Testing the CSW-TS15 Transfer Switch
To test your CSW-TS15 transfer switch:
1. Turn the AC source (utility power or generator) and the CSW1012 inverter
ON. Verify that 120VAC is available at the AC output.
2. Turn off the AC source by switching the 15A branch circuit breaker OFF.
Verify that 120VAC remains at the AC output.
3. Turn OFF the CSW1012 inverter. Verify that there is no AC voltage at the
AC output.
4. If all steps above are successful, the transfer switch is functioning prop-
erly. If any of the above steps are unsuccessful, repeat the installation
steps from page 1.
CSW-TS15 Specifi cations
Figure 2, CSW-TS15 Transfer Switch (with wiring cover removed)
Line
Line
Neutral
Neutral
Ground
Ground
AC Output
(Load)
AC Input 2
(Utility)
AC Input 1
(Inverter)
AC Input 1 (Inverter)
Pure Sinewave 120VAC/60Hz (15A max)
AC Input 2 (Utility)
120VAC/60Hz (15A max)
AC Output (Load)
120VAC/60Hz (15A max)
Low Transfer Voltage
90VAC
Transfer Time
80mSec
Environmental Condition
TYPE 1 (indoor only)
Load Current
≤15 Amps continuous; Tungsten fi lament load
not to exceed 30% of switch rating (4.5 AAC)
Compliance
UL STD 1008/CSA STD C22.2 No.178-1,
FCC Class B
Unit Dimensions 6.6 x 4.3 x 1.8 (inches) / 168 x 110 x 46 (mm)
Ship Dimensions 9.6 x 7.3 x 2.4 (inches) / 243 x 186 x 62 (mm)
Unit Weight
1.8 lbs (0.8kg)
Ship Weight
2.2 lbs (1.0kg)
Note: Specifi cations are subject to change without notice.