Maintenance Manual
MAN-00
167
XYLO
mHawk
February 2012/ Rev1
The repair methods given by the manufacturer in this document are based on the technical specifications
,
current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of
or
whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra
Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
712-MAT-0032 : 0.10 hrs
BATTERY ELECTROLYTE LEVEL - CHECK
Refer above illustration –
1.
Ensure the electrolyte level between MIN and MAX marks (if the electrolyte level is less than
the MIN mark, then top up the electrolyte to the recommended level with distilled water.
2.
Check the terminals clamps for clean and tightness; if required clean it and fix it tightly.
3.
Check the other end of battery cables for tightness.
Battery Electrolyte Level Check
Battery rating: 12V, 65Ah.
Toping up should be done with distilled water only.
Never use normal water or mineral water to top battery electrolyte.
Vent holes should be clear.
Clean the terminals.
Use petroleum jelly in case of terminals gets rusty.
Tighten the terminals along with cable fitments properly.
Battery Electrolyte Level Check to be inspected at every 10000kms.
Page 45