24
Magtrol Hysteresis Dynamometers
Chapter 3 – Installation/Configuration
SETUP
3.3.3.1
Blower Setup
If an hD-710, hD-715, hD-810, hD-815, ED-715 or ED-815 dynamometer is being used, a blower
input is integrated into the unit.
Figure 3–10 Dynamometer with Blower Connection
For more information, see
Section 4.1.3.2.2 – Blower
.
WARNING! due To The NoIse levels of The bloWeRs,
heARING pRoTecTIoN musT be WoRN duRING
opeRATIoN.
3.3.3.2
Compressed Air Setup
If a Model 510, 515, 800 or 805 dynamometer is being used, a compressed air input is integrated
into the unit. The connection is illustrated in the following diagram.
1,5
psi
1,0
0,5
0
o
2,0
2,5
3,0
Figure 3–11 Dynamometer with Compressed Air Connection
For more information, see
Section 4.1.3.2.1 – Compressed Air
.