3.0 Operation
3.3.1 LED
Indicators
The LED indicators on the front display panel are used to indicate the
inverter’s status. Use Table 3-1 to determine the inverter status.
Table 3-1, Display Functions/Statuses
Status LED Display LED Display
Function/Status
Green
(solid)
Green
12.5
By-Pass mode. Display shows
battery voltage in DC volts.
Amber
(solid)
Green
12.5
Inverter mode. Inverter running
and display shows battery
voltage in DC volts.
Amber
0.80
Inverte) mode. Inverter is
running, and display shows
output power in kW (800W as
shown). The Select button has to
be pressed.
Amber
(
fl
ashing)
Inverter mode. AC input is detected and the unit will
switch to By-Pass mode within 20 seconds.
Red (solid)
OFF
E01-E12 Unit has shut down. Display
shows an error code (see error
code reference chart below).
3.3.2 Understanding the Power and Select Buttons
A beep sound occurs every time the Power or Select button is activated (i.e.,
pressed for 1 second).
Power button
–
Turns the inverter On/Off during Inverter mode. Press and
hold it for 1 second to turn the inverter either ON or OFF.
Note: The Power button can be used to turn the AC output off during AC By-
Pass mode with PS4 setting—without the need to disconnect the AC input as
per the PS1 setting. See Table 3-2 or Section 3.3.3.
Select button
– Used to check the inverter settings. Press the Select button
several times to scroll down to view the inverter’s present setting.
Figure 3-1, Display Panel
3.3
Display Panel Operation
This section provides information on the display panel (Figure 1-1, Item 5).