background image

Installation and Operating Manual

Solitel

Vibrating

Rod Level

Switch

Summary of Contents for Solitel

Page 1: ...Installation and Operating Manual Solitel Vibrating Rod Level Switch...

Page 2: ...rking with electrostatic sensitive components This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference a...

Page 3: ...Unpacking Unpack the instrument carefully Make sure all compo nents have been removed from the packing material Inspect all components for damage and report any concealed damage to the carrier within...

Page 4: ...the specifications for bending force F torque M and pull force F as indicated below See Figure 4 Standard F 100 pounds 445 N M 63 foot pounds 85 Nm Extended Rigid M 63 foot pounds 85 Nm When using an...

Page 5: ...terminal marked L1 and the neutral to terminal L2 N There is no con nection to the center terminal b 24 VDC Connect wires to terminals and There is no connection to the center terminal 4 To ensure op...

Page 6: ...of rotation Do not rotate past the stops NOTE If the adjustment is too sensitive the switch may detect even slight residue of material rather than level Prior to installation it is recommended that t...

Page 7: ...asured the problem is with the sensor NOTE The probe and electronics must be matched to ensure proper operation Use the following procedure to match the electronics and the vibrating probe 1 Connect t...

Page 8: ...robe are now matched 3 2 Agency Approvals 3 2 1 CSA Model Approval VXX D1BX XXX Class I Div 2 Groups A B C D Class II Div 1 Groups E F G Type 4X 3 3 Replacement Parts Item Description Part Number 1 Ba...

Page 9: ...ance 40 to 320 F 40 C to 160 C Ambient electronics temp 40 to 140 F see chart at left 40 to 60 C Relative humidity 98 Maximum process pressure 360 psig Minimum Density 50 oz ft3 or 0 05 gm cm3 Materia...

Page 10: ...9 3 44 87 Rotation clearance 11 2 NPT process connection 3 4 NPT Conduit connection 2 75 69 4 63 117 Dia 3 63 92 3 4 NPT plugged 1 5 38 3 4 2 Physical Extended Rigid Probe 1 73 44 Dia 6 34 161 Inserti...

Page 11: ...ngth in inches H Standard rigid 8 25 21 cm length R Extended rigid 0 110 VAC 2 24 VDC DESIGN TYPE PROBE TYPE INPUT VOLTAGE Design type code 1 or 2 with probe type code R Code 000 fixed length of 8 25...

Page 12: ...laced In such cases credit for the materials returned will be determined on the basis of the applicability of our warranty No claims for misapplication labor direct or consequen tial damage will be al...