Before the Digital Universal Caliper 25 ES is put into operation please read these instructions
carefully.

Safety points concerning the battery:

• not rechargeable
• do not incinerate
• dispose off as prescribed.

This instrument conforms to the EU-recommendations 89/336/EWG concerning
electromagnetic compatibility.

Important notes concerning first time use

The Digital Universal Caliper requires no extensive care. In order to ensure stable accuracy and
function the following should be observed:

• protect the Universal Caliper from dust, water or oil
• keep the beam clean and dry by periodically wiping over it with a dry, clean cloth
• when the data exit is not in use keep it closed, using the respective cover
• do not subject the caliper to any electric current (i.e. electric marker pen)
• unauthorized opening of the instrument forfeits the warranty.

Should you have any questions regarding the instrument, contact us and we shall be pleased to
answer them.

Technical Data

Measuring range

outside

0-300 mm (12")*

0-300 mm (12")

 0-600 mm (24"

0-1000 mm (40")

inside

25 -325 mm

25-325 mm

 25-625 mm

 25-1025 mm

Extended application range (reversing the measuring arms by 180°)

outside

up to 375 mm

up to 375 mm

up to 675 mm

up to 1075 mm

inside

up to 400 mm

up to 400 mm

up to 700 mm

up to 1100 mm

Beam cross section

24.5 x 5.6 mm

Resolution, switchable

0,01 mm (.0005")

Accuracy

DIN 862

Max. measuring speed

1,5 m/s (60"/s)

Measuring system

capacitive

Digital display

LCD, 6 digits and negative sign (-),

height of characters  6 mm

Battery

Lithium 3V, type CR2032, 190 mAh

service life approx. 2 years

Data exit

RS 232 C-compatible via interface

cable with opto-coupler

Operating temperature

+5  °C  to  +40 °C

Storage temperature

– 20 °C to  +70 °C

Max. relative humidity

80%

Weight (without measuring arms).750 g

770 g

970 g

1330 g

* caliper without fine adjustment

9

10

Description

1

Beam with measuring system

2

Right measuring arm holder, adjustable, with digital display and operating elements
2.1 Housing
2.2 LCD-display
2.3 Key for ON/OFF and HOLD
2.4 Selector key for measuring unit, reference, MAX/MIN and tolerance
2.5 Cover for battery compartment and data exit
2.6 Opening for RESET
2.7 Locking screw for clamping the measuring arm holder

3

Left measuring arm holder, adjustable
3.1 Locking screw for clamping the measuring arm holder in any position;
 allowing
perfect balancing of the measuring instrument for every measuring task.Particularly
advantageous when measuring small distances.

4

Fine adjusting device for adjusting to the required dimension (depending on type of
instrument)
4.1 Locking screw

5

Mounting grooves on upper and lower longitudinal edge of both measuring arm holders, each
with two threaded bores. In order to extend the application range , the exchangeable  Measuring
Arms 844 Te/Tx or Mounting Attachments 844 Tm can be reversed

Accessories

Measuring Arms 844 Te
Required with the following measuring anvils: 844 Tp, 844 Ts, 844 Tk, 844 Tr, 844 Tg.

Measuring Arms 844 Tx
Required with the following measuring anvils: 901 to 908, 911 H, 912, 913.

Mounting Attachments 844 Tm
Required with the following measuring anvils: 844 Ti, 844 Ta, 844 Tv, 844 Tz, 844 Tt, 844 Tu, 844 Tb,
844 Tc, 25 Eb, 25 Es, 25 Eh.

Introduction

The Digital Universal Caliper 25 ES is used for measuring of outside and inside measurements,
external and internal threads, hole centre distances, registers, narrow collars, grooves, dovetails,
outside and inside tapers, external and internal tapers. Patented mounting of measuring arms resp.
mounting attachments is provided on the upper or lower longitudinal edge of both measuring arm
holders. The application range for internal and external measurements can be extended by 75 mm by
reversing the measuring arms. Virtually all measuring tasks can be solved on account of the various
operating functions of the instrument and of the wide range of accessories.

USA

Summary of Contents for 25 ES

Page 1: ...hl 6 Bedienung 7 Messbeispiele 7 Abbildungen 24 Table of Contents Page Designation 1 Description 9 Accessories 9 Introduction 9 Important notes concerning first time use 10 Technicaldata 10 Setting an...

Page 2: ...lbaren Messarme 844 Te Tx oder Aufnahmest cke 844 Tm umdrehbar Zubeh r Messarme 844 Te Erforderlich bei folgenden Messeins tzen 844 Tp 844 Ts 844 Tk 844 Tr 844 Tg Messarme 844 Tx Erforderlich bei folg...

Page 3: ...bers 25 ES empfehlen wir Ihnen diese Bedienungsanleitungaufmerksamundvollst ndigzulesen SicherheitshinweisezurBatterie nichtwiederaufladbar nicht ins Feuer werfen bittevorschriftsgem entsorgen Dieses...

Page 4: ...der Z hlrichtung Taste 2 3 und 2 4 gleichzeitig l nger als 2 Sek gedr ckt halten Die Anzeige wechselt st ndig zwischen 0000 01 und 0000 01 in der PRESET Eingabefunktion nicht m glich Sobald der Ziffer...

Page 5: ...n m glich 844 Tp 844 Ts 844 Tk 844 Tr nur Flanken 844 Tc 901 bis 908 911 H 912 913 2 Vorbereitung f r die Messung des Istma es mittels Einstellnormal z B Einstellehre 25 Eel Parallelendma oderEinstell...

Page 6: ...ription 1 Beam with measuring system 2 Right measuring arm holder adjustable with digital display and operating elements 2 1Housing 2 2LCD display 2 3 Key for ON OFF and HOLD 2 4 Selector key for meas...

Page 7: ...function press key 2 4 for more than 2 sec 12 Note The instrument cannot be switched off while the PRESET input function is active MIN MAX function Automatic storage and display of MIN and or MAX as...

Page 8: ...Tz 3 Measuringofdeviations comparativemeasurements 3 1 Mount suited measuring arms with measuring anvils in one of the mounting grooves of both measuring arm holders 3 2 Set display to nominal value u...

Page 9: ...errage pour maintenir le guide dans la position voulue 3 Guide gauche mobile 3 1 Vis de serrage pour maintenir le guide dans la position voulue permet pour chaque t che de mesure un quilibrage optimal...

Page 10: ...marche appuyer bri vement sur la touche 2 3 ON OFF Nota La derni re fonction activ e avant la mise hors circuit de l appareil appara t sur l affichage Mise hors circuit appuyer plus de 2 sec sur la t...

Page 11: ...ches 2 3 et 2 4 L affichage change constamment entre 0000 01 et 0000 01 impossible dans la fonction d introduction PRESET D s que la r solution est affich e avec le signe souhait rel cher les deux tou...

Page 12: ...de mesure en position dans l une des rainures des deux guides 3 2 Ajuster la cote th orique au moyen de l talon de r glage ou du normal proc der comme indiqu sous 2 2 2 4 3 3 Remettre z ro l affichage...

Page 13: ...F G H A B C D E TOL SET TOL MM SET INCH SET INCH SET REF I MM SET PRESET REF I SET MIN REF I HOLD B MM SET I Abbildungen Bitteausklappen Illustrations Please fold out Illustrations Ouvrir le volet 24...

Page 14: ...Notizen Notes Notes 23...

Reviews: