Mahlkonig Guatemala K22S) Operating Instructions Manual Download Page 13

|

L A D E N M Ü H L E N

S H O P   G R I N D E R

13. Warranty Conditions

1. 

The warranty period is 1 year from the date of purchase.

2.  The warranty covers all damages that can be attributed to inferior 

materials or defective workmanship. Corresponding grinders will be 
repaired or replaced free-of-charge, with the exception of transport 
or freight charges. Transport is the responsibility of the customer. 
Therefore, avoid damages with all returns by correct packing.

3.  The grinder may only be opened for cleaning purposes in accor-

dance with the Operating Instructions.

4.  This warranty does not cover damages which have occurred 

through: Improper usage, improper maintenance, lack of servicing, 
usage for purposes other than those intended, incorrect installa-
tion, incorrect voltage, breakage, natural wear or for reasons be-
yond our sphere of influence.

5.  In order to maintain the warranty, only original spare parts and ac-

cessory parts may be used.

6. 

Observe in addition our General Delivery Conditions in their respec-
tive current version.

7.  The manufacturer is in no way liable for consecutive or secondary 

damages.

8.  The warranty does not cover costs emerging from repairs conduct-

ed by non-authorized personnel.

page 13

12. Certificate

EC Declaration of Conformity

The manufacturer:  

MAHLKÖNIG GmbH & Co. KG

    Tilsiter 

Straße 

142

    D 

22047 

Hamburg

 

 

 

 

Tel.: +49 (0) 40 69 69 40 - 0

 

 

 

 

Fax: +49 (0) 40 69 39 72 - 1

hereby declares that the below mentioned product:

product type: 

 

device for food processing

machine description: 

 Coffee 

grinder

machine typ: 

 K32S: 

Guatemala 

is in compliance with the following directives and regulations:
 
• 

The provisions of the Machinery Directive  

 

 

 

2006/42/EG

• The 

Low 

Voltage 

Directive 

      73/23/EWG 

• 

The EC Electromagnetic Compatibility Directive 

 

 

2004/108/EG

• 

The Directive on the restriction of use of certain

 

hazardous substances in electrical and electronic equipment 

2011/65/EU

• 

The EU chemicals regulation (REACH – Regulation)   

 

(EG) Nr. 1907/2006

Supplements in Europe:

Regulation 

1935/2004 

    Requirements 

for 

materials 

and

        the 

objects 

with 

Food 

comes 

into

 

 

 

 

 

 

 

 

contact 

Documentation 

Agent: 

    Sven 

Erdmann

Address of the proxy documentation:   

 

See the address of the manufacturer

Done in Hamburg on:  

 

 

 

 

01.08.2013

Function of subscriber:    

 

 

 

General Manager

Name 

of 

signatory: 

     Philipp 

Baumberger

Signature

MAHLKÖNIG GmbH & Co. KG, Amtsgericht Hamburg HR A 85 074; Persönlich haftende Gesellschafterin:

Beteiligungsgesellschaft MAHLKÖNIG mbH, Eingetragen Amtsgericht Hamburg HR B 45 324, 

Geschäftsführer: Nils Erichsen, Philipp Baumberger, Jochen Christoph

Dresdner Bank AG (BLZ 200 800 00) Kto. 383 780 400, Postbank Hamburg (BLZ 200 100 20) Kto. 253 89-203, 

C

b

k AG (BLZ

) Kt

U t Id N DE 8

6

Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL (866) 244-1578 www.coffeelabequipment.com

Summary of Contents for Guatemala K22S)

Page 1: ...H O P G R I N D E R The professional art of grinding since 1924 Operating Instructions Guatemala K32S K22S the casual one Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Page 2: ... L A D E N M Ü H L E N S H O P G R I N D E R Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Page 3: ...tallation 7 5 3 Initial operation 7 6 Operation 8 page 3 7 Operating Faults 8 8 Recalibration of the Grind Adjustment 10 9 Cleaning 10 9 1 Cleaning with GRINDZ Grinder Cleaner 11 9 2 Cleaning of the Grinder Casing 11 9 3 Cleaning of the Grinding Mechanism 11 10 Maintenance and Repair 12 11 Spare Parts 12 12 Certificate 13 13 Warranty Conditions 13 14 Wiring Diagram 14 Coffee Laboratory 589 Rappahan...

Page 4: ...out proper supervision Never immerse the grinder in water and do not oper ate it with wet hands page 4 1 Safety Please read and observe the following operating in structions carefully Non observance can result in damage to the grinder as well as in health threaten ing risks for the user 1 1 Symbols The following two symbols are used in this manual of operating instruc tions Safety instruction In c...

