A large central lifting eye is located on the top of the
generator and the eye is connected to the frame of the
unit. Attach a sling or hook directly to the lifting eye only
if the devices are in good condition and the equipment
being used to raise the unit has sufficient capacity.
Approximate weights can be found on page 7. Always
remain aware of others around you when moving or lifting
the generator.
•
Check the engine oil level daily before starting engine.
•
DO NOT
start the generator if the oil level is low! The normal operating level for the engine oil is when oil
is
present on the crosshatch pattern of the dipstick. Add oil to the engine if it does not start or if oil is
not
present on the dipstick when tested.
•
DO NOT
overfill the crankcase.
•
Consult the engine OPERATION AND MAINTENANCE MANUAL for the proper grade of oil, including
special operating conditions such as a change in season or climate.
•
Service the generator more frequently when used in dusty areas.
LIFTING THE GENERATOR
ITEM DAILY
20
HRS.
50
HRS.
100
HRS.
300
HRS.
Check engine oil level
Change engine oil
*
Check air filter
Clean air filter
Replace air filter
Check and adjust spark plug
Replace spark plug
Clean muffler/spark arrester
Check and adjust idle speed
Check and adjust valve clearance
Clean combustion chamber
Clean fuel tank and filter
Check fuel tube
Visual walk around inspection
Every 500 hours
Every 2 years
Every 1 year
* After initial break-in, change the engine oil and filter. Oil change interval can then be extended to 100 hours.
MAINTENANCE SCHEDULE
DAILY MAINTENANCE CHECKS AND TIPS
The following maintenance schedule should be followed to ensure proper performance of the unit.
WARNING
DO NOT service the generator unless you have the proper tools and are mechanically proficient.
Improper repairs may result in equipment damage, serious personal injury, or death.
15