ME-PT2 Instruction Sheet

© 2014 Magnum Energy, Inc.

Figure 4, ME-PT2 to ME-AGS-S Installation

                                               

Dometic Comfort Control Center™

ME-PT2 can be used in conjunction with the Dometic / Duo-Therm kit 

(3109226.005) 

and

Dometic Comfort Control Center™ to connect the t

-stat output of the A/C directly to the AGS. 

This allows the AGS to start on demand from the A/C for either heat (heat pump only) or cool.
1. Connect the two wires from the ME-PT2 adapter to the Duo-Therm per kit instructions.
    Make sure to set the #8 DIP switch on the Duo-Therm control box per instructions.
2. 

Follow Comfort Control Center™ instructions for proper zones

, heat, cool and AGS settings.

3. The ME-AGS-

S will now start on demand from the Comfort Control Center™

.

External

Maintain Switch

External

Momentary Switch

One time push (or 
close):
Gen runs for the 
duration of the RUN 
TIME HOURS period.

ME-AGS-S

options

ON

OFF

Switch set to ON: gen 
continues to run.

Switch set to OFF: gen 
stops after current RUN 
TIME HOURS cycle has 
been satisfied.

Air Conditioner 

(wire to electronic 

  control box)

PT2-AGS

Phone Splitter

(6-conductor)

Remote Switch

(with Temp Sensor opened)

AUTO GEN STA RT

ENABLE

OFF

TEST

ME-PT2 Instruction Sheet

Part Number: 64-0026 Rev D 

1

Magnum Energy, Inc.

2211 West Casino Road

Everett, WA, USA 98204

www.magnumenergy.com

Introduction

The  ME-PT2  (pigtail  two-wire)  adapter  is  designed  to  be  connected  to 
Magnum’s  Auto  Generator  Start  (AGS)  controller  to  allow  a  connected 
generator  to  be  started  by  an  external  switching  device.  This  is  useful  in 
applications where there is a requirement to conveniently and automatically 
turn the generator on/off externally through a manually controlled switch, or 
from an automatically controlled switching device.

This adapter has two pigtail wires and when connected together they cause 
the AGS controller to start and run the connected generator.

Info:

 The high temperature start feature is not available when using 

the ME-PT2. However, the low battery voltage start feature is still 
available.

Installation/Setup – ME-AGS-N (Network Version)

The following pertains to the ME-PT2 when connected to the ME-AGS.

Info:

  Refer  to  the  ME-AGS-N  Owner’s  Manual  (64-0039)  for 

installation, setup and operation of the ME-AGS-N; and the ME-RC 
(64-0003) or ME-ARC (64-0030) owner’s manuals for information 
on selecting/adjusting settings.

Installation

To install the ME-PT2, refer to Figure 1 and the steps below:

1.  Connect  the  two  white  wires  on  the  ME-PT2  adapter  to  a  two-contact 

external switching device (i.e., switch).

2.  Plug the ME-PT2 adapter into the REMOTE (purple) port on the ME-AGS-N.

Info:

  The  remote  temperature  sensor  that  comes  with  the 

ME-AGS-N  (normally  plugged  into  the  AGS’s  REMOTE  port)  is  not 
used when the ME-PT2 is connected.

Setup

When  using  the  ME-PT2  with  the  ME-AGS-N,  confi gure  the  ME-RC  (or  ME-
ARC) to allow the AGS to accept the external input from the ME-PT2.

• 

Find the temperature start setting—depending on your remote: ME-RC 
(under 

AGS/04 Start Temp F

 menu), or ME-ARC (under 

SETUP/04E Gen 

Run Temp/Start

 menu). Then, select the 

Start=Ext Input

 setting.

ME-PT2 to ME-AGS-N Operation

The type of external switch (i.e., “momentary” or “maintain”) connected to 
the ME-PT2 adapter determines how long the generator can run. 

ME-RC

A. 

Using a momentary type switch:

 Pressing the switch causes the generator 

to run for the duration of a full run time cycle (as set in the 

AGS/03 Run Time 

Hour

 menu), and then stop.

B. 

Using  a  maintain  type  switch:

  If  the  switch  is  set  to  ON,  the  generator 

continues to run until the switch is set to OFF. Once the switch is set to OFF, 
the generator will continue to run for the remaining duration of the current 
run time cycle (as set in the 

AGS/03 Run Time Hour

 menu), and then stop.  