background image

 

P.O. Box 13615 
Milwaukee, WI 53213 
Toll-Free Phone 800.288.8178 
Toll-Free Fax 800.298.3503 

N49 W13650 Campbell Drive 
Menomonee Falls, WI 53051 
Phone 262.783.3500 
Fax 262.783.3510 

  

www.magnetek.com 

 

Instruction Sheet No. 126-11170 R0 

 

SBU-BzS-B Buzzer Switch

Instruction Sheet 

 

Lean the fixed contactor base to 45° and insert the casing. 

 

Rotate the fixed contactor base clockwise to 45° (see Figure 2). 

 

Use the round crimp terminals. 

 

Tighten the M4 terminal screws to a tightening torque of 12 – 14 kgf.cm (1.2 – 1.4 N.m). 

 

Removing the Buzzer Switch 

Primary Method 

 

Remove the terminal screws. 

 Remove 

the 

wiring. 

 

Rotate the fixed contactor base counterclockwise to 45°. 

 

Pull the fixed contactor base. 

 

Remove the hexagon nut and spring washer. 

 

Pull the button cap and casing from the front housing. 

 

Figure 3: Primary Buzzer Removal Method 

Alternate Method 

 

Alternately, insert a flathead screwdriver into the slit of the cover, and the pawl of the cover is deformed. 

 

Rotate the fixed contactor base counterclockwise to 45°, and the fixed contactor base is drawn out. 

 

Remove the hexagon nut and spring washer. 

 

Pull the button cap and casing from the front housing. 

 

Figure 4: Alternate Buzzer Removal Method 

Operation

 

Do not expose the buzzer switch to excessive shocks and vibrations. Otherwise, the switch may become deformed or 
damaged, causing malfunctions or operation errors. 