Page 5: ...nscious basis is also expected 2 Technical Data Description Guatemala K32S K22S Voltage Frequency 220 240V 50 60Hz 115V 60Hz 100V 50 60Hz Rotation 50 Hz 2850 rpm 60 Hz 3400 rpm Sound emission idle operation 65 dB operation 85 dB Pre fuse 16 A slow Overload circuit breaker 230V 50Hz 7A T 220V 60Hz 8A T 115V 60Hz 16A T incl in switch 100V 50Hz 10A T 100V 60Hz 16A T incl in switch max operating time ...

Page 6: ... with lid Pos 2 Grind adjustment Pos 3 Spout Pos 4 Bag holder Pos 5 Tray for residues Pos 6 On Off Switch Pos 7 Reset button for current overload back Pos 8 Bag holder handle Pos 9 Casing with motor and grinding mechanism 1 2 3 4 5 8 9 7 6 Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Page 7: ...ic circuit of the motor when the device is sub jected to electric overloading To be able to re start the grinder the reset button on the back side of the casing must be pressed Pos 7 The user has no influence whatsoever on this opera tion In case of repeated tripping of the circuit break er an expert must be consulted since this could cause damage to the motor winding Motor protector winding shield...

Page 8: ...on 1 By moving the rotary knob set the required grind degree to the left for coarse coffee powder to the right for finer coffee powder 2 Only fill unground materials for which the grinder is set up for into the hopper Close the hopper 3 Press down the handle of the bag holder pos 8 and push the com pletely opened bag which has been smoothed along the folds over the spout pos 3 Let go of the handle a...

Page 9: ...out let Check to determine wheth er the reset button of the circuit breaker has jumped out Press the reset button in again if appropriate In case of repeated tripping of the circuit breaker contact your authorised customer service centre or dealer Give the grinder a cooling off break of at least 100 minutes para 4 Check the pre fuse Restore the pre fuse to its initial state or replace it Deter min...

Page 10: ...ign objects fall into the grinding mechanism Adjusting spindle 8 Recalibration of the Grind Adjustment The grinder has been precisely adjusted by the manufacturer However if the ground material is no longer fine enough after a longer period the grinder must then be re adjusted according to the following procedure 1 Use a screwdriver to unscrew the fastening screw in the middle of the rotary knob an...

Page 11: ...he grinding mechanism Pull out the power supply plug 1 Rotate the rotary knob 11 to coarse 2 Unscrew the two screws 13 on the grinder casing cover 12 and then remove this cover 3 Take the carrier 10 out of the slot of the pre breaker 4 Pull the pre breaker 9 off the motor shaft Use a special puller art no 4041 5 Clean the grinding mechanism with a fine brush and remove any foreign objects 6 Before ...

Page 12: ... by authorised experts Please contact an authorised customer service centre or your local dealer 10 1 Grinding Disc Replacement If the grind capacity decreases and the ground coffee is hot and of irregu lar grind size you should change the grinding discs 1 Take the grinder apart as described in para 9 3 and remove the grinding discs from the grinder casing and the pre breaker using a screwdriver 2...

Page 13: ...rer MAHLKÖNIG GmbH Co KG Tilsiter Straße 142 D 22047 Hamburg Tel 49 0 40 69 69 40 0 Fax 49 0 40 69 39 72 1 hereby declares that the below mentioned product product type device for food processing machine description Coffee grinder machine typ K32S Guatemala is in compliance with the following directives and regulations The provisions of the Machinery Directive 2006 42 EG The Low Voltage Directive ...

Page 14: ...7k K1 Motor Start Relay Klixon 2CR3 207 F1 Current Overload Switch ETA 2 5700IG1 P10 1050 7A S1 Switch ETA 3120 F30F G701 SGRX 20A M1 Motor Elnor 270 CII 230V 50Hz X1 Mains plug X2 Blade Terminal 6 3mm 14 Wiring Diagram Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Page 15: ... L A D E N M Ü H L E N S H O P G R I N D E R Notes Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Page 16: ...G GmbH Co KG Tilsiter Straße 142 D 22047 Hamburg Germany Tel 49 0 40 69 69 40 0 Fax 49 0 40 69 39 721 office mahlkoenig de www mahlkoenig de March 2014 Subject to be changed without prior notice Coffee Laboratory 589 Rappahannock Drive White Stone Va 22578 TEL 866 244 1578 www coffeelabequipment com ...

Reviews: