in the slop...

Page 11: ...xtract the tub filter and clean Fig 8 C 4 6 2 Appliances with drain cycle optional Switch the dishwasher off If present remove the integral filter Fig 7 A Withdraw the overflow if present by pulling i...

Page 12: ...enance and clean the machine as described in the section Maintenance If possible leave the door ajar to prevent bad odours building up inside the machine Chap 5 MAINTENANCE 5 1 General rules Before do...

Page 13: ...mechanical safety device The boiler or tub safety thermostats have cut in or the tub level safety pressure switch has been triggered Check that the drain is not blocked Switch the dishwasher off and t...

Page 14: ...l footprint if the following simple rules are observed Only wash full baskets Switch the dishwasher off when not using it Keep the machine closed when it is in standby Use wash programmes suited to th...

Page 15: ...INSTRUCTION MANUAL FOR DISHWASHERS Page 12 of 12 UK...

Reviews: