background image

Part Number 64-0015 

Page 2 of 2 

 

 

 

Supplement to ME and MS Series Operator’s Manual

 

continued

 

 

 

ME2000-20B AC Wiring 

 

30

20

20

     CB2
OUTPUT 2

      CB3
INPUT 30 A

Engineered and Manufactured in the U.S.A.

Serial Number

Model: ME2000 Inverter/Charger

Inverter Operation:

Continuous output power: 2000 Watts @ 25

°C

Peak output current 33.0AAC, 10 sec surge (unregulated)
Output provided with integral protection against overload
DC Input: 10.0-15.5VDC
Continuous input current: 190A @ 12.6VDC

Charger Operation:

Continuous Charger current: 100ADC @ 11-14VDC
AC Input: 120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16 amps of 120VAC)
Power Factor:  @ 10% to 100% charge > .95

Magnum Energy Inc.
1111 80th St S.W. Suite 250
Everett, Wa. 98203

N1-00001

 Q

tr   1

     2

     3

     4

     Y

e

a

r  0

6

    0

7

    0

8

   0

9

 Date Code -

AC Input: 120VAC/60Hz @ 30 Amps Max with a 12.6VDC Input

     CB1
OUTPUT 1

AC

Main 

Panel

AC IN

(30A breaker)

AC OUT

AC HOT IN

BLACK

WHITE

GREEN

WHITE w/BLACK

BLUE

ORANGE

AC NEU IN

AC GROUND

AC HOT 1 OUT

AC NEU 

OUT (x2)

AC HOT 2 OUT

AC outlets

(20A circuits)

20A output breakers

AC GROUND (x2)

 

 

Figure 2, AC Wiring for the ME2000-20B 

 

 

Specifications: 

Model 

ME2000 (-20B) 

MS2000 

 

Inverter Operation 

Continuous Output Power: 

2000 watts @ 25°C 

2000 watts @ 25°C 

Continuous Input current: 

190A @ 12.6VDC 

225A @ 12.6VDC 

Peak Output Current: 

33.0 AAC, 10 sec surge 

(unregulated) 

29.0 AAC, 10 sec surge 

(unregulated) 

DC Input: 

10-16 VDC 

10-17 VDC 

 

Charger Operation 

Continuous Charger Current: 

100ADC @ 11-14VDC 

100ADC @ 11-14VDC 

AC Input:  120VAC/60Hz @ 30 Amps Max 

120VAC/60Hz @ 30 Amps Max 

 

(Charger can use up to 16 

amps of 120VAC) 

(Charger can use up to 16 amps 

of 120VAC) 

Power Factor: 

>0.95  

>0.95 

 

Reviews: