Part Number 64-0015
Page 2 of 2
Supplement to ME and MS Series Operator’s Manual
continued
ME2000-20B AC Wiring
30
20
20
CB2
OUTPUT 2
CB3
INPUT 30 A
Engineered and Manufactured in the U.S.A.
Serial Number
Model: ME2000 Inverter/Charger
Inverter Operation:
Continuous output power: 2000 Watts @ 25
°C
Peak output current 33.0AAC, 10 sec surge (unregulated)
Output provided with integral protection against overload
DC Input: 10.0-15.5VDC
Continuous input current: 190A @ 12.6VDC
Charger Operation:
Continuous Charger current: 100ADC @ 11-14VDC
AC Input: 120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16 amps of 120VAC)
Power Factor: @ 10% to 100% charge > .95
Magnum Energy Inc.
1111 80th St S.W. Suite 250
Everett, Wa. 98203
N1-00001
Q
tr 1
2
3
4
Y
e
a
r 0
6
0
7
0
8
0
9
Date Code -
AC Input: 120VAC/60Hz @ 30 Amps Max with a 12.6VDC Input
CB1
OUTPUT 1
AC
Main
Panel
AC IN
(30A breaker)
AC OUT
AC HOT IN
BLACK
WHITE
GREEN
WHITE w/BLACK
BLUE
ORANGE
AC NEU IN
AC GROUND
AC HOT 1 OUT
AC NEU
OUT (x2)
AC HOT 2 OUT
AC outlets
(20A circuits)
20A output breakers
AC GROUND (x2)
Figure 2, AC Wiring for the ME2000-20B
Specifications:
Model
ME2000 (-20B)
MS2000
Inverter Operation
Continuous Output Power:
2000 watts @ 25°C
2000 watts @ 25°C
Continuous Input current:
190A @ 12.6VDC
225A @ 12.6VDC
Peak Output Current:
33.0 AAC, 10 sec surge
(unregulated)
29.0 AAC, 10 sec surge
(unregulated)
DC Input:
10-16 VDC
10-17 VDC
Charger Operation
Continuous Charger Current:
100ADC @ 11-14VDC
100ADC @ 11-14VDC
AC Input: 120VAC/60Hz @ 30 Amps Max
120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16
amps of 120VAC)
(Charger can use up to 16 amps
of 120VAC)
Power Factor:
>0.95
>0.95