©2009 Magnum Energy Inc.
33
Operation
LED
Status
Meaning
INV
(green)
OFF
1. Inverter is disabled; or 2. Remote is in Power
Saver mode - press any button to activate LED’s
ON
Inverter is enabled - 1. Supplying AC power
on the output; or 2. In standby (if both INV
and CHG LED’s are on); the inverter will
automatically supply AC power to the loads if
shore or generator power is lost.
BLINKING
Inverter is in search mode (the AC load is below
the
SETUP: 01 Search Watts
setting).
FAULT
(red)
OFF
Normal operation.
ON
A fault conditionhas been detected, check the
LCD displayto
fi
nd and correct the cause.
5.3.4 LED Indicator Guide
The remote provides the following LED’s; use them along with the LCD display
to determine the operating status.
Table 5.1, LED Indicator Guide