10.7 Vacuum pump  oil change

 

  

After 60 hours of runtime (or 1000 hours if the Long 

Life  Pump test is completed successfully), the 
vacuum pump oil  must be replaced.

 

 

1.  Disconnect ACX2281 from power. 
2.  Using a flathead screwdriver, rotate the front locking 

screw and lift the front housing. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 29: Changing vacuum pump oil

 

Oil filling plug

 

Oil inspection window

 

Lower drain plug

 

 

3.  Place a bowl under the vacuum pump oil drain hole.  

Remove the upper filling plug and the lower drain plug to 
allow the oil to drain from unit. 

4.  Once the pump has been emptied, reinstall  the  lower 

drain plug. 

5.  Fill the pump with new oil through the upper fill port using 

a funnel if needed.  Fill until the oil appears halfway up the 
oil level inspection window. 

6.  Once  the pump  has been filled, reinstall the upper fill 

plug.

 

7.  Close front housing and secure locking screw.

 

8.  Connect to power and turn on.

 

9.  From the  MAINTENANCE  menu, press 

 

until 

PUMP  OIL  REPLACEMENT is highlighted and press 
arrow.  Press the RESET key to set the counter. The level 
and clearness of the vacuum pump oil can be checked by 
removing the rubber plug located on the front-left side of 
the unit. 

 

10.8 Replace filter dryer

 

 

 

Unit operation is disabled at the end of the filter service life. 
Each filter is marked with a unique code. This code must be 
entered when replacing the filter. It is not possible to operate the 
ACX2281 if the same code is re-used. It is advisable to keep a 
supply of filters in stock to avoid downtimes due to the unit being 
disabled. 

 

The ACX2281 is disabled once 90kg (198lb) of R1234yf 
refrigerant has passed through the filter. A new filter must be 
installed and its unique code entered in the ACX2281 before 
vehicle A/C service can be performed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 30: Changing filter dryer

 

Filter dryer

 

 

1.  To begin the filter replacement process, from the MAINTENANCE 

menu,  scroll until  FILTER  REPLACEMENT  is highlighted and press 
arrow.

 

2.  Insert the new filter code using the keypad.

 

3.  Using a flathead screwdriver, rotate the front locking screw and lift the 

front housing. 

4.  Verify that the 2 o-rings are included and positioned correctly prior to 

attaching to housing. 

5.  Loosen the filter using a 1-3/8” 

(35mm) wrench. 

6.  Remove the filter 
7.  Insert a new filter 
8.  Tighten the filter to 74 ft-lbs (100N-m) 
9.  Carefully close front housing and 

secure locking screw. 

10. Allow unit to perform the automatic 

leak test requested by the software 
when unit loads

Warning - Risk of frostbite from escaping 
refrigerant

 

Refrigerant causes severe frostbite on the 
skin.

 

Check the service hoses for damage.

 

 

Firmly connect the service quick-release 

couplings to the service hoses.

 

 

Wear protective goggles.

 

 

Wear protective gloves.

 

Summary of Contents for ACX2281

Page 1: ...MAHLE ACX2281 EN Operation Manual A C Service Equipment...

Page 2: ...en 2 ACX2281...

Page 3: ...e of connection of external refrigerant bottle 17 7 5 Internal Bottle Fill 17 8 A C service preparation 18 8 1 Preliminary preparation 18 8 2 Non condensable gas discharge 18 8 3 Charge Modes 18 8 3 1...

Page 4: ...led and instructed personnel only Personnel scheduled to be trained familiarized and instructed or to take part in a general training course may only work with the product under the supervision of an...

Page 5: ...towards the prevention of accidents industrial diseases labor related health risks are taken and measures towards making the workplace fit for people to workinarecarriedout Basic rules The contractor...

Page 6: ...If the refrigerant has been contaminated by being mixed with other gases remove the contaminated refrigerant and add fresh R1234yf before using the ACX2281 for A C service R1234yf is not to be used in...

Page 7: ...r safety reasons it is advisable to use a residual current operated circuit breaker rccb with the following specifications Parameters Rated voltage 110 VAC 10 Rated frequency 50 60Hz Rated current 10A...

Page 8: ...antity 250ml Compressor capacity 0 87cu in 14cc Dryer filter 90kg recovered R1234yf Non condensable gas purge Automatic via solenoid valve HP and LP taps Automatic Display 7 inch capacitive touch scre...

Page 9: ...an only be operated with R1234yf The ACX2281is not to be used for service work on vehicles with air conditioning systems employing refrigerants other than R1234yf as this will cause damage Prior to A...

Page 10: ...er 5 Power Cord socket 4 Description of unit Fig 3 Front Left view 1 Vacuum pump oil level sight glass Fig 2 Rear View 1 Service Hoses 2 Fan 3 Vent 4 Hose Storage Fig 1 Front Right View 1 Rear Handle...

