1)
Move the fireplace into place.
2)
Install the outside air assembly.
3)
Install the floor protector. Refer to the section Hearth Extension Requirements and make sure the gap
between the fireplace and the hearth extension is sealed (refer to page 15).
OUTSIDE AIR INSTALLATION
(optional)
If an Outside Air Kit is to be installed observe the guidelines given in the section on Outside Air Kit
Requirements. Make a 4 ¼” (110 mm) hole in the outside wall of the house at the chosen location. From
outside, place the outside air register in the hole (open side down) and fasten the register to the wall with
screws as shown (SEE FIGURE 22). At each end, carefully pull back the insulation and the plastic cover
exposing the flexible duct. Place the flexible duct over the register tube and over the fireplaces outside air
connector 4” elbow located inside the bottom of the fireplace (SEE FIGURE 23).
Using aluminum tape, wrap the joint between the flexible duct and the air inlets. Carefully push the
insulation and on the outside register (SEE FIGURE 22) pull the plastic cover back over the duct. Using
aluminum tape, fasten the plastic cover in place. Only the insulation will go into the fireplace area on the
unit side.
MAGNUM ZC FIREPLACE INSTALLATION INSTRUCTION
OUTSIDE AIR INTAKE REGISTER
OUTSIDE AIR CONNECTOR IN UNIT
FIGURE 22
FIGURE 23
OPENING
DOWN
wall
Aluminum tape
Flexible duct
Insulation and plastic cover
Aluminum tape
Flexible duct
4” elbow located
under the unit.
Open the lower
grill to access.
Plastic
cover
Insulation
Magnum ZC
unit.
Screws