Magnum Energy MM-R Owner'S Manual Download Page 3

© 

2010 Magnum Energy, Inc

.

Disclaimer of Liability

The use of this manual and the conditions or methods of installation, 

operation, use, and maintenance of the MM-R and MM-RC Remote 

Controls are beyond the control of Magnum Energy, Inc. Therefore, 

this company assumes no responsibility and expressly disclaims 

any liability for loss, damage, or expense whether direct, indirect, 

consequential, or incidental that may arise out of or be in anyway 

connected with such installation, operation, use, or maintenance.
Due to continuous improvements and product updates, the images 

shown in this manual may not exactly match the unit purchased.

Restrictions on Use

The MM-R and MM-RC Remote Controls shall not be used in 

connection with life support systems, life saving or other medical 

equipment or devices. Use at your own risk.

Contact Information

Magnum Energy, Inc.

2211 West Casino Rd.

Everett, WA 98204

phone: (425) 353-8833/fax: (425) 353-8390

web: www.magnumenergy.com

Product Safety Instructions

Read and follow all instructions and safety information contained in 

this manual before installing or using this product.

• All electrical work must be performed in accordance with local, 

state, and federal electrical codes.
• This product is designed for indoor/compartment installation. It 

must not be exposed to rain, snow, moisture, or liquids of any type.
• Use insulated tools to reduce the chance of electrical shock or ac-

cidental short circuits.
• Always verify proper wiring prior to connecting the remote.

Safety Symbols

To reduce the risk of electrical shock, 

fi

 re, or other safety hazard, 

the following safety symbols have been placed throughout this 

manual to indicate dangerous and important safety instructions.

WARNING:

 Indicates that failure to take a speci

fi

 ed 

action could result in physical harm to the user.

CAUTION:

 This symbol indicates that failure to 

take a speci

fi

 ed action could result in damage to the 

equipment.

Info:

 This symbol indicates information that emphasizes 

or supplements important points of the main text.

i

Summary of Contents for MM-R

Page 1: ...Owner s Manual MM R and M RC Remote Controls...

Page 2: ...2010 Magnum Energy Inc...

Page 3: ...33 fax 425 353 8390 web www magnumenergy com Product Safety Instructions Read and follow all instructions and safety information contained in this manual before installing or using this product All el...

Page 4: ...6 Operation 7 ON OFF Switch 7 Monitoring the LED Indicators 8 MM R and MM RC Remotes 8 MM RC Remote Only 9 4 0 Warranty and Service Information 11 List of Figures Figure 1 MM R and MM RC Remote Contr...

Page 5: ...ch The unit comes with 25 cable This remote is for the MM612 model requires serial number L1 201 or higher MM RC Provides six LED indicators for inverter and charger sta tus and includes a remote ON O...

Page 6: ...the cable route from the remote to the inverter before you do any cutting or drilling to ensure there are no obstructions that can t be overcome Allow ample room to access the ON OFF switch view the...

Page 7: ...s DO NOT cut the opening too big to ensure there are no openings around the display and that there is enough material for the screws to secure the display Remove any wall insulation if applicable that...

Page 8: ...reak the appropriate tab on the mounting ring 4 Pull the cable through the mounting ring and place the ring side with the removed tab over the communication cable against the wall 5 Position the mount...

Page 9: ...2010 Magnum Energy Inc Figure 5 Remote Display Dimensions Figure 6 Mounting Ring Dimensions 2 0 Installation 5 BULK ABSORB FLOAT INVERT AC IN FAULT ON OFF Side Front Side Front...

Page 10: ...ner s Manual to help clear the fault condition Factory Default Settings Your MM MM AE Series inverter has many functions that have changeable settings These settings are preset and loaded by the inver...

Page 11: ...r feature this switch can also be used to disable the charger Charger Standby so that all the incoming power can be used exclusively for the AC loads To turn the charger off press and hold the ON OFF...

Page 12: ...rgy from the battery to supply AC power to the loads connected to the inverter and AC IN LED indicator is On solid The inverter is in Standby The external AC power utility or generator connected to th...

Page 13: ...n above acceptable limits This is caused by loads too great for the inverter to operate continuously or by a lack of ventilation to the inverter When the unit has cooled it will automatically reset an...

Page 14: ...ces charge rate to help stabilize the incoming AC voltage Off charger is not in Absorption Charge mode FLOAT green On solid Float Charging at the end of the absorb charging time the charger reduces th...

Page 15: ...repair determined by the price paid by the original purchaser Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the...

Page 16: ...2010 Magnum Energy Inc Magnum Energy Inc 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www magnumenergy com PN 64 00012 Rev A...

Reviews: