5. Operating the fan 

 

 Operating the fan 

ER EC fans run 

at 30 m³/h in base load 

operation

 (factory setting). 

A light switch or separate switch can be used 

to switch to 

full load operation with 60 m³/h

.  

The fan control and operating unit are located 

in the cover: ER-AK, ER-AH and ER-AB have 

automatic functions with unit parameters that 

can be set 

 chapter 11. 

 

ER-A

: Standard model 

 

ER-AK:

 Comfort model 

 

ER-AH: 

Model with humidity control, 

barrier-free 

 

ER-AB: 

Model with motion sensor, barrier-

free 

 

For full load operation, a 

start delay

 of  

60 seconds and an 

overrun time

 of  

15 minutes are specified 

at the factory

.  

 

 

The factory settings meet DIN 

18017-3. If the setting parameters in 

operation with cover ER-AK, ER-AH 

or ER-AB change, function in 

accordance with DIN 18017-3 is not 

always ensured. The planer/installer 

is responsible for operation in 

accordance with standards. 

 

 

In the event of overload (blocking), 

the fan switches off automatically.  

 

 

Ensure sufficient supply air during 

operation. 

 
 
 
 
 
 
 
 
 
 
 
 

 System and product 

information 

 

6.1 Certificates of approval  

 

Certificates of approval are available 

on request or on our website 

www.maico-ventilatoren.com. 

 

6.2 ER EC covers 

 

 

For ER EC cover components  

 Fig. 1. 

 

  All covers with exhaust air filter. Trouble-

free filter change without tools. 

  It is possible to rotate the cover by ± 5° to 

compensate for housings which have been 

fitted at an angle. 

  ER AH and ER-AB are barrier-free 

products. In automatic mode, they switch 

the fan automatically on and off. 

 

ER-A cover 

  Standard model 

  Air volume 30 m³/h, 60 m³/h 

  Filter change display via TimeStrip 

(

 title page). 

 

 

The 

TimeStrip

 for the ER-A 

standard cover is visibly attached to 

a location of your choice (e.g. next to 

the fan) after the filter change inter-

val has elapsed, it can be disposed 

of in the domestic waste. 

Do not 

affix the TimeStrip under the 

cover.

 New TimeStrips are included 

in the scope of delivery of the 

exchange air filter (

 accessories  

in chapter 16). 

Summary of Contents for ER-A

Page 1: ...Mounting and operating instructions ER EC covers For ER EC recess mounted exhaust air systems according to DIN 18017 3 ER A ER AK ER AH ER AB www m aico ventilatoren c om UK...

Page 2: ...2 1...

Page 3: ...nings 5 Operating the fan 7 System and product information 7 6 1 Certificates of approval 7 6 2 ER EC covers 7 6 3 ER EC functions 9 Environmental conditions and operating limits 10 7 1 Regulations fo...

Page 4: ...r part of cover central screw air filter these mounting and operating instructions For accessory components chapter 16 with more detailed information and order numbers Specialist installer qualificati...

Page 5: ...explosion Risk to health from chemicals or aggressive gases vapours Chemicals or aggressive gases vapours may harm health especially if they are distributed throughout the rooms by the fan Never use...

Page 6: ...nted Electric components are a potential source of electric shock If the unit is open all off the supply circuits must be switched off mains fuse off secured against being accidentally switched back o...

Page 7: ...In the event of overload blocking the fan switches off automatically Ensure sufficient supply air during operation System and product information 6 1 Certificates of approval Certificates of approval...

Page 8: ...r change display ER AH cover Model with humidity control and time module like ER AK Barrier free product In automatic mode the fans switch on when the humidity value limit is exceeded and switches off...

Page 9: ...base load and full load levels can be set Additional air volumes that can be set in base load 20 m h 40 m h and full load 100 m h Full load level on off via light switch or separate switch During manu...

Page 10: ...in residential units with air ventilated fireplaces if the evaluation criteria drawn up by the responsible regional master chimney sweep are met a parallel operation of air ventilated fireplaces for l...

Page 11: ...uction soiling if necessary 3 Check wiring diagram sticker for correctness of the ticked fan type 4 Check ease of movement of shutter When installed it must close automatically 5 Check that connection...

Page 12: ...of the housing in parallel The degree of protection according to the rating plate is only ensured in case of proper installation fan insert correctly engaged Installing the cover ER A ER AK ER AH ER...

Page 13: ...ime has expired the filter change LED blinks red every 5 sec To reset the filter change interval push the RESET button for 2 seconds As a confirmation the filter change LED flashes 1x briefly A new RE...

Page 14: ...have to be specified manually If the relative humidity falls below the reference value during operation the newly established reference value is saved The lowest possible reference value is 45 relativ...

Page 15: ...not use aggressive cleaning agents 1 Clean ER A cover only with a dry cloth 2 If the cover is very dirty remove it and clean with water 13 1 Filter change Change the air filter when ER A bar B is comp...

Page 16: ...lt Cause measure Fan output inadequate Dirty filter Replace filter Locking hook not engaged Engage fan insert correctly Incorrect duct diameter Check duct diameter of the main duct Supply air cross se...

Page 17: ...splay TimeStrip ZF EC replacement air filter for ER AK ER AH and ER AB article no 0093 0758 5x ZF EC replacement air filter filter class G2 Large pack of ZF EC replacement air filters for ER AK ER AH...

Page 18: ...18...

Page 19: ...19...

Page 20: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 info maico de D08 18_UK_DSW AS...

Reviews: