If 

REFRESH & ANALYZE

 mode is selected: 

 
The charger will prompt for the charging rate by flashing “

SET CHG 

RATE

.” Use the 

UP

 and 

DOWN

 key to choose the desired current. 

Press 

ENTER

 to make the selection.  

 

 

 
Then it will prompt from the discharging rate by flashing 

“SET 

DISCHG RATE

.” Follow the same procedure as above.  

 

 

 
 
 
If 

BREAK-IN

 mode is selected:  

 
The charger will prompt for the battery capacity in order to calculate 
the charging and discharging rate automatically. 

“SET BATTERY 

CAPACITY

” will flash. Use the 

UP

 and 

DOWN

 key to choose the 

desired current. Press 

ENTER

 to make the selection.  

 

 

 
 
 

If 

DISCHARGE

 mode is selected: 

 
The charger will prompt for the discharging rate by flashing 

“SET 

DISCHG RATE

.” Use the 

UP

 and 

DOWN

 key to choose the desired 

current. Press 

ENTER

 to make the selection.  

 

 

 
 
 
If 

CYCLE

 mode is selected:  

 
The charger will prompt for the charging rate and discharging rate 
similar to the other modes. In addition, it will also prompt for the 
number of cycles to be performed by flashing 

“SET CYCLES

.” Use 

the UP and 

DOWN

 keys to choose the desired cycles. Press 

ENTER

 to make the selection.  

 

 

 

 

 
 
 
6. 

To ensure safety, the charger performs an “impedance check” at the 
beginning of the program. If the battery fails this test, “HIGH” would 
be displayed and program will be terminated.  

 

 

 
 

Typically alkaline and extremely aged battery will fail this test. For a 
rechargeable battery, it is recommended for the battery to be 
discarded.  
 
NOTE: This test is not performed for the discharge mode.  
 
If this detection is believed to be incorrect, a discharge can be 
performed first.  

 
 
7. 

While executing the programmed function, the charger will display 
the battery status for each occupied slot consecutively. The screen 
will first show an arrow below the active bank and display the 
information. The next slot(s) occupied follows.  

 

Press the 

SLOT

 button at anytime will jump to the next occupied 

slot. Press this button multiple times if necessary to go to the desired 
slot.  
 
The following information is displayed on the screen:  
 

Current

:  

 
This is the number followed by the unit “

MA

.” This is the 

approximate charging or discharging current. Note that this number 
will go up and down due to the pulse charging.  
 

 

 

 

Capacity

:  

 
This is the number followed by the unit “

MAH

.” This is the 

accumulated charging or discharging capacity. If it is charging 
capacity, “CHARGE” in black box will be shown. If it is discharging 
capacity, “DISCHG” in black box will be shown.  