![Magnum MPG 3800C Operating & Parts Manual Download Page 9](http://html1.mh-extra.com/html/magnum/mpg-3800c/mpg-3800c_operating-and-parts-manual_3653960009.webp)
GROUND FAULT
SENSING MODULE
WARNING
TEST BEFORE EACH USE
SEE INSTRUCTIONS
RESET
RESET
P
O
W
E
R
F
A
U
L
T
A
B
C
D
E
F
G
H
MPG 3800
CONTROL PANEL COMPONENTS
A.
ENGINE START SWITCH:
This switch must be in the ON position to start the engine. To stop the engine,
place switch in OFF position.
B.
AUTO IDLE SWITCH:
When this switch is engaged, the engine speed will return to idle whenever the
generator is not under load.
C.
VOLTAGE SWITCH:
This switch changes voltage on the L14-30R outlet from 120V to 240V.
D.
MAIN CIRCUIT BREAKER:
This unit contains a 16A circuit breaker.
E.
GFCI TEST MODULE:
This module is the ground fault circuit interrupter to protect all electrical outlets.
F.
120/240V TWIST-LOCK CONVENIENCE OUTLET:
This L14-30R outlet is used to connect additional loads or
equipment to the generator.
G.
120V TWIST-LOCK CONVENIENCE OUTLET:
This L5-30R outlet is used to connect additional loads or
equipment to the generator.
H.
120V DUPLEX CONVENIENCE OUTLETS:
These 120V outlets are used to connect additional loads or
equipment to the generator.
9