32
46-624 Series 3 Liquid Level Switches ASME B31.1 Construction
5.4.2 Flanged Cage Models
Switch
Description
Maximum
Supply
Pressure
Maximum
Process
Temperature
Bleed
Orifice
Diameter
All Models
except: B3F, g3F,
K3F & Z3F
with 600 lb.
Head Flanges
Models
B3F, g3F,
K3F & Z3F
with 600 & 900 lb.
Head Flanges
psig
bar
° F
° C
inches
mm
NEMA 1
NEMA 1
Series J
Bleed Type
100
7
400
204
.063
1.6
JGH
JGF
50
4
400
204
.094
2.3
JHH
JHF
60
4
700
371
.055
1.3
JJH
JJF
Series K
Non-Bleed
100
7
400
204
—
—
—
KOF
40
3
400
204
—
—
KOH
—
MODEL NUMBER CODE
CAgE SIZE AND TANK CONNECTION TyPE
P
Carbon steel chamber, 316L stainless steel float, 400 stainless steel sleeve, ASME B31.1 Construction
MATERIALS OF CONSTRUCTION
PNEUMATIC SWITCH MECHANISM AND ENCLOSURE
Model
Code
Head
Flange
ANSI Class
Minimum
S.g.
➀
gravity
➀
Pressure Rating
➁
psig @ ° F
bar @ ° C
1
100
550
750
800
∆
38
288
399
427
∆
B3F
150#
0.78
285
155
95
80
19.6
10.7
6.5
5.5
300#
0.66
740
588
505
410
51.0
39.6
34.8
28.3
600#
0.66
1000
875
805
795
68.9
60.3
55.5
54.8
G3F
150#
0.41
285
155
95
80
19.6
10.7
6.5
5.5
300#
0.55
740
588
505
410
51.0
45.0
41.4
28.3
600#
0.70
1000
875
805
795
68.9
60.3
55.5
54.8
K3F
600#
0.60
1480
1170
1015
825
102.0
80.7
70.0
56.9
Z3F
600#
0.67
1480
1170
1015
825
102.0
80.7
70.0
56.9
900#
1875
1875
1426
1184
129.3
129.3
98.3
81.7
Connection
Type
Connection Size
C/C
1"
1
1
⁄
2
"
2"
ANSI Head Flange Rating (lbs.)
150
300
600
900
150
300
600
900
150
300
600
900
Threaded
Std.
B20
B60
B80
B40
C20
C60
C80
C40
D20
D60
D80
D40
Socket Weld
Std.
B30
B70
B90
B50
C30
C70
C90
C50
D30
D70
D90
D50
Flanged
Upper Side/
Bottom
Std.
N30
N40
—
—
P30
P40
—
—
Q30
Q40
—
—
14"
N34
N44
N54
N64
P34
P44
P54
P64
Q34
Q44
Q54
Q64
16"
—
—
N56
N66
—
—
P56
P66
—
—
Q56
Q66
18"
—
—
N58
—
—
—
P58
—
—
—
Q58
—
Flanged
Side/Side
Std.
S30
S40
—
—
T30
T40
—
—
V30
V40
—
—
14"
S34
S44
S54
S64
T34
T44
T54
T64
V34
V44
V54
V64
16"
—
—
S56
S66
—
—
T56
T66
—
—
V56
V66
18"
—
—
S58
—
—
—
T56
—
—
—
Q58
—
➃
➄
➃
➄
¬
¬
➀
Minimum specific gravity ratings apply to single stage units only. Consult
factory for two or three stage units.
➁
Models are limited to maximum temperature rating of selected switch
mechanism.
¬
Models Z3F & K3F contain 7–17 ph stainless steel floats.
➃
Codes for a 16 inch center to center dimension are applicable to models
G3F and Z3F with 600# flanges only.
➄
Codes for an 18-inch center to center dimension are applicable to K3F
model only.
➅
Process temperature based on +100° F (+38° C) ambient.
∆
For models built to ASME B31.1 in applications over +750° F (+399°C),
100% radiographic examination is required. Consult factory for pricing.
➇
HS switches can be used with only materials of construction code 1 on all
models with 600# or 900# ANSI rating.