Page 11: ...Description of unit ACX2281 11 en Fig 4 Internal components 1 Accumulator Oil separator 2 Combo filter 3 Compressor 4 Vacuum pump 5 Refrigerant tank 6 HS compressor oil separator 7 Manifold...

Page 12: ...e used to monitor the pressure during the individual vehicle A C service phases The status of the various service phases during maintenance is displayed on the LCD screen Fig 5 Pos 2 The status and wa...

Page 13: ...the cylinder Avoid the refrigerant loss dispersion in the air during the disconnection of the couplers Puff effect CheckpossibleSchradervalveleaksbefore disconnection Fig 8 EcoLOCK Couplers To connect...

Page 14: ...to generate a vacuum in the air conditioning system which removes excess moisture and to detect possible leaks in the vehicle air conditioning system Used oil is separated from the recovered vehicle...

Page 15: ...erations described in this manual Remove staples and remove the carton Fig 10 Slowly lower the unit from pallet by means of the rear wheels Fig 12 Fig 12 Lowering unit from the pallet Keep the pallet...

Page 16: ...ations 7 2 First start up verification Warning Risk of frostbite from escaping refrigerant Refrigerant causes frostbite on the skin Check the service hoses for damage Firmly connect the service quick...

Page 17: ...stbite on the skin Check the service hoses for damage Firmly connect the service quick release couplings to the service hoses Wear protective goggles Wear protective gloves Before the ACX2281 can be u...

Page 18: ...stalled in vehicle A C system Lubricant removed from the system and or equipment shall be disposed of in accordance with the applicable federal state and local procedure and regulations The service pa...

Page 19: ...failed identifications 2 Switch off the ACX2281 unit 3 Disconnect power cord from outlet 4 Move unit outside 5 Connect High and Low side couplers to the Parking Flush adapter and open valves to equal...

Page 20: ...ess the green arrow in the lower right corner of the screen Fig 17 Automatic setting confirmation 6 If settings are correct press START button to begin process 9 3 Manual cycle setup Access to manual...

Page 21: ...n in Figure below will appear Fig 19 Vacuum time adjustment 4 Swipe finger up or down to adjust the hours and minutes then press the to accept or the X to cancel time adjustment 5 If the vacuum test t...

Page 22: ...e menu prompting to complete oil flushing 9 8 Vehicle Pressure Check 1 From the MENU scroll to SPECIAL FUNCTIONS and select The SPECIAL FUNCTIONS screen will now be displayed Fig 23 Vehicle pressure c...

Page 23: ...tion fittings To ensure a reliable procedure it is advisable to use the optimum quantity of refrigerant The optimum quantity of refrigerant for the ACX2281is 4kg 10 0kg An inadequate quantity of refri...

Page 24: ...and the filter dryer need replacement 1 From the MAINTENANCE menu scroll until MAINTENANCE COUNTERS is shown and make selection 2 Press to display all counters Fig 28 Maintenance counters 10 6 Long li...

Page 25: ...ervice life Each filter is marked with a unique code This code must be entered when replacing the filter It is not possible to operate the ACX2281 if the same code is re used It is advisable to keep a...

Page 26: ...locking screw and lift the front housing 7 Once the unit is open inspect the clear hose coming from the back of the identifier down to the manifold assembly 8 Replace sample clear hose if oil is pres...

Page 27: ...acuum pump oil 011 80070 00 Paper for printer 5 rolls 360 83110 00 Service hose HP 360 82948 00 Service hose LP 360 82949 00 Quick release coupling HP 360 82950 00 Quick release coupling LP 360 82951...

Page 28: ...Maintenance ACX2281 28 en 12Maintenance 12 1 Vacuum pump oil change Vacuum pump oil change record Date Maintenance technician identification Maintenance technician signature and stamp...

Page 29: ...en 29 ACX2281 Maintenance Vacuum pump oil change record Date Maintenance technician identification Maintenance technician signature and stamp...

Page 30: ...Maintenance ACX2281 30 en 12 2 Filter dryer change Filter Dryer Change Record Date Maintenance technician identification Maint Tech signature and stamp...

Page 31: ...en 31 ACX2281 Maintenance Filter Dryer Change Record Date Maintenance technician identification Maint Tech signature and stamp...

Page 32: ...Maintenance ACX2281 32 en Filter Dryer Change Record Date Maintenance technician identification Maint Tech signature and stamp...

Page 33: ...aintenance 12 3 Refrigerant load cell calibration check Refrigerant Load Cell Calibration Check Record Date Result of check pass fail Maintenance technician identification Maintenance technician signa...

Page 34: ...nance ACX2281 34 en 12 4 Other checks maintenance repairs Other checks maintenance repairs Job Date Result of check pass fail Maintenance technician identification Maintenance Technician signature and...

Page 35: ...en 35 ACX2281 Maintenance 12 5 Notes...

Page 36: ...MAHLE Aftermarket Inc Service Solutions 23030 MAHLE Drive Farmington Hills MI 48335 USA 717 840 0678 www servicesolutions mahle com 035 82693 01 REV A 2021 10 18...

Reviews: