Controlling Instructions 

1 Working Mode 

n

Manual Mode: The user can adjusts the fan speed switch manually (high, middle and low);

n

Intelligent Mode: According to the setting value of PM2.5 or CO2, it can switch the fan speed automatically.

n

Mute Mode: Operation at low speed;

n

Periods Mode: The user can set different fan speed in four periods within 24 hours (00: 00 ~ 06: 00, 06: 00 ~
12: 00, 12: 00 ~ 18: 00, 18: 00 ~ 24: 00)

2 Key’s Function 

n

Power-on Key(long press for 2s);

n

Fan speed key, switch the fan speed(high, medium, low), the default is low speed when power on;

n

Confirmation key (use in confirm operating or standby mode setting);

n

Function key (adjust the fresh air and exhaust air). There are three status: “exhaust air”, “fresh air”, and

“fresh air + exhaust air”; Default is “fresh air + exhaust air” 

n

Mode key (WIFI key also). There are four modes: manual, intelligent, mute, and periods. Default is

manual mode. Long press till the buzzer off then is WIFI status. 

3 Operation Instructions 

1 Switch on and off: press and hold the 

for 2s to turn on or off. When it’s the switch off status, all readings 

and output will off. 

2 Switch the operating mode: Press the 

to change the operating mode. The working mode is cyclically 

switched in the four states of "periods-intelligent-manual-mute". After the mode setting is completed, press the 

the screen returns to the data detection interface. 

3 Time period mode: Press the operating mode key and the confirmation key, the user can set the fan speed by 

for 4 time periods per day (00: 00 ~ 06: 00, 06: 00 ~ 12: 00, 12: 00 ~ 18: 00, 18: 00 ~ 24:00). 

Note

This time period used for setting fan speed 

For example

Setting      Monday 

00:00 

Low 

06:00 

Medium 

12:00 

High 

18:00 

Low 

By this logic, the fan speed be set to low speed from 00:00 to 06:00; and it be set to medium speed from 06:00 

to 12:00, high speed from 12:00 to 18:00. 

4 Intelligent Mode

 

Summary of Contents for M9-IAQS

Page 1: ...Compatible with push button and touch screen operation Using standard 86 box size thickness 24mm PM2 5 CO2 RH T etc multiple sensors can be optionally selected With fresh air control function three l...

Page 2: ...530 25 2 50 10 RH CO2 Measurement accuracy 50ppm 5 of reading 0 50 Temperature Measurement accuracy 1 Humidity Measurement accuracy 8 RH PM Response time T90 8s CO2 Response time T90 120s Working cond...

Page 3: ...ions and Interface Definition 1 Dimensions Unit mm tolerance 0 2 mm 2 Pin definition No Pin Description 1 TA Communication port RS485_TA 2 TB Communication port RS485_TB 3 12V Power input 12VDC 24VDC...

Page 4: ...agnumFirst com 5 11 UI Interface Description Parameter Range corresponding to color LIST Gas Level Range Color PM2 5 g m Good 0 75 Just so so 75 115 Bad 115 CO2 ppm Good 0 600 Just so so 600 1000 Bad...

Page 5: ...o There are four modes manual intelligent mute and periods Default is manual mode Long press till the buzzer off then is WIFI status 3 Operation Instructions 1 Switch on and off press and hold the for...

Page 6: ...de The fan speed switched by the user Despite the time period and air quality The fan speed can be adjusted by the The adjustment range is low medium high 6 Mute mode The fan runs at low speed and can...

Page 7: ...ecting Cable connect the corresponding cable to the controller s RS485 interface according to the interface definition as shown below Step 3 Match the two holes in the controller with the hooks in the...

Page 8: ...r or rub it against hard objects during use otherwise it may cause damage to the controller s external light and damage Do not place the controller in a dusty environment to avoid dust accumulation in...

Page 9: ...Sending by controller is fixed as 11H Length Length of frame bytes data length 2 including CMD IP DATA Command Command is fixed as 55H Address Controller address is 1 254 default is 01H Data Data of...

Page 10: ...tration DF6 DF7 0 5000 ppm Indoor Temperature DF8 DF9 0 600 Corresponding value 100 10 C 10 0 50 0 one decimal place is reserved Indoor Humidity DF10 0 95 0 95 Indoor HCHO Concentration DF11 DF12 Rese...