Appendix E - EMV Factory Defaults (EMV Only)
eDynamo| Secure Card Reader Authenticator | Programmer’s Manual (COMMANDS)
Page 229 of 245 (
D998200115-17
)
E.2.2
EMV Contact Application Settings and Defaults (Contact Only)
This section lists the default EMV Contact Application Settings. For information about reading and
changing these settings, see section
8.5.4 Extended Command 0x0308 - Read Application
8.5.3 Extended Command 0x0307 - Modify Application Configuration
Table 9-10 - EMV Contact Application Slot 1 Data
Tag
Default Value
(Hex)
Max.
Length
Configurable
Tag Description
EMV Common Application Settings and Defaults
from section
84
A0 00 00 00 25 01 0x10
MagTek
Dedicated File (DF) Name
97
00 00 00
0x0F
MagTek
Default TDOL
9F01
00 00 00 00 00 01 0x06
MagTek
Acquirer Identifier
9F06
A0 00 00 00 25 01 0x10
MagTek
Application Identifier (AID) - terminal
9F09
00 01
0x02
MagTek
Application Version Number
9F1B
00 00 00 00
0x04
MagTek
Terminal Floor Limit
9F49
9F 37 04
0x0A
MagTek
Default DDOL
DFDF23 01
0x01
MagTek
Application Selection Indicator (ASI)
DF8120 00 00 00 00 00
0x05
MagTek
Terminal Action Code - Default
DF8121 00 00 00 00 00
0x05
MagTek
Terminal Action Code - Denial
DF8122 00 00 00 00 00
0x05
MagTek
Terminal Action Code - Online
DFDF10 00 00 00 00 00 00 0x06
MagTek
Threshold Value for Biased Random Selection
DFDF11 63
0x01
MagTek
Target Percentage to be used for Random
Selection (0 - 63 hex)
DFDF12 63
0x01
MagTek
Maximum Target Percentage to be used for
Biased Random Selection (0 - 63 hex)
DFDF67 01
0x01
MagTek
MSR Fallback Supported (Not Supported)
DFDF68 00
0x01
MagTek
PIN Bypass Supported (Not Supported)