2.1.2 SUPPORTED INSTALLATION
The measuring shaft is supported by the torque sensor housing, which itself is fixed to the test bench frame
by means of a support unit (
). Here, couplings with two degrees of freedom must be used in or-
der to avoid hyperstatic mountings.
Fig.2-2 Supported Installation
2.1.2.1 ADVANTAGES
▪
Increased critical speed due to less shaft bending.
2.1.2.2 DISADVANTAGES
▪
Longer overall length of the test bench due to the use of double-element couplings.
▪
Increased price due to the higher price of double-element couplings.
Supported installations are required when larger misalignments between the different ele-
ments of the system are a possibility, as well as with high rotational speeds.
High-performance couplings can be realized by mounting flanges directly onto a splined torque trans-
ducer shaft. (Not available on all models.)
2.1.3 TM / TMB IN VERTICAL INSTALLATION
Fig.2-3 Vertical installation
SEE SECTION 2.2 - PARASITIC FORCES
OF THIS MANUALS TO UNDERSTAND THE MAX-
IMUM ACCEPTABLE F
A
FORCE!.
NOTICE
F
R
F
A
F
A
F
R
F
R
F
R
CORRECT
WRONG
CAUTION
14
TM
series
INSTALLATION / CONFIGURATION
Summary of Contents for TM Series