Communications Setup
ULTRA-600 communications enabled software communication over Ethernet using the MLAN Protocol.
For more information about the MLAN Protocol and the ULTRA-600 Dryer see the MLAN Protocol
manual, available on the Maguire Products Inc website.
MLAN communications over Ethernet use port 9999 to communicate.
Modbus communications, when enabled (see below), use port 502.
Setting the MLAN ID Number
Press
Display will prompt for a password.
(default: 22222)
Then press:
Press
Display will show the System Configuration categories.
Press
Communications
Display will show the System Communications
categories.
Press
MLAN I.D. Number
Display will show the MLAN I.D. Number screen.
On this screen, enter the new ID number using the
keypad. Valid I.D. numbers are 1 though 254.
Press
To save the Changes.
Setting the IP Address, Subnet Mask, Gateway
Press
Display will prompt for a password.
(default: 22222)
Then press:
Press
Display will show the System Configuration categories.
Press
Communications
Display will show the System Communications categories.
Press
TCP/IP
Configuration
Display will show the TCP/IP Configuration screen. On this
screen, enter the IP Address, Subnet Mask and Default
Gateway. Use the keypad to enter the number into the field
highlighted in green. To advance to the next field, touch
the field you want to edit and type the desired value.
Press
To save the Changes.