5. Operating the fan
7
Operating the fan
ER EC fans run
at 30 m³/h in base load
operation
(factory setting).
A light switch or separate switch can be used
to switch to
full load operation with 60 m³/h
.
The fan control and operating unit are located
in the cover: ER-AK, ER-AH and ER-AB have
automatic functions with unit parameters that
can be set
chapter 11.
●
ER-A
: Standard model
●
ER-AK:
Comfort model
●
ER-AH:
Model with humidity control,
barrier-free
●
ER-AB:
Model with motion sensor, barrier-
free
For full load operation, a
start delay
of
60 seconds and an
overrun time
of
15 minutes are specified
at the factory
.
The factory settings meet DIN
18017-3. If the setting parameters in
operation with cover ER-AK, ER-AH
or ER-AB change, function in
accordance with DIN 18017-3 is not
always ensured. The planer/installer
is responsible for operation in
accordance with standards.
In the event of overload (blocking),
the fan switches off automatically.
Ensure sufficient supply air during
operation.
System and product
information
6.1 Certificates of approval
Certificates of approval are available
on request or on our website
6.2 ER EC covers
For ER EC cover components
Fig. 1.
●
All covers with exhaust air filter. Trouble-
free filter change without tools.
●
It is possible to rotate the cover by ± 5° to
compensate for housings which have been
fitted at an angle.
●
ER AH and ER-AB are barrier-free
products. In automatic mode, they switch
the fan automatically on and off.
ER-A cover
●
Standard model
●
Air volume 30 m³/h, 60 m³/h
●
Filter change display via TimeStrip
(
title page).
The
TimeStrip
for the ER-A
standard cover is visibly attached to
a location of your choice (e.g. next to
the fan) after the filter change inter-
val has elapsed, it can be disposed
of in the domestic waste.
Do not
affix the TimeStrip under the
cover.
New TimeStrips are included
in the scope of delivery of the
exchange air filter (
accessories
in chapter 16).