34
Manifold & Cylinder Head
Tappet Setting
15.
Tighten the nut by keeping filler gauge in insert position.
16.
Insert filler gauge of 0.50 mm for Exhaust valve
17.
Loose nut, tighten grub screw & insert filler gauge.
Note: - Filler gauge movement should not be more tight or loose.
18.
Tighten the nut by keeping filler gauge in insert position
19.
Rotate flywheel anti-clockwise.
20.
Press 3
rd
cylinder exhaust valve.
21.
Do tappet setting of 2
nd
cylinder.
22.
Insert filler gauge of 0.40 mm for Inlet valve
23.
Loose nut, tighten grub screw & insert filler gauge.
Note: - Filler gauge movement should not be more tight or loose.
24.
Tighten the nut by keeping filler gauge in insert position.
25.
Insert filler gauge of 0.50 mm for Exhaust valve
26.
Loose nut, tighten grub screw & insert filler gauge.
Note: - Filler gauge movement should not be more tight or loose.
27.
Tighten the nut by keeping filler gauge in insert position.