2.  Selection and function keys

Keys

Name

Function

O

OK

Confirm and store

Function depends on current menu

Back
Cancel

Back one menu level or cancel

 

or

 

Up or down control

 

or

 

Right or left control

Enter

Confirm and store

C

Delete

Deletes character to left of cursor

i

Information

Show current data

Switching between number and 
letter input. Current mode is shown
at bottom right of screen.

3.  Refrigerant identification unit

 

D

Before connecting service hoses proceed as follows:

1. 

Verify that the oil system type matches between the actual 
vehicle A/C system and current configuration of the ACS 
unit (PAG or POE). If required change oil type in “

Settings

 

>> 

A/C Service Parameter

” (see operating instructions 

chapter 4.4).

2. 

Perform refrigerant identification (see operating instructions 
chapter 6.3).

 

D

Use of a refrigerant identifier reduces the risk of contamina-
tion of ArcticPro 200yf. If the service hoses are connected to 
the vehicle before refrigerant identification there is the risk for 
contamination the refrigerant system of ArcticPro 200yf.

 

M

The contamination in the ArcticPro 200yf can only be removed 
by a service provider at additional cost.

 

D

The type of oil (PAG or POE) is always to be checked prior to 
A/C service and altered to suit the type of vehicle.

3.1 

Refrigerant analysis

 

M

Before first operation with refrigerant identifier please read 
chapter 3.4 in Original instructions of ArcticPro 200yf.

1. 

Switch on the ArcticPro 200yf.

2. 

Select vehicle A/C service.

3. 

Switch on the refrigerant identification unit.

4. 

Follow the menu prompting of ArcticPro 200yf.

 

M

Getting message “

 Sample not OK 

”, check for contamina-

tion of the test hose, then repeat the procedure up to 2 times. 

 

M

Getting message “

 Sample not OK 

” for three times, a  

refrigerant verification must be performed.

3.2 

Refrigerant verification

 

M

Connect refrigerant identification unit to an external R1234yf 
bottle with 100 % R1234yf.

1. 

Connect refrigerant identification unit to the power supply.

2. 

Switch on the refrigerant identification unit.

 

M

Do not connect USB connecting cable with ArcticPro 200yf.

3. 

Follow the menu prompting of refrigerant identification unit.

 

M

Contact customer service after not passed analysis for 3 times.