![MAHA Powerdyno MSR 400 Original Operating Instructions Download Page 66](http://html1.mh-extra.com/html/maha/powerdyno-msr-400/powerdyno-msr-400_original-operating-instructions_3658233066.webp)
66
BA053401-en
9.2
Measure Engine Power
The vehicle’s engine power is measured using this menu point. After selecting this menu point the
following selection appears. Select the individual menu points using the cursor keys or the mouse.
The menu points are explained below.
Continuous measurement
Discrete measurement
Display last measurement
9.2.1
Display Last Measurement
If the last conducted measurement is not stored and the measurement menu exited, use the item
"Display last measurement" to view the measurement again. When exiting the LPS program the
temporary storage (or the last measurement conducted) is deleted.
Only active with continuous and discrete measurements!
9.2.2
Continuous Measurement
The max. power is determined during a continous measurement and the engine power is
calculated according to DIN 70020, EWG 80/1269, ISO 1585, SAE J1349 or JIS D1001 ECE, DIN,
EWG or ISO (Optional), depending on which setting has been selected in category "Power
Correction”. The curves for wheel, drag and engine performance are displayed graphically. If air
pressure and temperature have been taken into consideration (measured) the engine performance
is displayed as standard performance.
1 Position the vehicle on the dyno and fix it.
2 Open menu MEASURE ENGINE POWER and then menu item CONTINUOUS MEASUREMENT.
The following screen appears: