11
Mounting Rails & Extension Table
With the extension wings properly aligned, the
rail and fence assembly can now be mounted to
the saw. Refer to the
Rip Fence
Owner's Manual
for mounting instructions for the rails, fence
Electrical Connections
A qualified electrician must
complete all electrical connections! Failure
to comply may result in serious injury!
and optional wooden extension table.
Switch Installation
Referring to Figure 9:
Attaching the Switch Bracket Assembly
Tool
: 10PP :UHQFK
1. /RRVHQ KH[ 1XW DQG /RFN :DVKHU IURP WKH
6ZLWFK 3ODWH &DUULQJH %ROW.
2.3ODFH VZLWFK EUDFNHW DVVHPEO\ LQWR FDELQHW
IURQW /HIW VLGH.
3.$OLJQ WKH VZLWFK DQG WLJKWHQ DOO KDUGZDUH.
Figure 9
The machine must be
properly grounded while in use to protect the
operator from electric shock! Failure to
comply may result in serious injury!
If a plug is provided with your machine,
do not
modify the plug. If it will not fit your electrical
receptacle, have a qualified electrician install the
proper connections to meet all electrical codes.
1. Disconnect the machine from the power
source, (unplug).
2. Open the saw cabinet door.
3. Remove the cover from the motor junction
box.
4. Change wires following the diagram on the
inside of the cover.
5. Replace the cover and close the cabinet
door.
Confirm power at the site is the same as the saw
before making any electrical connections.
Review the electrical schematics on page 29-30.
The on and off switch is
thermally protected
. If
the saw motor is overloaded, or a momentary
interruption of electrical current is sensed, the
saw will shut off. Allow a few minutes for the
saw to cool down and
reset by pushing the off
button
.
Using extension cords can cause a loss in
power to your machine. It is best if the saw is
plugged directly into an outlet on a dedicated
circuit.
Summary of Contents for MI-51350
Page 1: ...MODEL NO MI 51350 MI 51453 OPERATING MANUAL...
Page 8: ...8 G H J H C A...
Page 18: ...18 Table and Cabinet Assembly Flat FrontType...
Page 21: ...21 Motor and Trunnion Assembly Breakdown Left tilt...
Page 26: ...26 Blade Guard Assembly...
Page 28: ...28 Wiring Diagrams 3HP 230V 1Phase A1 A2...